Comparing model-based adaptive LMS filters and a model-free hysteresis loop analysis method for structural health monitoring

被引:31
作者
Zhou, Cong [1 ]
Chase, J. Geoffrey [1 ]
Rodgers, Geoffrey W. [1 ]
Xu, Chao [2 ]
机构
[1] Univ Canterbury, Dept Mech Engn, Christchurch, New Zealand
[2] Northwestern Polytech Univ, Sch Astronaut, Xian, Peoples R China
关键词
Structural health monitoring; Hysteresis loop analysis; Adaptive filter; Damage identification; Model-based; Reinforced concrete experimental structure; REINFORCED-CONCRETE BUILDINGS; UNSCENTED KALMAN FILTER; PARAMETER-IDENTIFICATION; RANDOM VIBRATION; SYSTEM-IDENTIFICATION; STEEL BUILDINGS; SEISMIC DESIGN; DAMAGE; PERFORMANCE; LESSONS;
D O I
10.1016/j.ymssp.2016.07.030
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The model-free hysteresis loop analysis (HLA) method for structural health monitoring (SHM) has significant advantages over the traditional model-based SHM methods that require a suitable baseline model to represent the actual system response. This paper provides a unique validation against both an experimental reinforced concrete (RC) building and a calibrated numerical model to delineate the capability of the model-free HLA method and the adaptive least mean squares (LMS) model-based method in detecting, localizing and quantifying damage that may not be visible, observable in overall structural response. Results clearly show the model-free HLA method is capable of adapting to changes in how structures transfer load or demand across structural elements over time and multiple events of different size. However, the adaptive LMS model-based method presented an image of greater spread of lesser damage over time and story when the baseline model is not well defined. Finally, the two algorithms are tested over a simpler hysteretic behaviour typical steel structure to quantify the impact of model mismatch between the baseline model used for identification and the actual response. The overall results highlight the need for model-based methods to have an appropriate model that can capture the observed response, in order to yield accurate results, even in small events where the structure remains linear. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:384 / 398
页数:15
相关论文
共 49 条
[1]   Structural health assessment at a local level using minimum information [J].
Al-Hussein, Abdullah ;
Haldar, Achintya .
ENGINEERING STRUCTURES, 2015, 88 :100-110
[2]  
[Anonymous], 2013, COD SEISM DES BUILD
[3]  
Baber T.T., 1980, Stochastic Equivalent Linearization for Hysteretic, Degrading, Multistory Structures
[4]   RANDOM VIBRATION OF DEGRADING, PINCHING SYSTEMS [J].
BABER, TT ;
NOORI, MN .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1985, 111 (08) :1010-1026
[5]   MODELING GENERAL HYSTERESIS BEHAVIOR AND RANDOM VIBRATION APPLICATION [J].
BABER, TT ;
NOORI, MN .
JOURNAL OF VIBRATION ACOUSTICS STRESS AND RELIABILITY IN DESIGN-TRANSACTIONS OF THE ASME, 1986, 108 (04) :411-420
[6]   Estimating and testing linear models with multiple structural changes [J].
Bai, JS ;
Perron, P .
ECONOMETRICA, 1998, 66 (01) :47-78
[7]  
BOUC R., 1967, Forced Vibrations of Mechanical Systems with Hysteresis"
[8]   LMS-based structural health monitoring of a non-linear rocking structure [J].
Chase, JG ;
Spieth, HA ;
Blome, CF ;
Mander, JB .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2005, 34 (08) :909-930
[9]   A simple LMS-based approach to the structural health monitoring benchmark problem [J].
Chase, JG ;
Hwang, KL ;
Barroso, LR ;
Mander, JB .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2005, 34 (06) :575-594
[10]   DYNAMICS OF SOIL-BASE-ISOLATED-STRUCTURE SYSTEMS [J].
CONSTANTINOU, MC ;
KNEIFATI, MC .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1988, 114 (01) :211-221