Simultaneous assessment of thermal comfort and aerodynamic drag of cycling helmets as a function of ventilation hole configuration

被引:0
|
作者
Underwood, L. [1 ]
Kiffer, T. [2 ]
Sran, H. [1 ]
Jay, K. [3 ]
Villien, A. [3 ]
Kabaliuk, N. [4 ]
Jermy, M. [4 ]
机构
[1] Ara Inst Canterbury, Dept Engn, Christchurch, New Zealand
[2] ISAE ENSMA, Chasseneuil, France
[3] Ecole Air, Salon De Provence, France
[4] Univ Canterbury, Dept Mech Engn, Christchurch 8140, New Zealand
关键词
Cycling aerodynamics; helmet design; thermal comfort; head angle; ventilation holes; QUANTIFICATION; EFFICIENCY;
D O I
10.1177/1754337119852538
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Although the main aim of cycling helmets is to protect cyclists from injury, the ideal cycling helmet minimizes aerodynamic drag and also allows rapid heat loss from the head to prevent overheating. This study takes the methods developed by Underwood et al., in which an aero helmet with reconfigurable ventilation holes was mounted on a heated mannequin head in a wind tunnel at 16.7 m/s (60 km/h) at a single angle and applies them to a range of angles representative of realistic riding positions. Thermal measurements were area weighted to provide a heat map of temperature variations over the head at different angles. Four helmet hole configurations were chosen for this study: no holes open, all holes open, front holes open and middle holes open. The results showed that the head angle had a stronger effect on drag than hole configuration. As expected, having all holes open had the greatest heat loss at any angle, but the lowest drag was found when the middle holes were open at head angles of 0 degrees and 20 degrees (at 0 degrees the neck is vertical) and all holes closed at head angles of 40 degrees and 60 degrees. The results indicate that a good venting geometry, combined with an efficient aerodynamic shape could provide an optimized helmet.
引用
收藏
页码:277 / 285
页数:9
相关论文
共 37 条
  • [31] Assessment of COVID-19 infection Risk, thermal Comfort, and energy efficiency in negative pressure isolation wards with varied ventilation modes
    Zhang, Jiaxin
    Zhao, Yanan
    Wen, Shihao
    Tu, Daixin
    Liu, Junjie
    Liu, Sumei
    ENERGY AND BUILDINGS, 2024, 308
  • [32] Quantification of Dynamic Ventilation Rates and Assessment of Occupant Thermal Comfort Inside a Naturally Ventilated Hostel Room During Wintertime in North India
    Jain, Supreme
    Addya, Asmita
    Goel, Anubha
    Lecture Notes in Civil Engineering, 2024, 380 LNCE : 103 - 117
  • [33] QUANTITATIVE ASSESSMENT OF REGIONAL PULMONARY-FUNCTION USING SIMULTANEOUS SINGLE PHOTON-EMISSION TOMOGRAPHY OF VENTILATION AND PERFUSION
    ZWIJNENBURG, A
    KLUMPER, A
    MARCUSE, HR
    JANSEN, HM
    ROOS, CM
    VANDERSCHOOT, JB
    VANZANDWIJK, N
    HOEKSTRA, A
    HOEFNAGEL, CA
    STRACKEE, J
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (2-3): : A38 - A38
  • [34] Hybrid ventilation in a nearly zero-energy building as a function of users' habits for better indoor air quality and thermal comfort in a warm climate
    Borrallo-Jimenez, Milagrosa
    Esquivias, Paula M.
    Fernandez-Agueera, Jessica
    LopezDeAsiain, Maria
    BUILDING RESEARCH AND INFORMATION, 2025, 53 (1-2): : 77 - 94
  • [36] Experimental assessment of the impact of natural ventilation on indoor air quality and thermal comfort conditions of educational buildings in the Eastern Mediterranean region during the heating period
    Heracleous, C.
    Michael, A.
    JOURNAL OF BUILDING ENGINEERING, 2019, 26
  • [37] A hybrid multibreath wash-in wash-out lung function quantification scheme in human subjects using hyperpolarized 3He MRI for simultaneous assessment of specific ventilation, alveolar oxygen tension, oxygen uptake, and air trapping
    Hamedani, Hooman
    Kadlecek, Stephen
    Xin, Yi
    Siddiqui, Sarmad
    Gatens, Heather
    Naji, Joseph
    Ishii, Masaru
    Cereda, Maurizio
    Rossman, Milton
    Rizi, Rahim
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (02) : 611 - 624