Imaging shear stress distribution and evaluating the stress concentration factor of the human eye

被引:18
作者
Antony, S. Joseph [1 ]
机构
[1] Univ Leeds, Sch Chem & Proc Engn, Inst Particle Sci & Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
HUMAN CORNEA; BIREFRINGENT PROPERTIES; POLARIZATION; ORIENTATION; PARAMETERS; TOPOGRAPHY; COLLAGEN; LENS;
D O I
10.1038/srep08899
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Healthy eyes are vital for a better quality of human life. Historically, for man-made materials, scientists and engineers use stress concentration factors to characterise the effects of structural non-homogeneities on their mechanical strength. However, such information is scarce for the human eye. Here we present the shear stress distribution profiles of a healthy human cornea surface in vivo using photo-stress analysis tomography, which is a non-intrusive and non-X-ray based method. The corneal birefringent retardation measured here is comparable to that of previous studies. Using this, we derive eye stress concentration factors and the directional alignment of major principal stress on the surface of the cornea. Similar to thermometers being used for monitoring the general health in humans, this report provides a foundation to characterise the shear stress carrying capacity of the cornea, and a potential bench mark for validating theoretical modelling of stresses in the human eye in future.
引用
收藏
页数:6
相关论文
共 33 条
[1]  
Antony S. J., 2011, KONA POWD PART J, V28, P180
[2]   Modelling the elastic properties of the anterior eye and their contribution to maintenance of image quality:: the role of the limbus [J].
Asejczyk-Widlicka, M. ;
Srodka, D. W. ;
Kasprzak, H. ;
Pierscionek, B. K. .
EYE, 2007, 21 (08) :1087-1094
[3]  
Blausen B., 2014, WIKIVERSITY J MED, V1
[4]   Lamellar orientation in human cornea in relation to mechanical properties [J].
Boote, C ;
Dennis, S ;
Huang, YF ;
Quantock, AJ ;
Meek, KM .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 149 (01) :1-6
[5]   ON THE BIREFRINGENCE OF THE LIVING HUMAN-EYE [J].
BOUR, LJ ;
CARDOZO, NJL .
VISION RESEARCH, 1981, 21 (09) :1413-1421
[6]   Measurement of parameters of polarization in the living human eye using imaging polarimetry [J].
Bueno, JM .
VISION RESEARCH, 2000, 40 (28) :3791-3799
[7]   A structural constitutive model for the human lens capsule [J].
Burd, Harvey John .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2009, 8 (03) :217-231
[8]   Can reliable values of Young's modulus be deduced from Fisher's (1971) spinning lens measurements? [J].
Burd, HJ ;
Wilde, GS ;
Judge, SJ .
VISION RESEARCH, 2006, 46 (8-9) :1346-1360
[9]  
Carney LG, 1997, INVEST OPHTH VIS SCI, V38, P311
[10]  
Dally JW, 1978, Experimental stress analysis