New method of dynamic color doppler signal quantification in metastatic lymph nodes compared to direct polarographic measurements of tissue oxygenation

被引:29
作者
Scholbach, T
Scholbach, J
Krombach, GA
Gagel, B
Maneschi, P
Di Martino, E
机构
[1] Stadt Klinikum St Georg, Kinderklin, D-04229 Leipzig, Germany
[2] Ecole Normale Super, Dept Math, F-75231 Paris, France
[3] Univ Aachen, Dept Radiol, D-5100 Aachen, Germany
[4] Univ Aachen, Dept Radiotherapy, D-5100 Aachen, Germany
[5] Univ Aachen, Dept Otorhinolaryngol & Plast Head & Neck Surg, D-5100 Aachen, Germany
关键词
lymph node perfusion; signal quantification software; color Doppler sonography; tumor perfusion; tumor oxygenation; neck metastases;
D O I
10.1002/ijc.20827
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Tumor growth depends on sufficient blood and oxygen supply. Hypoxia stimulates neovascularization and is a known cause for radio- and chemoresistance. The objective of this study was to investigate the use of a novel ultrasound technique for the dynamic assessment of vascularization and oxygenation in metastatic lymph nodes. Twenty-four patients (age 44-78 years) with cervical lymph node metastases of squamous cell head and neck cancer were investigated by color duplex sonography and 17 (age 46-78 years) were investigated additionally with polarography. Sonography was performed after contrast enhancer infusion under defined conditions. Intranodal perfusion data (color hue, colored area) were measured automatically by a novel software technique. This allows an evaluation of blood flow dynamics by calculating perfusion intensity-velocity, perfused area, as well as the novel parameters tissue resistance index (TRI) and tissue pulsatility index (TPI)-for each point of a complete heart cycle. Tumor tissue pO(2) was measured by means of polarographic needle electrodes placed intranodally. The sonographic and polarographic data were correlated using Pearson's test. Sonography demonstrated a statistically significant inverse correlation between hypoxia and perfusion and significant TPI and TRI changes with different N-stages. The percentage of nodal fraction with less than 10 mmHg oxygen saturation was significantly inversely correlated with lymph node perfusion (r = - 0.551; p = 0.021). Nodes with a perfusion of less than 0.05 cm/sec flow velocity showed significantly larger hypoxic areas (p = 0.006). Significant differences of TPI and TRI existed between nodes in stage N-1 and N-2/N-3 (P = 0.028 and 0.048, respectively). This new method of dynamic signal quantification allows a noninvasive and quantitative assessment of tumor and metastatic lymph node perfusion by means of commonly available ultrasound equipment. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 55 条
[21]  
FOLKMAN J, 1999, ANGIOGENESIS RES LAB
[22]  
Fu X, 1998, Zhongguo Yi Xue Ke Xue Yuan Xue Bao, V20, P454
[23]  
Gee MS, 2001, CANCER RES, V61, P2974
[24]  
Giles FJ, 2001, ONCOLOGIST, V6, P32
[25]  
Gillies Robert J., 1999, Neoplasia (New York), V1, P197, DOI 10.1038/sj.neo.7900037
[26]   Intratumoral blood flow characteristics and prognostic factors in patients with endometrial carcinoma [J].
Greco P. ;
Vimercati A. ;
Cormio G. ;
Loverro G. ;
Selvaggi L. .
Archives of Gynecology and Obstetrics, 2002, 267 (1) :1-3
[27]  
Höckel M, 1999, CANCER RES, V59, P4525
[28]   TUMOR BLOOD-FLOW - THE PRINCIPAL MODULATOR OF OXIDATIVE AND GLYCOLYTIC METABOLISM, AND OF THE METABOLIC MICROMILIEU OF HUMAN-TUMOR XENOGRAFTS INVIVO [J].
KALLINOWSKI, F ;
SCHLENGER, KH ;
KLOES, M ;
STOHRER, M ;
VAUPEL, P .
INTERNATIONAL JOURNAL OF CANCER, 1989, 44 (02) :266-272
[29]  
KALLINOWSKI F, 1989, CANCER RES, V49, P3759
[30]  
Koukourakis MI, 2001, ANTICANCER RES, V21, P4285