Submillisievert Radiation Dose Coronary CT Angiography: Clinical Impact of the Knowledge-Based Iterative Model Reconstruction

被引:17
|
作者
Iyama, Yuji [1 ,2 ]
Nakaura, Takeshi [1 ,2 ]
Kidoh, Masafumi [2 ]
Oda, Seitaro [2 ]
Utsunomiya, Daisuke [2 ]
Sakaino, Naritsugu [3 ]
Tokuyasu, Shinichi [4 ]
Osakabe, Hirokazu [4 ]
Harada, Kazunori [5 ]
Yamashita, Yasuyuki [2 ]
机构
[1] Amakusa Med Ctr, Diagnost Radiol, Kameba 854-1, Kumamoto 8630046, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto, Japan
[3] Amakusa Med Ctr, Dept Cardiovasc Internal Med, Kumamoto, Japan
[4] Philips Elect Japan, Tokyo, Japan
[5] Amakusa Med Ctr, Dept Surg, Kumamoto, Japan
关键词
Computed tomography (CT); iterative reconstruction; radiation dose; CARDIAC COMPUTED-TOMOGRAPHY; FILTERED BACK-PROJECTION; IMAGE QUALITY; ABDOMINAL CT; REDUCTION; ALGORITHM; NOISE; MBIR;
D O I
10.1016/j.acra.2016.07.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The purpose of this study was to evaluate the noise and image quality of images reconstructed with a knowledge-based iterative model reconstruction (knowledge-based IMR) in ultra-low dose cardiac computed tomography (CT). Materials and Methods: We performed submillisievert radiation dose coronary CT angiography on 43 patients. We also performed a phantom study to evaluate the influence of object size with the automatic exposure control phantom. We reconstructed clinical and phantom studies with filtered back projection (FBP), hybrid iterative reconstruction (hybrid IR), and knowledge-based IMR. We measured effective dose of patients and compared CT number, image noise, and contrast noise ratio in ascending aorta of each reconstruction technique. We compared the relationship between image noise and body mass index for the clinical study, and object size for phantom study. Results: The mean effective dose was 0.98 +/- 0.25 mSv. The image noise of knowledge-based IMR images was significantly lower than those of FBP and hybrid IR images (knowledge-based IMR: 19.4 +/- 2.8; FBP: 126.7 +/- 35.0; hybrid IR: 48.8 +/- 12.8, respectively) (P < .01). The contrast noise ratio of knowledge based IMR images was significantly higher than those of FBP and hybrid IR images (knowledge based IMR: 29.1 +/- 5.4; FBP: 4.6 +/- 1.3; hybrid IR: 13.1 +/- 3.5, respectively) (P < .01). There were moderate correlations between image noise and body mass index in FBP (r = 0.57, P < .01) and hybrid IR techniques (r = 0.42, P < .01); however, these correlations were weak in knowledge-based IMR (r = 0.27, P < .01). Conclusion: Compared to FBP and hybrid IR, the knowledge-based IMR offers significant noise reduction and improvement in image quality in submillisievert radiation dose cardiac CT.
引用
收藏
页码:1393 / 1401
页数:9
相关论文
共 50 条
  • [21] A New Era in Computed Tomographic Dose Optimization: The Impact of Iterative Reconstruction on Image Quality and Radiation Dose
    Kordolaimi, Sofia D.
    Argentos, Stylianos
    Pantos, Ioannis
    Kelekis, Nikolaos L.
    Efstathopoulos, Efstathios P.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (06) : 924 - 931
  • [22] Coronary CT Angiography with Use of Iterative Reconstruction Algorithm in Coronary Stenting: A Systematic Review of Image Quality, Diagnostic Value and Radiation Dose
    Al Shammakhi, Ahmed
    Sun, Zhonghua
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (01) : 103 - 109
  • [23] CT Radiation Dose and Iterative Reconstruction Techniques
    Padole, Atul
    Khawaja, Ranish Deedar Ali
    Kalra, Mannudeep K.
    Singh, Sarabjeet
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (04) : W384 - W387
  • [24] Submillisievert CT using model-based iterative reconstruction with lung-specific setting: An initial phantom study
    Hata, Akinori
    Yanagawa, Masahiro
    Honda, Osamu
    Gyobu, Tomoko
    Ueda, Ken
    Tomiyama, Noriyuki
    EUROPEAN RADIOLOGY, 2016, 26 (12) : 4457 - 4464
  • [25] Ultralow-dose CT with knowledge-based iterative model reconstruction (IMR) in evaluation of pulmonary tuberculosis: comparison of radiation dose and image quality
    Yan, Chenggong
    Liang, Chunyi
    Xu, Jun
    Wu, Yuankui
    Xiong, Wei
    Zheng, Huan
    Xu, Yikai
    EUROPEAN RADIOLOGY, 2019, 29 (10) : 5358 - 5366
  • [26] Coronary CT angiography with low radiation dose
    Xu, Lei
    Zhang, Zhaoqi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 17 - 25
  • [27] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Sonja Gordic
    Lotus Desbiolles
    Martin Sedlmair
    Robert Manka
    André Plass
    Bernhard Schmidt
    Daniela B. Husarik
    Francesco Maisano
    Simon Wildermuth
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2016, 26 : 459 - 468
  • [28] Ultra Low Dose CT Pulmonary Angiography with Iterative Reconstruction
    Sauter, Andreas
    Koehler, Thomas
    Fingerle, Alexander A.
    Brendel, Bernhard
    Richter, Vivien
    Rasper, Michael
    Rummeny, Ernst J.
    Noel, Peter B.
    Muenzel, Daniela
    PLOS ONE, 2016, 11 (09):
  • [29] Iterative reconstruction for coronary CT angiography: finding its way
    Leipsic, Jonathon
    Heilbron, Brett G.
    Hague, Cameron
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (03): : 613 - 620
  • [30] Comparison of Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection for Detecting Hepatic Metastases on Submillisievert Low-Dose Computed Tomography
    Son, Jung Hee
    Kim, Seung Ho
    Yoon, Jung-Hee
    Lee, Yedaun
    Lim, Yun-Jung
    Kim, Seon-Jeong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (04) : 644 - 650