Prediction method of the long-term thermal performance of Vacuum Insulation Panels installed in building thermal insulation applications

被引:27
|
作者
Batard, A. [1 ,2 ]
Duforestel, T. [1 ]
Flandin, L. [2 ]
Yrieix, B. [3 ]
机构
[1] EDF R&D, ENERBAT, EDF Lab Renardires, F-77818 Moret Sur Loing, France
[2] Univ Savoie, LMOPS, LEPMI, Campus Savoie Technol Hlios, F-73376 Le Bourget Du Lac, France
[3] EDF R&D, MMC, EDF Lab Renardires, F-77818 Moret Sur Loing, France
关键词
Vacuum insulation panels; Core material behaviour; Building insulation; Modelling; Real solicitations; RADIATIVE-TRANSFER EQUATIONS; SERVICE LIFE; SILICA CORE; APPROXIMATION; DIFFUSION;
D O I
10.1016/j.enbuild.2018.08.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Vacuum Insulation Panels (VIPs) are super-insulating products that can be used for different applications. When they are used for building thermal insulation, they have to maintain a very high thermal performance in long-term. The initial thermal conductivity of VIPs is around 4 mW.m(-1).K-1. This very low value will increase in time, depending on the nanoporous property of the core material and on the barrier envelope efficiency which prevents the increase of moisture and internal pressure. To estimate the long-term thermal performance of VIPs, modelling is required. Simulations have shown the very great importance of the core material characteristics, and the external temperature and humidity conditions. That is why it is necessary to study the VIPs behaviour with realistic solicitations in service life for each VIP configuration. This paper proposes a methodology for determining the long-term thermal performance of VIPs when they are installed in envelope components for various building thermal insulation applications. All the methodology including the climate conditions, the building modelling and the insulation systems, is described. Severity criteria and performance indicators are proposed in order to estimate the thermal efficiency of VIPs in various applications and climates. (C) 2018 Published by Elsevier B.V.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] Prediction of thermal performance of vacuum insulation panels (VIPs) with micro-fiber core materials
    Mao, Shang
    Kan, Anakang
    Huang, Zipei
    Zhu, Wenbing
    MATERIALS TODAY COMMUNICATIONS, 2020, 22
  • [22] EFFECT OF SURFACE GAS BARRIER OF PLASTIC INSULATION FOAMS ON LONG-TERM THERMAL INSULATION PERFORMANCE
    Nagasawa Y.
    Kondo Y.
    AIJ Journal of Technology and Design, 2023, 29 (71) : 239 - 244
  • [23] Comparison of thermal insulation performance of vacuum insulation panels with EPS protection layers measured with different methods
    Lakatos, Akos
    Kovacs, Zsolt
    ENERGY AND BUILDINGS, 2021, 236
  • [24] Thermal Properties of Vacuum Insulation Panels with Glass Fiber
    Wu, Wangping
    Chen, Zhaofeng
    Zhou, Jieming
    Cheng, Xueyu
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 3753 - +
  • [25] Thermal accommodation in nanoporous silica for vacuum insulation panels
    Sonnick S.
    Meier M.
    Ünsal-Peter G.
    Erlbeck L.
    Nirschl H.
    Rädle M.
    International Journal of Thermofluids, 2020, 1-2
  • [26] Prediction and Optimization of Thermal Conductivity of Vacuum Insulation Panels with Aerogel Composite Cores
    Liang, Yuying
    Wu, Huijun
    Huang, Gongsheng
    Yang, Jianming
    Ding, Yunfei
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2855 - 2862
  • [27] Encapsulated vacuum insulation panels: theoretical thermal optimization
    Tenpierik, Martin J.
    Cauberg, Johannes J. M.
    BUILDING RESEARCH AND INFORMATION, 2010, 38 (06): : 660 - 669
  • [28] Thermal performance evaluation on vacuum insulation panels in composite building envelope under large temperature variations
    Kan, Ankang
    Hu, Jin
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2017, 12 (01) : 51 - 53
  • [30] Investigations into Ageing and Thermal Bridging in Vacuum Insulation Panels (VIP) for Construction Applications
    Sprengard, Christoph
    Spitzner, Martin H.
    BAUPHYSIK, 2011, 33 (04) : 234 - 242