A direct method to measure the power of the central cornea after myopic laser in situ keratomileusis

被引:66
作者
Sónego-Krone, S
López-Moreno, G
Beaujon-Balbi, OV
Arce, CG
Schor, P
Campos, M
机构
[1] Univ Fed Sao Paulo, Paulista Sch Med, Dept Ophthalmol, Sao Paulo, Brazil
[2] Francisco Risquez Hosp, Luis Razetti Clin, Caracas, Venezuela
[3] Francisco Risquez Hosp, Metropolitan Ctr Ophthalmol, Caracas, Venezuela
关键词
D O I
10.1001/archopht.122.2.159
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To measure the corneal power after myopic laser in situ keratomileusis (LASIK). Methods: Six central areas in 6 corneal power maps were studied using the Orbscan II statistical analysis device in 26 eyes that under-went myopic LASIK. Refractive and corneal power changes were compared. Factors related to wrong corneal power measurement were evaluated. Main Outcome Measures: Cycloplegic refraction, refractive change at the corneal plane, and Orbscan II corneal power maps. Results: Preoperatively, only posterior-mean power (P much less than .001) and anterior-posterior power ratio (P much less than .001) varied according to the size of the analyzed area. Postoperatively, total-optical (P = .03), keratometric-mean (P = .04), total-mean (P < .001), anterior-mean (P = .03), and posterior-mean (P much less than .001) powers; and anterior-posterior power ratio (P much less than .001) varied according to the area. Postoperatively, the difference between keratometric-mean and total-mean powers became larger (P < .001), and the anterior-posterior power ratio was reduced (P much less than .001). A posterior-mean power change occurred (P = .04). Refractive change after myopic LASIK was best estimated by 2-mm total-mean power (mean +/- SD difference, 0.07 +/- 0.62 diopters [D]; P = .55) and 4-mm total-optical power (mean +/- SD difference, -0.08 +/- 0.53 D; P = 37). Conclusions: Total corneal power is more positive and refractive change is underestimated when deduced from the anterior surface radius and keratometric refractive index. The anterior-posterior power ratio is not a fixed value. The best area to estimate the refractive change depends on the method used to obtain the power in diopters. Refractive change tended to be underestimated in larger areas and higher preoperative myopia. Orbscan II total-mean and total-optical power maps accurately assess the corneal power after myopic LASIK independent of preoperative data or correcting factors, and should improve intraocular lens calculation.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 43 条
[1]   Intraocular lens power calculation after corneal refractive surgery: Double-K method [J].
Aramberri, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2063-2068
[2]  
Assouline M, 1997, J FR OPHTALMOL, V20, P411
[3]  
BAUSCH, 2002, ORBSCAN 2 ORBSCAN 2Z
[4]   Accuracy of Orbscan II slit-scanning elevation topography [J].
Cairns, G ;
McGhee, CNJ ;
Collins, MJ ;
Owens, H ;
Gamble, GD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12) :2181-2187
[5]  
CAMELLIN M, 2000, IOL CALCULATOR CAMEL
[6]  
CHAVES HV, 2000, TOPOGRAFIA CORNEA AT, P143
[7]   COMPARISON OF THE ACCURACY OF COMPUTERIZED VIDEOKERATOGRAPHY AND KERATOMETRY FOR USE IN INTRAOCULAR-LENS CALCULATIONS [J].
CUAYCONG, MJ ;
GAY, CA ;
EMERY, J ;
HAFT, EA ;
KOCH, DD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 :178-181
[8]   Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia - A standardized approach [J].
Feiz, V ;
Mannis, MJ ;
Garcia-Ferrer, F ;
Kandavel, G ;
Darlington, JK ;
Kim, E ;
Caspar, J ;
Wang, JL ;
Wang, W .
CORNEA, 2001, 20 (08) :792-797
[9]   Refractive error in cataract surgery after previous refractive surgery [J].
Gimbel, H ;
Sun, R ;
Kaye, GB .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (01) :142-144
[10]   Accuracy and predictability of intraocular lens power calculation after photorefractive keratectomy [J].
Gimbel, HV ;
Sun, R ;
Furlong, MT ;
van Westenbrugge, JA ;
Kassab, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08) :1147-1151