CT-Defined Prosthesis-Patient Mismatch Downgrades Frequency and Severity, and Demonstrates No Association With Adverse Outcomes After Transcatheter Aortic Valve Replacement

被引:46
作者
Mooney, John [1 ]
Sellers, Stephanie L. [1 ]
Blanke, Phillip [1 ]
Pibarot, Philippe [2 ]
Hahn, Rebecca T. [3 ]
Dvir, Danny [4 ]
Douglas, Pamela S. [5 ]
Weissman, Neil J. [6 ]
Kodali, Susheel K. [3 ]
Thourani, Vinod H. [7 ]
Jilaihawi, Hasan [8 ]
Khalique, Omar [3 ]
Smith, Craig R. [3 ]
Kueh, Shaw Hua [1 ]
Ohana, Mickael [1 ]
Grover, Romi [1 ]
Naoum, Christopher [1 ]
Crowley, Aaron [9 ]
Jaber, Wael A. [10 ]
Alu, Maria C. [3 ]
Parvataneni, Rupa [9 ]
Mack, Michael [11 ]
Webb, John G. [1 ]
Leon, Martin B. [3 ]
Leipsic, Jonathon A. [1 ]
机构
[1] St Pauls Hosp, Vancouver, BC, Canada
[2] Univ Laval, Quebec City, PQ, Canada
[3] Columbia Univ, Med Ctr, New York, NY USA
[4] Univ Washington, Seattle, WA 98195 USA
[5] Duke Univ, Med Ctr, Duke Clin Res Inst, Durham, NC USA
[6] Georgetown Univ, Sch Med, Medstar Hlth Res Inst, Washington, DC USA
[7] Emory Univ, Sch Med, Atlanta, GA USA
[8] NYU Langone Med Ctr, New York, NY USA
[9] Cardiovasc Res Fdn, New York, NY USA
[10] Cleveland Clin, Cleveland, OH 44106 USA
[11] Baylor Scott & White Hlth, Plano, TX USA
关键词
VENTRICULAR OUTFLOW TRACT; LONG-TERM SURVIVAL; ECHOCARDIOGRAPHIC-ASSESSMENT; RISK PATIENTS; STENOSIS; IMPACT; AREA; RECOMMENDATIONS; DOPPLER; SURGERY;
D O I
10.1016/j.jcin.2017.05.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to determine if indexed effective orifice area (EOAi), using left ventricular outflow tract measured from computed tomography (EOAi(CT)), reclassified prosthesis-patient mismatch (PPM) compared with conventional echocardiogram-defined measurements (EOAi(TTE)). BACKGROUND PPM does not predict mortality following transcatheter aortic valve replacement (TAVR). However, it is unknown if the EOAi(CT) of the left ventricular outflow tract improves risk stratification. METHODS A total of 765 TAVR patients from the PARTNER II (Placement of Aortic Transcatheter Valves II) trial S3i cohort were evaluated. EOAi was calculated using the continuity equation, and the left ventricular outflow tract area was derived from baseline computed tomography. Traditional echocardiographic categories defined PPM: absent (> 0.85 cm(2)/m(2)), moderate (>= 0.65 and <= 0.85 cm(2)/m(2)), or severe (<= 0.65 cm(2)/m(2)). Correlation of EOAi(CT) and EOAi(TTE) to 1-year outcomes was performed. RESULTS The incidence of PPM was 24% with EOA(CT) compared with 45% with EOAi(TTE). Only 6% of PPM was graded severe by EOAi(CT) compared with 9% by EOAi(TTE). EOAi(TTE), but not EOAi(CT), defined PPM showed association with reduced left ventricular mass regression (p = 0.03 vs. p = 0.52). There was no association between PPM and death or rehospitalization at 1 year with either modality. EOA(CT) was associated with minor stroke at 1 year (log-rank p = 0.04), and EOAi(TTE) with stroke/transient ischemic attack (log-rank p = 0.030). Furthermore, when subjects with mild or greater paravalvular regurgitation were excluded, the presence of PPM did not show association with any outcome. CONCLUSIONS EOAi(CT) downgrades frequency and severity of PPM in patients after TAVR, and was not associated with mortality 1 year after TAVR. EOAi(TTE), but not EOAi(CT), was associated with less left ventricular mass regression. (C) 2017 by the American College of Cardiology Foundation.
