Noise in the intensive care unit and its influence on sleep quality: a multicenter observational study in Dutch intensive care units

被引:81
作者
Simons, Koen S. [1 ,9 ]
Verweij, Eva [1 ]
Lemmens, Paul M. C. [2 ]
Jelfs, Sam [2 ]
Park, Munhum [3 ]
Spronk, Peter E. [4 ]
Sonneveld, Johannes P. C. [5 ]
Feijen, Hilde-Marieken [6 ]
van der Steen, Marijke S. [7 ]
Kohlrausch, Armin G. [8 ]
van den Boogaard, Mark [9 ]
de Jager, Cornelis P. C. [1 ]
机构
[1] Jeroen Bosch Ziekenhuis, Dept Intens Care, Henri Dunantstr 1, NL-5223 GZ sHertogenbosch, Netherlands
[2] Philips Res, Eindhoven, Netherlands
[3] King Mongkuts Inst Technol Ladkrabang, Inst Mus Sci & Engn, Bangkok, Thailand
[4] Gelre Ziekenhuizen, Dept Intens Care, Apeldoorn, Netherlands
[5] Isala Klin, Dept Intens Care, Zwolle, Netherlands
[6] Onze Lieve Vrouw Hosp, Dept Intens Care, Amsterdam, Netherlands
[7] Ziekenhuis Gelderse Vallei, Dept Intens Care, Ede, Netherlands
[8] Tech Univ Eindhoven, Human Technol Interact Grp, Eindhoven, Netherlands
[9] Radboud Univ Nijmegen, Dept Intens Care Res, Med Ctr, Nijmegen, Netherlands
来源
CRITICAL CARE | 2018年 / 22卷
关键词
Noise; Sleep quality; Intensive care unit; Critical illness; RCSQ; MECHANICALLY VENTILATED PATIENTS; ENVIRONMENTAL NOISE; DISRUPTION; PATIENT; MODELS;
D O I
10.1186/s13054-018-2182-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: High noise levels in the intensive care unit (ICU) are a well-known problem. Little is known about the effect of noise on sleep quality in ICU patients. The study aim is to determine the effect of noise on subjective sleep quality. Methods: This was a multicenter observational study in six Dutch ICUs. Noise recording equipment was installed in 2-4 rooms per ICU. Adult patients were eligible for the study 48 h after ICU admission and were followed up to maximum of five nights in the ICU. Exclusion criteria were presence of delirium and/or inability to be assessed for sleep quality. Sleep was evaluated using the Richards Campbell Sleep Questionnaire (range 0-100 mm). Noise recordings were used for analysis of various auditory parameters, including the number and duration of restorative periods. Hierarchical mixed model regression analysis was used to determine associations between noise and sleep. Results: In total, 64 patients (68% male), mean age 63.9 (+/- 11.7) years and mean Acute Physiology And Chronic Health Evaluation (APACHE) II score 21.1 (+/- 7.1) were included. Average sleep quality score was 56 +/- 24 mm. The mean of the 24-h average sound pressure levels (L-Aeq, (24h)) was 54.0 dBA (+/- 2.4). Mixed-effects regression analyses showed that background noise (beta = -0.51, p < 0.05) had a negative impact on sleep quality, whereas number of restorative periods (beta = 0.53, p < 0.01) and female sex (beta = 1.25, p < 0.01) were weakly but significantly correlated with sleep. Conclusions: Noise levels are negatively associated and restorative periods and female gender are positively associated with subjective sleep quality in ICU patients.
引用
收藏
页数:8
相关论文
共 30 条
[1]   Environmental noise as a cause of sleep disruption in an intermediate respiratory care unit [J].
Aaron, JN ;
Carlisle, CC ;
Carskadon, MA ;
Meyer, TJ ;
Hill, NS ;
Millman, RP .
SLEEP, 1996, 19 (09) :707-710
[2]   Auditory and non-auditory effects of noise on health [J].
Basner, Mathias ;
Babisch, Wolfgang ;
Davis, Adrian ;
Brink, Mark ;
Clark, Charlotte ;
Janssen, Sabine ;
Stansfeld, Stephen .
LANCET, 2014, 383 (9925) :1325-1332
[3]  
Berglund B., 1999, World health organization: Guidelines for community noise
[4]   Sleep quality in mechanically ventilated patients: Comparison of three ventilatory modes [J].
Cabello, Belen ;
Thille, Arnaud W. ;
Drouot, Xavier ;
Galia, Fabrice ;
Mancebo, Jordi ;
d'Ortho, Marie-Pia ;
Brochard, Laurent .
CRITICAL CARE MEDICINE, 2008, 36 (06) :1749-1755
[5]  
Chalupper J, 2002, ACTA ACUST UNITED AC, V88, P378
[6]  
Cowan JamesP., 1994, Handbook of Environmental Acoustics
[7]   Excessive noise in intensive care units Bad for staff and very bad for patients [J].
Darbyshire, Julie L. .
BMJ-BRITISH MEDICAL JOURNAL, 2016, 353
[8]   An investigation of sound levels on intensive care units with reference to the WHO guidelines [J].
Darbyshire, Julie L. ;
Young, Duncan .
CRITICAL CARE, 2013, 17 (05)
[9]   Characterisation of sleep in intensive care using 24-hour polysomnography: an observational study [J].
Elliott, Rosalind ;
McKinley, Sharon ;
Cistulli, Peter ;
Fien, Mary .
CRITICAL CARE, 2013, 17 (02)
[10]   Exploring Gender Difference in Sleep Quality of Young Adults: Findings from a Large Population Study [J].
Fatima, Yaqoot ;
Doi, Suhail A. R. ;
Najman, Jake M. ;
Al Mamun, Abdullah .
CLINICAL MEDICINE & RESEARCH, 2016, 14 (3-4) :138-144