Comparison of virtual cystoscopy, multiplanar reformation, and source CT images with contrast material-filled bladder for detecting lesions

被引:32
作者
Kim, JK
Park, SY
Kim, HS
Kim, SH
Cho, KS
机构
[1] Univ Ulsan, Dept Radiol, Asan Med Ctr, Seoul 138736, South Korea
[2] Inje Univ, Dept Radiol, Sanggyepaik Hosp, Seoul 139707, South Korea
关键词
D O I
10.2214/ajr.185.3.01850689
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to compare the diagnostic accuracy of virtual cystoscopy, multiplanar reformation, and source CT images for lesion detection in the contrast material-filled bladder. SUBJECTS AND METHODS. Two observers independently evaluated 47 patients (28 men and 19 women; mean age SD, 59 16 years) with virtual cystoscopy, multiplanar reconstruction, and source CT images acquired with contrast material-filled bladder using an MDCT scanner (detector array, 4 x 1.25 mm; beam pitch, 0.75). Agreement between the two observers was evaluated for the three reconstruction methods using kappa statistics. Using the conventional cystoscopic findings as a reference, we compared the results of the three reconstruction techniques both by bladder site and by patient using the McNemar test. RESULTS. The interobserver agreement for the number of positive sites was excellent for virtual cystoscopy (kappa = 0.816), fair for multiplanar reconstruction (kappa = 0.461), and good for source CT images (kappa = 0.676). For both observers, the sensitivity for lesion detection by bladder site was significantly greater with virtual cystoscopy (observer 1, 95%; observer 2, 90%) than with multiplanar reconstruction (78% and 60%) and source CT (68% and 65%) images (p < 0.05), whereas the specificity by bladder site and the sensitivity and specificity by patient did not differ with the three methods (p > 0.05). For determining the presence or absence of lesion at each site, virtual cystoscopy was more accurate than multiplanar reconstruction and source CT images for both observers (p < 0.05). CONCLUSION. Virtual cystoscopy is more accurate than multiplanar reconstruction and source CT images for the detection of lesions in the bladder.
引用
收藏
页码:689 / 696
页数:8
相关论文
共 19 条
[1]   SPREADING SEPSIS BY CYSTOSCOPY [J].
BAVETTA, S ;
OLSHA, O ;
FENELY, J .
POSTGRADUATE MEDICAL JOURNAL, 1990, 66 (779) :734-735
[2]   Diagnostic potential of virtual cystoscopy of the bladder: MRI vs CT. Preliminary report [J].
Bernhardt, TM ;
Schmidl, H ;
Philipp, C ;
Allhoff, EP ;
Rapp-Bernhardt, U .
EUROPEAN RADIOLOGY, 2003, 13 (02) :305-312
[3]   Virtual cystoscopy of the bladder based on CT and MRI data [J].
Bernhardt, TM ;
Rapp-Bernhardt, U .
ABDOMINAL IMAGING, 2001, 26 (03) :325-332
[4]   URINARY-INFECTION FOLLOWING OUTPATIENT FLEXIBLE CYSTOSCOPY [J].
CLARK, KR ;
HIGGS, MJ .
BRITISH JOURNAL OF UROLOGY, 1990, 66 (05) :503-505
[5]   Virtual cystoscopy: Early clinical experience [J].
Fenlon, HM ;
Bell, TV ;
Ahari, HK ;
Hussain, S .
RADIOLOGY, 1997, 205 (01) :272-275
[6]   Tumor detection by virtual cystoscopy with color mapping of bladder wall thickness [J].
Fielding, JR ;
Hoyte, L ;
Okon, SA ;
Schreyer, A ;
Lee, J ;
Zou, KH ;
Warfield, S ;
Richie, JP ;
Loughlin, KR ;
O'Leary, MP ;
Doyle, CJ ;
Kikinis, R .
JOURNAL OF UROLOGY, 2002, 167 (02) :559-562
[7]   Colorectal polyp detection with CT colography: Two- versus three-dimensional techniques - Work in progress [J].
Hara, AK ;
Johnson, CD ;
Reed, JE ;
Ehman, RL ;
Ilstrup, DM .
RADIOLOGY, 1996, 200 (01) :49-54
[8]  
*INT EL COM, 1999, 60601244 INT EL COMM
[9]   Tumor detection in the bladder wall with a measurement of abnormal thickness in CT scans [J].
Jaume, S ;
Ferrant, M ;
Macq, B ;
Hoyte, L ;
Fielding, JR ;
Schreyer, A ;
Kikinis, R ;
Warfield, SK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (03) :383-390
[10]   CT urography and virtual endoscopy: promising imaging modalities for urinary tract evaluation [J].
Kim, JK ;
Cho, KS .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (903) :199-209