摘要
The present work demonstrates that simultaneous determination of dopamine (DA), piroxicam (PRX), and cefixime (CEF) can be performed on the composite of multiwalled carbon nanotubes (MWCNTs), nickel hydroxide nanoparticles (NHNPs), and MCM-41 modified glassy carbon electrode (MWCNTs-NHNPs-MCM-41/GCE). The effect of the composition of MWCNTs, NHNPs, and MCM-41 for the modification of GCE was tested, and the mixture of 5 % NHNPs, 10 % MCM-41, and 85 % MWCNTs was chosen for the fabrication of the sensor. The MWCNTs-NHNPs-MCM-41 composite was characterized by Fourier transform infrared (FTIR), scanning electron microscopy (SEM), and energy-dispersive X-ray (EDX) analysis. Under optimum conditions, the application of differential pulse voltammetry method showed the linear relationship between oxidation peak currents, and the corresponding concentrations of DA, PRX, and CEF were 0.2-85, 0.1-70, and 0.1-200 mu M with detection limits of 0.07, 0.04, and 0.05 mu M, respectively. The proposed method was used in the determination of these compounds in human urine and blood serum samples with satisfactory results.
引用
收藏
页码:1731 / 1740
页数:10
相关论文
共 35 条
[1]   Electrochemical monitoring of piroxicam in different pharmaceutical forms with multi-walled carbon nanotubes paste electrode [J].
Abbaspour, Abdolkarim ;
Mirzajani, Roya .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (01) :41-48
[2]   Gold nanoparticles modified carbon paste electrode as an efficient electrochemical sensor for rapid and sensitive determination of cefixime in urine and pharmaceutical samples [J].
Afkhami, Abbas ;
Soltani-Felehgari, Farzaneh ;
Madrakian, Tayyebeh .
ELECTROCHIMICA ACTA, 2013, 103 :125-133
[3]   Nafion/Ni(OH)2 nanoparticles-carbon nanotube composite modified glassy carbon electrode as a sensor for simultaneous determination of dopamine and serotonin in the presence of ascorbic acid [J].
Babaei, Ali ;
Taheri, Ali Reza .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 :543-551
[4]   A Sensitive Simultaneous Determination of Epinephrine and Piroxicam Using a Glassy Carbon Electrode Modified with a Nickel Hydroxide Nanoparticles/Multiwalled Carbon Nanotubes Composite [J].
Babaei, Ali ;
Sohrabi, Masoud ;
Afrasiabi, Mohammad .
ELECTROANALYSIS, 2012, 24 (12) :2387-2394
[5]   Fluorimetric determination of some antibiotics in raw material and dosage forms through ternary complex formation with terbium (Tb3+) [J].
Bebawy, LI ;
El Kelani, K ;
Fattah, LA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (06) :1219-1225
[6]   Carbon nanotubule membranes for electrochemical energy storage and production [J].
Che, GL ;
Lakshmi, BB ;
Fisher, ER ;
Martin, CR .
NATURE, 1998, 393 (6683) :346-349
[7]   The substantia nigra of the human brain - II. Patterns of loss of dopamine-containing neurons in Parkinson's disease [J].
Damier, P ;
Hirsch, EC ;
Agid, Y ;
Graybiel, AM .
BRAIN, 1999, 122 :1437-1448
[8]   Multiwall carbon nanotubes decorated with NiFe2O4 magnetic nanoparticles, a new catalyst for voltammetric determination of cefixime [J].
Ensafi, Ali A. ;
Allafchian, Ali R. .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 102 :687-693
[9]   HPTLC determination of ceftriaxone, cefixime and cefotaxime in dosage forms [J].
Eric-Jovanovic, S ;
Agbaba, D ;
Zivanov-Stakic, D ;
Vladimirov, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) :893-898
[10]   Spectrofluorimetric determination of piroxicam in the presence and absence of β-cyclodextrin [J].
Escandar, GM .
ANALYST, 1999, 124 (04) :587-591