Dispersive liquid-liquid microextraction based on the solidification of floating organic droplet for the determination of polychlorinated biphenyls in aqueous samples

被引:64
作者
Dai, Liping [1 ]
Cheng, Jing [1 ]
Matsadiq, Guzalnur [1 ]
Liu, Lu [1 ]
Li, Jun-Kai [2 ]
机构
[1] Cent China Normal Univ, Coll Chem, Key Lab Pesticide & Chem Biol, Minist Educ, Wuhan 430079, Peoples R China
[2] Yangtze Univ, Sch Agr, Jinzhou 434025, Peoples R China
基金
中国国家自然科学基金;
关键词
Polychlorinated biphenyls; Floating organic droplet; 1-Undecanol; Gas chromatography; Water analysis; SOLID-PHASE-MICROEXTRACTION; CHROMATOGRAPHY-MASS-SPECTROMETRY; SOLVENT BAR MICROEXTRACTION; ELECTRON-CAPTURE DETECTION; GAS-CHROMATOGRAPHY; WATER SAMPLES; ORGANOPHOSPHORUS PESTICIDES; ORGANOCHLORINE PESTICIDES; PHTHALATE-ESTERS; EXTRACTION;
D O I
10.1016/j.aca.2010.06.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the proposed method, an extraction solvent with a lower toxicity and density than the solvents typically used in dispersive liquid-liquid microextraction was used to extract seven polychlorinated biphenyls (PCBs) from aqueous samples. Due to the density and melting point of the extraction solvent, the extract which forms a layer on top of aqueous sample can be collected by solidifying it at low temperatures, which form a layer on top of the aqueous sample. Furthermore, the solidified phase can be easily removed from the aqueous phase. Based on preliminary studies, 1-undecanol was selected as the extraction solvent, and a series of parameters that affect the extraction efficiency were systematically investigated. Under the optimized conditions, enrichment factors for PCBs ranged between 494 and 606. Based on a signal-to-noise ratio of 3, the limit of detection for the method ranged between 3.3 and 5.4 ng L-1. Good linearity, reproducibility and recovery were also obtained. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:201 / 205
页数:5
相关论文
共 34 条
[1]   Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector [J].
Ahmadi, F ;
Assadi, Y ;
Hosseini, SMRM ;
Rezaee, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :307-312
[2]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[3]   MICROEXTRACTION OF SELECTED POLYCHLORINATED BIPHENYL CONGENERS AND DICHLORODIPHENYLTRICHLOROETHANES FROM ENVIRONMENTAL WATER AND ANALYSIS BY GAS-CHROMATOGRAPHY - ELECTRON-CAPTURE DETECTOR [J].
BOURGEOIS, DJ ;
DEVEAU, P ;
MALLET, VN .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1995, 59 (01) :15-24
[4]   Simultaneous analysis of polychlorinated biphenyls and organochlorine pesticides in water by headspace solid-phase microextraction with gas chromatography-tandem mass spectrometry [J].
Derouiche, Abdelkader ;
Driss, Mohamed Ridha ;
Morizur, Jean-Pierre ;
Taphanel, Marie-Helene .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1138 (1-2) :231-243
[5]   Development of dispersive liquid-liquid microextraction combined with gas chromatography-mass spectrometry as a simple, rapid and highly sensitive method for the determination of phthalate esters in water samples [J].
Farahani, Hadi ;
Norouzi, Parviz ;
Dinarvand, Rassoul ;
Ganjali, Mohammad Reza .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (02) :105-112
[6]   Optimization of dispersive liquid-liquid microextraction of copper (II) by atomic absorption spectrometry as its oxinate chelate:: Application to determination of copper in different water samples [J].
Farajzadeh, Mir Ali ;
Bahram, Morteza ;
Mehr, Behzad Ghorbani ;
Jonsson, Jan Ake .
TALANTA, 2008, 75 (03) :832-840
[7]   Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants [J].
Farajzadeh, Mir Ali ;
Bahram, Morteza ;
Jonsson, Jan Ake .
ANALYTICA CHIMICA ACTA, 2007, 591 (01) :69-79
[8]   Solid-Phase-Microextraction Measurement of 62 Polychlorinated Biphenyl Congeners in Milliliter Sediment Pore Water Samples and Determination of KDOC Values [J].
Hawthorne, Steven B. ;
Grabanski, Carol B. ;
Miller, David J. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :6936-6943
[9]   Determination of organochlorine pesticides in water using solvent cooling assisted dynamic hollow-fiber-supported headspace liquid-phase microextraction [J].
Huang, Shih-Pin ;
Huang, Shang-Da .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1176 (1-2) :19-25
[10]   Solvent bar microextraction [J].
Jiang, XM ;
Lee, HK .
ANALYTICAL CHEMISTRY, 2004, 76 (18) :5591-5596