Midwives' and Women's Perception on Moyo Fetal Heart Rate Monitor for Intrapartum Fetal Heart Rate Monitoring; A Cross-Sectional Study

被引:3
|
作者
Mdoe, Paschal [1 ]
Yeconia, Anita [1 ]
Buu, Fanuel [1 ]
Kusulla, Simeon [1 ]
Blacy, Ladislaus [1 ]
Guga, Godfrey [1 ]
Mduma, Estomih [1 ]
Kidanto, Hussein [1 ]
机构
[1] Haydom Lutheran Hosp, Dept Res, Haydom, Tanzania
关键词
Moyo; fetal heart rate; labor; midwives; women; NEONATAL-MORTALITY;
D O I
10.2147/MDER.S241741
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The annual global neonatal mortality stands at 2.5 million deaths, 1 million of them dying within the first day of life. An additional 2.6 million are stillborn globally, the majority of them due to intrapartum events. Optimal fetal heart rate (FHR) monitoring has the potential to timely detect fetuses at risk and, if coupled with timely obstetric responses may save more newborns. Moyo is a new Doppler with nine crystals capable of monitoring FHR both intermittently and continuously. Aim: To assess women's and midwives' opinions on the use of Moyo for intrapartum FHR monitoring. Methods: We conducted a cross-sectional study using a structured questionnaire to assess women's and midwives' perception. Women who gave birth at the hospital who used Moyo were interviewed using a questionnaire immediately before discharge from the hospital. Twenty-eight midwives who have been using Moyo for more than 6 months were also interviewed using a structured questionnaire. Data were analyzed using excel and result presented in figures. Results: In total 113 postpartum women who were monitored using Moyo were interviewed before discharge. Out of these, 46 (40.7%) were first-time mothers and the rest were multipara. In total, 95 women (84.1%) used Moyo and other devices for FHR monitoring, 81 (72%) said Moyo was better than Fetoscopes and handheld Doppler, two-third 75 (66.4%) felt that Moyo was comfortable and 93 (82.3%) would like Moyo to be used on them in the future. Out of 28 midwives, 11 (39.3%) used Moyo continuous only, 3 (10.7%) used Moyo intermittently only and 14 (50.0%) used both intermittent and continuous. Thirteen (46.4%) midwives prefer to use Moyo both intermittent and continuous. Sixteen (55.6%) said Moyo was effective, 21 (75%) felt comfortable to use Moyo, and 13 (46.4%) said Moyo was easy to use. Conclusion: The majority of midwives and women who used Moyo felt that Moyo was comfortable for intrapartum FHR monitoring. Moyo can be used both intermittently and continuously depending on the user's preferences.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [41] Timing intrapartum management based on the evolution and duration of fetal heart rate patterns
    Vintzileos, Anthony M.
    Smulian, John C.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (25) : 7936 - 7941
  • [42] Intrapartum fetal heart rate patterns of trisomy 21 fetuses: A case-control study
    Koren, Inbal
    Michaelson-Cohen, Rachel
    Chen, Daniela
    Michaeli, Jennia
    Schimmel, Michael
    Tsafrir, Avi
    Shen, Ori
    EARLY HUMAN DEVELOPMENT, 2016, 92 : 25 - 28
  • [43] Wireless, remote solution for home fetal and maternal heart rate monitoring
    Mhajna, Muhammad
    Schwartz, Nadav
    Levit-Rosen, Lorinne
    Warsof, Steven
    Lipschuetz, Michal
    Jakobs, Martin
    Rychik, Jack
    Sohn, Christof
    Yagel, Simcha
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2020, 2 (02)
  • [44] The clinical significance of electronic fetal heart rate monitoring in twins
    Dera-Szymanowska, Anna
    Polska, Martyna
    Markwitz, Wieslaw
    Moczko, Jerzy
    Horst, Nikodem
    Szymanowski, Krzysztof
    GINEKOLOGIA POLSKA, 2023, 94 (10) : 839 - 844
  • [45] Fetal scalp stimulation (FSS) versus fetal blood sampling (FBS) for women with abnormal fetal heart rate monitoring in labor: a prospective cohort study
    Mahmood, Uzma Tahir
    O'Gorman, Catherine
    Marchocki, Zibi
    O'Brien, Yvonne
    Murphy, Deirdre J.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2018, 31 (13) : 1742 - 1747
  • [46] In Search of Accurate Fetal Heart Rate Monitoring Mobile Applications
    Soffer, Marti D.
    Chen, Katherine T.
    TELEMEDICINE AND E-HEALTH, 2019, 25 (09) : 870 - 877
  • [47] Intrapartum fetal heart rate patterns in infants (≥34 weeks) with poor neurological outcome
    Kodama, Yuki
    Sarrieshima, Hiroshi
    Ikeda, Tomoaki
    Ikenoue, Tsuyomu
    EARLY HUMAN DEVELOPMENT, 2009, 85 (04) : 235 - 238
  • [48] Intrapartum management of category II fetal heart rate tracings: towards standardization of care
    Clark, Steven L.
    Nageotte, Michael P.
    Garite, Thomas J.
    Freeman, Roger K.
    Miller, David A.
    Simpson, Kathleen R.
    Belfort, Michael A.
    Dildy, Gary A.
    Parer, Julian T.
    Berkowitz, Richard L.
    D'Alton, Mary
    Rouse, Dwight J.
    Gilstrap, Larry C.
    Vintzileos, Anthony M.
    van Dorsten, J. Peter
    Boehm, Frank H.
    Miller, Lisa A.
    Hankins, Gary D. V.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2013, 209 (02) : 89 - 97
  • [49] Analysis of Intrapartum Fetal Heart Rate According to Umbilical Arterial pH and Age of Mother
    Gayraud, N. T. E.
    Argiri, M.
    Manis, G.
    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016, 2016, 57 : 1210 - 1215
  • [50] Computerised analysis of intrapartum fetal heart rate patterns and adverse outcomes in the INFANT trial
    Steer, P. J.
    Kovar, I
    McKenzie, C.
    Griffin, M.
    Linsell, L.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2019, 126 (11) : 1354 - 1361