The wearable cardioverter defibrillator as a bridge to implantable defibrillator post myocardial infarction: what do we know?

被引:0
作者
Barsheshet, Alon [1 ,2 ]
Vamvouris, Theodora [1 ]
Goldenberg, Ilan [2 ,3 ]
机构
[1] Rabin Med Ctr, Dept Cardiol, Petah Tiqwa, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Sheba Med Ctr, Dept Cardiol, Leviev Heart Ctr, IL-52621 Tel Hashomer, Israel
关键词
Wearable cardioverter defibrillator; myocardial infarction; ventricular tachycardia; implantable cardioverter defibrillator; heart failure; LEFT-VENTRICULAR DYSFUNCTION; HIGH-RISK; SUDDEN-DEATH; THERAPY; REVASCULARIZATION; EXPERIENCE;
D O I
10.1080/17434440.2016.1200969
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Ventricular tachyarrhythmias (ventricular tachycardia and ventricular fibrillation) can lead to aborted cardiac arrest or sudden cardiac death in patients with poor left ventricular function early after acute myocardial infarction (AMI). Although it has been shown that the implantable cardioverter defibrillator (ICD) can treat ventricular tachyarrhythmias and save lives in patients with ischemic cardiomyopathy, it's use during the early phase post AMI has not been shown to reduce mortality. Current device guidelines require a waiting period of 40 days post AMI and 3 months post revascularization. Thus, there is a time gap where high-risk patients may not be protected.Areas covered: This review summarizes the characteristics of the wearable cardioverter-defibrillator (WCD) and its role in bridging the gap between an AMI and time of ICD eligibility. In addition, we focus on the efficacy of the WCD in treating ventricular tachyarrhythmias events, compliance and safety of the WCD use.Expert commentary: The WCD use during the early post AMI period can add crucial information to the process of risk stratification and decision-making whether an individual needs an implantation of an ICD or not. The WCD can serve as a safe and effective bridge during the interval preceding ICD placement.
引用
收藏
页码:627 / 632
页数:6
相关论文
共 21 条
  • [1] Sudden Death After Myocardial Infarction
    Adabag, A. Selcuk
    Therneau, Terry M.
    Gersh, Bernard J.
    Weston, Susan A.
    Roger, Veronique L.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 300 (17): : 2022 - 2029
  • [2] [Anonymous], 2015, J INNOV CARD RHYTHM, DOI DOI 10.19102/ICRM.2015.060302
  • [3] Clinical efficacy of the wearable cardioverter-defibrillator in acutely terminating episodes of ventricular fibrillation
    Auricchio, A
    Klein, H
    Geller, CJ
    Reek, S
    Heilamn, MS
    Szymkiewicz, SJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (10) : 1253 - +
  • [4] Aggregate National Experience With the Wearable Cardioverter-Defibrillator Event Rates, Compliance, and Survival
    Chung, Mina K.
    Szymkiewicz, Steven J.
    Shao, Mingyuan
    Zishiri, Edwin
    Niebauer, Mark J.
    Lindsay, Bruce D.
    Tchou, Patrick J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (03) : 194 - 203
  • [5] Evaluation of the effectiveness of a wearable cardioverter defibrillator detection algorithm
    Dillon, Katie A.
    Szymkiewicz, Steven J.
    Kaib, Thomas E.
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2010, 43 (01) : 63 - 67
  • [6] Wearable Cardioverter-Defibrillator Use in Patients Perceived to Be at High Risk Early Post-Myocardial Infarction
    Epstein, Andrew E.
    Abraham, William T.
    Bianco, Nicole R.
    Kern, Karl B.
    Mirro, Michael
    Rao, Sunil V.
    Rhee, Edward K.
    Solomon, Scott D.
    Szymkiewicz, Steven J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (21) : 2000 - 2007
  • [7] Noninvasive risk assessment early after a myocardial infarction
    Exner, Derek V.
    Kavanagh, Katherine M.
    Slawnych, Michael P.
    Mitchell, L. Brent
    Ramadan, Darlene
    Aggarwal, Sandeep G.
    Noullett, Catherine
    Van Schaik, Allie
    Mitchell, Ryan T.
    Shibata, Mariko A.
    Gulamhussein, Sajad
    McMeekin, James
    Tymchak, Wayne
    Schnell, Gregory
    Gillis, Anne M.
    Sheldon, Robert S.
    Fick, Gordon H.
    Duff, Henry J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (24) : 2275 - 2284
  • [8] Use of a wearable defibrillator in terminating tachyarrhythmias in patients at high risk for sudden death: Results of WEARIT/BIROAD
    Feldman, AM
    Klein, H
    Tchou, P
    Murali, S
    Hall, WJ
    Mancini, D
    Boehmer, J
    Harvey, M
    Hellman, MS
    Szymkiewicz, SJ
    Moss, AJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (01): : 4 - 9
  • [9] Implantable Cardioverter-Defibrillator Therapy After Acute Myocardial Infarction The Results Are Not Shocking
    Goldberger, Jeffrey J.
    Passman, Rod
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (22) : 2001 - 2005
  • [10] Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction
    Hohnloser, SH
    Kuck, KH
    Dorian, P
    Roberts, RS
    Hampton, JR
    Hatala, R
    Fain, E
    Gent, M
    Connolly, SJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (24) : 2481 - 2488