Submillisievert Radiation Dose Coronary CT Angiography: Clinical Impact of the Knowledge-Based Iterative Model Reconstruction

被引:17
作者
Iyama, Yuji [1 ,2 ]
Nakaura, Takeshi [1 ,2 ]
Kidoh, Masafumi [2 ]
Oda, Seitaro [2 ]
Utsunomiya, Daisuke [2 ]
Sakaino, Naritsugu [3 ]
Tokuyasu, Shinichi [4 ]
Osakabe, Hirokazu [4 ]
Harada, Kazunori [5 ]
Yamashita, Yasuyuki [2 ]
机构
[1] Amakusa Med Ctr, Diagnost Radiol, Kameba 854-1, Kumamoto 8630046, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto, Japan
[3] Amakusa Med Ctr, Dept Cardiovasc Internal Med, Kumamoto, Japan
[4] Philips Elect Japan, Tokyo, Japan
[5] Amakusa Med Ctr, Dept Surg, Kumamoto, Japan
关键词
Computed tomography (CT); iterative reconstruction; radiation dose; CARDIAC COMPUTED-TOMOGRAPHY; FILTERED BACK-PROJECTION; IMAGE QUALITY; ABDOMINAL CT; REDUCTION; ALGORITHM; NOISE; MBIR;
D O I
10.1016/j.acra.2016.07.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The purpose of this study was to evaluate the noise and image quality of images reconstructed with a knowledge-based iterative model reconstruction (knowledge-based IMR) in ultra-low dose cardiac computed tomography (CT). Materials and Methods: We performed submillisievert radiation dose coronary CT angiography on 43 patients. We also performed a phantom study to evaluate the influence of object size with the automatic exposure control phantom. We reconstructed clinical and phantom studies with filtered back projection (FBP), hybrid iterative reconstruction (hybrid IR), and knowledge-based IMR. We measured effective dose of patients and compared CT number, image noise, and contrast noise ratio in ascending aorta of each reconstruction technique. We compared the relationship between image noise and body mass index for the clinical study, and object size for phantom study. Results: The mean effective dose was 0.98 +/- 0.25 mSv. The image noise of knowledge-based IMR images was significantly lower than those of FBP and hybrid IR images (knowledge-based IMR: 19.4 +/- 2.8; FBP: 126.7 +/- 35.0; hybrid IR: 48.8 +/- 12.8, respectively) (P < .01). The contrast noise ratio of knowledge based IMR images was significantly higher than those of FBP and hybrid IR images (knowledge based IMR: 29.1 +/- 5.4; FBP: 4.6 +/- 1.3; hybrid IR: 13.1 +/- 3.5, respectively) (P < .01). There were moderate correlations between image noise and body mass index in FBP (r = 0.57, P < .01) and hybrid IR techniques (r = 0.42, P < .01); however, these correlations were weak in knowledge-based IMR (r = 0.27, P < .01). Conclusion: Compared to FBP and hybrid IR, the knowledge-based IMR offers significant noise reduction and improvement in image quality in submillisievert radiation dose cardiac CT.
引用
收藏
页码:1393 / 1401
页数:9
相关论文
共 35 条
[1]   Model-Based Iterative Reconstruction for Radial Fast Spin-Echo MRI [J].
Block, Kai Tobias ;
Uecker, Martin ;
Frahm, Jens .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) :1759-1769
[2]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[3]  
Brown KM, 2012, P SOC PHOTO-OPT INS, P8313
[4]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[5]   Assessment of a Model-Based, Iterative Reconstruction Algorithm (MBIR) Regarding Image Quality and Dose Reduction in Liver Computed Tomography [J].
Chang, Won ;
Lee, Jeong Min ;
Lee, Kyunghee ;
Yoon, Jeong Hee ;
Yu, Mi Hye ;
Han, Joon Koo ;
Choi, Byung Ihn .
INVESTIGATIVE RADIOLOGY, 2013, 48 (08) :598-606
[6]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[7]   Distance-driven projection and backprojection in three dimensions [J].
De Man, B ;
Basu, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2463-2475
[8]   Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study [J].
Deak, Zsuzsanna ;
Grimm, Jochen M. ;
Treitl, Marcus ;
Geyer, Lucas L. ;
Linsenmaier, Ulrich ;
Koerner, Markus ;
Reiser, Maximilian F. ;
Wirth, Stefan .
RADIOLOGY, 2013, 266 (01) :197-206
[9]   Image Quality in Reduced-Dose Coronary CT Angiography [J].
Gagarina, Nina V. ;
Irwan, Roy ;
Gordina, Galina ;
Fominykh, Ekaterina ;
Sijens, Paul E. .
ACADEMIC RADIOLOGY, 2011, 18 (08) :984-990
[10]   CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT [J].
Gervaise, Alban ;
Osemont, Benoit ;
Lecocq, Sophie ;
Noel, Alain ;
Micard, Emilien ;
Felblinger, Jacques ;
Blum, Alain .
EUROPEAN RADIOLOGY, 2012, 22 (02) :295-301