Respiratory motion in positron emission tomography/computed tomography: A review

被引:247
作者
Nehmeh, Sadek A. [1 ]
Erdi, Yusuf E. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
D O I
10.1053/j.semnuclmed.2008.01.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The development of positron emission tomography/computed tomography (PET/CT) scanners has allowed not only straightforward but also synergistic fusion of anatomical and functional information. Combined PET/CT imaging yields an increased sensitivity and specificity beyond that which either of the 2 modalities possesses separately and therefore provides improved diagnostic accuracy. Because attenuation correction in PET is performed with the use of CT images, with CT used in the localization of disease, accurate spatial registration of PET and CT image sets is required. Correcting for the spatial mismatch caused by respiratory motion represents a particular challenge for the requisite registration accuracy as a result of differences in temporal resolution between the 2 modalities. This review provides a brief summary of the materials, methods, and results involved in multiple investigations of the correction for respiratory motion in PET/CT imaging of the thorax, with the goal of improving image quality and quantitation. Although some schemes use respiratory-phase data selection to exclude motion artifacts, others have adopted sophisticated software techniques. The various image artifacts associated with breathing motion are also described.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 54 条
[1]   Intensity modulation with respiratory gating for radiotherapy of the pleural space [J].
Ahmed, Raef S. ;
Shen, Sui ;
Ove, Roger ;
Duan, Jun ;
Fiveash, John B. ;
Russo, Suzanne M. .
MEDICAL DOSIMETRY, 2007, 32 (01) :16-22
[2]  
Beyer T, 2004, J NUCL MED, V45, p25S
[3]   Positron emission tomography/computed tomography: Protocol issues and options [J].
Blodgett, TM ;
McCook, BM ;
Federle, MP .
SEMINARS IN NUCLEAR MEDICINE, 2006, 36 (02) :157-168
[4]   Positron emission tomography/computed tomography-imaging protocols, artifacts, and pitfalls [J].
Bockisch, A ;
Beyer, T ;
Antoch, G ;
Freudenberg, LS ;
Kühl, H ;
Debatin, JF ;
Müller, SP .
MOLECULAR IMAGING AND BIOLOGY, 2004, 6 (04) :188-199
[5]  
Boucher L, 2004, J NUCL MED, V45, P214
[6]  
Brink I, 2001, J NUCL MED, V42, P591
[7]   Integrating respiratory gating into a megavoltage cone-beam CT system [J].
Chang, Jenghwa ;
Sillanpaa, Jussi ;
Ling, Clifton C. ;
Seppi, Edward ;
Yorke, Ellen ;
Mageras, Gikas ;
Amols, Howard .
MEDICAL PHYSICS, 2006, 33 (07) :2354-2361
[8]   Relation of external surface to internal tumor motion studied with cine CT [J].
Chi, Pai-Chun Melinda ;
Balter, Peter ;
Luo, Dershan ;
Mohan, Radhe ;
Pan, Tinsu .
MEDICAL PHYSICS, 2006, 33 (09) :3116-3123
[9]   Lung motion correction on respiratory gated 3-D PET/CT images [J].
Dawood, M ;
Lang, N ;
Jiang, XY ;
Schäfers, KP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (04) :476-485
[10]   Linac-integrated 4D cone beam CT:: first experimental results [J].
Dietrich, Lars ;
Jetter, Siri ;
Tuecking, Thomas ;
Nill, Simeon ;
Oelfke, Uwe .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11) :2939-2952