Conventional instruments are more accurate for measuring the depth of the tibial cut than computer-assisted surgery in total knee arthroplasty: a prospective study

被引:14
作者
Klasan, Antonio [1 ]
Putnis, Sven Edward [1 ]
Grasso, Samuel [1 ]
Neri, Thomas [1 ]
Coolican, Myles Raphael [1 ]
机构
[1] Sydney Orthopaed Res Inst, 445 Victoria Ave, Chatswood, NSW 2067, Australia
关键词
Knee; Arthroplasty; Tibial component; Bone cut; Navigation; PATIENT-SPECIFIC INSTRUMENTATION; NAVIGATION SYSTEM; CUTTING ERRORS; REPLACEMENT; ALIGNMENT; RESECTION; PAIN;
D O I
10.1007/s00402-020-03403-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The most commonly used tool for implant positioning are conventional instruments (CI) followed by computer-assisted surgery (CAS). A number of studies have investigated the cutting error of the tibial component when CAS is used, but most of them were focused on the cutting angles. The accuracy of CAS to determine the depth of the cut has not received much attention, even though implications are similar or worse, than with an angle mismatch. Materials and methods This was an ethics board approved, prospective study of 23 consecutive varus TKAs by a single surgeon. Implant positioning was performed using CAS; however, the depth of the tibial cut was determined with both CAS and CI. Targeted alignment was the mechanical axis and 3 degrees of posterior slope. The planned and the achieved cut, as determined by CAS needed to match. The achieved cut was then measured using a caliper and compared to the depth of the cut as per CAS. Medial and lateral cuts were analyzed separately. Analysis of variance and Bland-Altman plots were used for the comparison. Results Mean medial navigated cut was 6.3 (+/- 2.2) mm, mean measured medial cut was 6.6 (+/- 2.3) mm. Mean lateral navigated cut was 8.9 (+/- 1.8) mm, mean measured lateral cut was 8.8 (+/- 1.5) mm. There was a statistical significance for both the medial (p < 0.001) and the lateral (p = 0.004) navigated and measured cuts. Conclusions The results of this study suggest that the tibial cut depth, measured by the navigation, does not match the actual bony cuts performed, even if a perfect cut was achieved in both sagittal and coronal plane. Surgeons should be aware of the measurement error in the navigation system and potentially add an additional step for verifying the achieved depth of the cut.
引用
收藏
页码:801 / 806
页数:6
相关论文
共 50 条
  • [21] Computer-assisted surgery can reduce blood loss after total knee arthroplasty
    Hinarejos, Pedro
    Corrales, Monica
    Matamalas, Antonia
    Bisbe, Elvira
    Caceres, Enric
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (04) : 356 - 360
  • [22] Computer-Assisted Surgery in Total Knee Arthroplasty: Our Experience
    Basavaraj, C. M.
    Raju, K. P.
    Madhuchandra, P.
    Dixith, Sandeep
    INDIAN JOURNAL OF ORTHOPAEDICS, 2024, 58 (05) : 503 - 509
  • [23] A Prospective Randomized Study to Compare Systemic Emboli Using the Computer-Assisted and Conventional Techniques of Total Knee Arthroplasty
    Malhotra, Rajesh
    Singla, Amit
    Lekha, Chandra
    Kumar, Vijay
    Karthikeyan, Ganesan
    Malik, Vishwas
    Mridha, Asit R.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (11) : 889 - 894
  • [24] Effects of computer-assisted navigation versus conventional total knee arthroplasty on the levels of inflammation markers: A prospective study
    Kuo, Shu-Jui
    Hsu, Horng-Chaung
    Wang, Ching-Jen
    Siu, Ka-Kit
    Hsu, Ya-Hung
    Ko, Jih-Yang
    Tang, Chih-Hsin
    PLOS ONE, 2018, 13 (05):
  • [25] Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty
    Huang, Tsan-Wen
    Peng, Kuo-Ti
    Huang, Kuo-Chin
    Lee, Mel S.
    Hsu, Robert Wen-Wei
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 2954 - 2961
  • [26] Computer-Assisted Surgery Is Not More Accurate or Precise Than Conventional Arthroscopic ACL Reconstruction A Prospective Randomized Clinical Trial
    Meuffels, Duncan E.
    Reijman, Max
    Verhaar, Jan A. N.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (17) : 1538 - 1545
  • [27] Conventional versus computer-assisted surgery in total knee arthroplasty: comparison at ten years follow-up
    d'Amato, Michele
    Ensini, Andrea
    Leardini, Alberto
    Barbadoro, Paolo
    Illuminati, Andrea
    Belvedere, Claudio
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (06) : 1355 - 1363
  • [28] Computer-Assisted Techniques Versus Conventional Guides for Component Alignment in Total Knee Arthroplasty
    Blakeney, William G.
    Khan, Riaz J. K.
    Wall, Simon J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15) : 1377 - 1384
  • [29] Comparative Cost Analysis of Four Different Computer-Assisted Technologies to Implant a Total Knee Arthroplasty over Conventional Instrumentation
    Christen, Bernhard
    Tanner, Lars
    Ettinger, Max
    Bonnin, Michel P.
    Koch, Peter P.
    Calliess, Tilman
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (02):
  • [30] Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique
    Pang, Hee-Nee
    Yeo, Seng-Jin
    Chong, Hwei-Chi
    Chin, Pak-Lin
    Ong, Johnny
    Lo, Ngai-Nung
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (09) : 1496 - 1503