Transport process of outdoor particulate matter into naturally ventilated buildings

被引:22
作者
Chu, Chia-Ren [1 ]
Yang, Kai-Jie [1 ]
机构
[1] Natl Cent Univ, Dept Civil Engn, 300 Jhong Da Rd, Taoyuan 32001, Taiwan
关键词
Natural ventilation; Indoor air quality; Particulate matter; Entrance rate; Computational fluid dynamics; CROSS-VENTILATION; PARTICLE-TRANSPORT; AIR-POLLUTION; INDOOR; CFD; PERFORMANCE; DEPOSITION; PRESSURES; EXPOSURE; COMFORT;
D O I
10.1016/j.buildenv.2021.108424
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Natural ventilation of buildings can bring in fresh air, remove indoor air contaminants, and improve indoor thermal comfort. However, ventilation may also bring outdoor pollutants and/or aerosol into the buildings to affect the indoor air quality. This study uses a computational fluid dynamics model and a Lagrangian particle tracking model to investigate the transport process of outdoor particulate matter (PM) into a naturally ventilated building. The simulation results indicate that the entrance rate of outdoor PM contaminants is in the range of 7%-25%, depending on the particle size and the distance between the pollutant source and the building. The indoor concentration of PM2.5 decreases as the external wind speed and ventilation rate increase. In other words, sufficient natural ventilation can remove indoor particulate contaminants. In addition, the deposition rates in long buildings are larger than that in short buildings, owing to the sluggish airflow inside the long buildings. This study also estimates the time scales of particle deposition and ventilation-induced advection. The results reveal that the ventilation-induced airflow dominates the removal of fine particles PM1 and PM2.5, whereas the ventilation and deposition are equally important for coarse particle PM10.
引用
收藏
页数:11
相关论文
共 44 条
[31]  
Maynard R.L., 2019, HLTH EFFECTS INDOOR, P196
[32]   Particulate matter and health effects in offices - A review [J].
Nezis, Ioannis ;
Biskos, George ;
Eleftheriadis, Konstantinos ;
Kalantzi, Olga-Ioanna .
BUILDING AND ENVIRONMENT, 2019, 156 :62-73
[33]   CFD simulation of cross-ventilation for a generic isolated building: Impact of computational parameters [J].
Ramponi, R. ;
Blocken, B. .
BUILDING AND ENVIRONMENT, 2012, 53 :34-48
[34]   Pressures on a cubic building-Part 1: Full-scale results [J].
Richards, P. J. ;
Hoxey, R. P. .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2012, 102 :72-86
[35]   Wind pressures on a 6 m cube [J].
Richards, PJ ;
Hoxey, RP ;
Short, LJ .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2001, 89 (14-15) :1553-1564
[36]   The Po River Delta (North Italy) indoor epidemiological study: Effects of pollutant exposure on acute respiratory symptoms and respiratory function in adults [J].
Simoni, M ;
Carrozzi, L ;
Baldacci, S ;
Scognamiglio, A ;
Di Pede, F ;
Sapigni, T ;
Viegi, G .
ARCHIVES OF ENVIRONMENTAL HEALTH, 2002, 57 (02) :130-136
[37]   A review on interactions between energy performance of the buildings, outdoor air pollution and the indoor air quality [J].
Spiru, Paraschiv ;
Simona, Paraschiv Lizica .
INTERNATIONAL SCIENTIFIC CONFERENCE - ENVIRONMENTAL AND CLIMATE TECHNOLOGIES (CONECT 2017), 2017, 128 :179-186
[38]   Penetration of ambient submicron particles into single-family residences and associations with building characteristics [J].
Stephens, B. ;
Siegel, J. A. .
INDOOR AIR, 2012, 22 (06) :501-513
[39]   Indoor air quality in a domestic environment: Combined contribution of indoor and outdoor PM sources [J].
Tofful, Luca ;
Canepari, Silvia ;
Sargolini, Tiziana ;
Perrino, Cinzia .
BUILDING AND ENVIRONMENT, 2021, 202
[40]   AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings [J].
Tominaga, Yoshihide ;
Mochida, Akashi ;
Yoshie, Ryuichiro ;
Kataoka, Hiroto ;
Nozu, Tsuyoshi ;
Yoshikawa, Masaru ;
Shirasawa, Taichi .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2008, 96 (10-11) :1749-1761