Conventional instruments are more accurate for measuring the depth of the tibial cut than computer-assisted surgery in total knee arthroplasty: a prospective study

被引:14
|
作者
Klasan, Antonio [1 ]
Putnis, Sven Edward [1 ]
Grasso, Samuel [1 ]
Neri, Thomas [1 ]
Coolican, Myles Raphael [1 ]
机构
[1] Sydney Orthopaed Res Inst, 445 Victoria Ave, Chatswood, NSW 2067, Australia
关键词
Knee; Arthroplasty; Tibial component; Bone cut; Navigation; PATIENT-SPECIFIC INSTRUMENTATION; NAVIGATION SYSTEM; CUTTING ERRORS; REPLACEMENT; ALIGNMENT; RESECTION; PAIN;
D O I
10.1007/s00402-020-03403-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The most commonly used tool for implant positioning are conventional instruments (CI) followed by computer-assisted surgery (CAS). A number of studies have investigated the cutting error of the tibial component when CAS is used, but most of them were focused on the cutting angles. The accuracy of CAS to determine the depth of the cut has not received much attention, even though implications are similar or worse, than with an angle mismatch. Materials and methods This was an ethics board approved, prospective study of 23 consecutive varus TKAs by a single surgeon. Implant positioning was performed using CAS; however, the depth of the tibial cut was determined with both CAS and CI. Targeted alignment was the mechanical axis and 3 degrees of posterior slope. The planned and the achieved cut, as determined by CAS needed to match. The achieved cut was then measured using a caliper and compared to the depth of the cut as per CAS. Medial and lateral cuts were analyzed separately. Analysis of variance and Bland-Altman plots were used for the comparison. Results Mean medial navigated cut was 6.3 (+/- 2.2) mm, mean measured medial cut was 6.6 (+/- 2.3) mm. Mean lateral navigated cut was 8.9 (+/- 1.8) mm, mean measured lateral cut was 8.8 (+/- 1.5) mm. There was a statistical significance for both the medial (p < 0.001) and the lateral (p = 0.004) navigated and measured cuts. Conclusions The results of this study suggest that the tibial cut depth, measured by the navigation, does not match the actual bony cuts performed, even if a perfect cut was achieved in both sagittal and coronal plane. Surgeons should be aware of the measurement error in the navigation system and potentially add an additional step for verifying the achieved depth of the cut.
引用
收藏
页码:801 / 806
页数:6
相关论文
共 50 条
  • [1] Conventional instruments are more accurate for measuring the depth of the tibial cut than computer-assisted surgery in total knee arthroplasty: a prospective study
    Antonio Klasan
    Sven Edward Putnis
    Samuel Grasso
    Thomas Neri
    Myles Raphael Coolican
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 801 - 806
  • [2] Is computer-assisted surgery in total knee arthroplasty as accurate as it can be?
    Lionberger, David R.
    Crocker, Catherine L.
    Rahbar, Mohammad H.
    COMPUTER AIDED SURGERY, 2012, 17 (04) : 198 - 204
  • [3] Total knee arthroplasty with computer-assisted navigation more closely replicates normal knee biomechanics than conventional surgery
    McClelland, Jodie A.
    Webster, Kate E.
    Ramteke, Alankar A.
    Feller, Julian A.
    KNEE, 2017, 24 (03): : 651 - 656
  • [4] Outcomes of Computer-Assisted Total Knee Arthroplasty Compared to Conventional TKA: A Bicentric Controlled Retrospective Clinical Study
    Zampogna, Biagio
    Campi, Stefano
    Torre, Guglielmo
    Villari, Eleonora
    Moncada, Francesco
    Perrino, Aristide
    Ciriaco, Letterio
    Ferlazzo, Marco
    Papalia, Rocco
    Denaro, Vincenzo
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)
  • [5] Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty
    Hernandez-Vaquero, Daniel
    Noriega-Fernandez, Alfonso
    Manuel Fernandez-Carreira, Jose
    Manuel Fernandez-Simon, Jose
    Llorens de los Rios, Jimena
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 3127 - 3134
  • [6] No difference in accuracy between pinless and conventional computer-assisted surgery in total knee arthroplasty
    Baier, C.
    Maderbacher, G.
    Springorum, H. R.
    Zeman, F.
    Fitz, W.
    Schaumburger, J.
    Grifka, J.
    Beckmann, J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) : 1819 - 1826
  • [7] No difference between computer-assisted and conventional total knee arthroplasty: five-year results of a prospective randomised study
    Luetzner, Joerg
    Dexel, Julian
    Kirschner, Stephan
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2241 - 2247
  • [8] Similar outcomes in computer-assisted and conventional total knee arthroplasty: ten-year results of a prospective randomized study
    Beyer, Franziska
    Pape, Alexander
    Luetzner, Cornelia
    Kirschner, Stephan
    Luetzner, Joerg
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [9] A prospective study comparing the functional outcome of computer-assisted and conventional total knee replacement
    Hoffart, H-E.
    Langenstein, E.
    Vasak, N.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (02): : 194 - 199
  • [10] Computer-assisted total knee arthroplasty: Does the tibial component remain at malposition risk?
    Bove, J. -C.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (05) : 536 - 542