引用
收藏
页码:1578 / 1587
页数:10
相关论文
共 24 条
[1]   Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical Practice [J].
Baumgartner, Helmut ;
Hung, Judy ;
Bermejo, Javier ;
Chambers, John B. ;
Evangelista, Arturo ;
Griffin, Brian P. ;
Iung, Bernard ;
Otto, Catherine M. ;
Pellikka, Patricia A. ;
Quinones, Miguel .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) :1-23
[2]   Aortic Valve Area Calculation in Aortic Stenosis by CT and Doppler Echocardiography [J].
Clavel, Marie-Annick ;
Malouf, Joseph ;
Messika-Zeitoun, David ;
Araoz, Phillip A. ;
Michelena, Hector I. ;
Enriquez-Sarano, Maurice .
JACC-CARDIOVASCULAR IMAGING, 2015, 8 (03) :248-257
[3]   Is patient-prosthesis mismatch a predictor of survival or a surrogate marker of co-morbidities in cardiac surgery? [J].
Dayan, Victor ;
Soca, Gerardo ;
Stanham, Roberto ;
Lorenzo, Alvaro ;
Ferreiro, Alejandro .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 190 :389-392
[4]   Effect of the ellipsoid shape of the left ventricular outflow tract on the echocardiographic assessment of aortic valve area in aortic stenosis [J].
De Vecchi, Clement ;
Caudron, Jerome ;
Dubourg, Benjamin ;
Pirot, Nathalie ;
Lefebvre, Valentin ;
Bauer, Fabrice ;
Eltchaninoff, Helene ;
Dacher, Jean-Nicolas .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (01) :52-57
[5]   Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT [J].
Doddamani, Sanjay ;
Grushko, Michael J. ;
Makaryus, Amgad N. ;
Jain, Vineet R. ;
Bello, Ricardo ;
Friedman, Mark A. ;
Ostfeld, Robert J. ;
Malhotra, Divya ;
Boxt, Lawrence M. ;
Haramati, Linda ;
Spevack, Daniel M. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (02) :175-181
[6]   Implementation of Echocardiography Core Laboratory Best Practices: A Case Study of the PARTNER I Trial [J].
Douglas, Pamela S. ;
Waugh, Robert A. ;
Bloomfield, Gerald ;
Dunn, Gary ;
Davis, LaGia ;
Hahn, Rebecca T. ;
Pibarot, Philippe ;
Stewart, William J. ;
Weissman, Neil J. ;
Hueter, Irene ;
Siegel, Robert ;
Lerakis, Stamatios ;
Miller, D. Craig ;
Smith, Craig R. ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (04) :348-+
[7]  
DUBOIS D, 1989, NUTRITION, V5, P303
[8]   Three-Dimensional Imaging of the Left Ventricular Outflow Tract: Impact on Aortic Valve Area Estimation by the Continuity Equation [J].
Gaspar, Tamar ;
Adawi, Salim ;
Sachner, Robert ;
Asmer, Ihab ;
Ganaeem, Majdi ;
Rubinshtein, Ronen ;
Shiran, Avinoam .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (07) :749-757
[9]   The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years [J].
Head, Stuart J. ;
Mokhles, Mostafa M. ;
Osnabrugge, Ruben L. J. ;
Pibarot, Philippe ;
Mack, Michael J. ;
Takkenberg, Johanna J. M. ;
Bogers, Ad J. J. C. ;
Kappetein, Arie Pieter .
EUROPEAN HEART JOURNAL, 2012, 33 (12) :1518-1529
[10]   Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: A prospective observational study [J].
Hong, Soonchang ;
Yi, Gijong ;
Youn, Young-Nam ;
Lee, Sak ;
Yoo, Kyung-Jong ;
Chang, Byung-Chul .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (05) :1098-1104