A New Approach for Brain Source Position Estimation Based on the Eigenvalues of the EEG Sensors Spatial Covariance Matrix

被引:0
作者
Cruz, Lucas F. [1 ]
Magalhaes, Marcela G. [1 ]
Kunzler, Jonas A. [1 ]
Coelho, Andre A. S. [1 ]
Lemos, Rodrigo P. [1 ]
机构
[1] Univ Fed Goias, Sch Elect Mech & Comp Engn, Goiania, Go, Brazil
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2 | 2019年 / 68卷 / 02期
关键词
Biomedical engineering; DOA; Eigenvalues; Source estimation;
D O I
10.1007/978-981-10-9038-7_50
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Direction of Arrival (DOA) estimation methods, like MUSIC, can be applied to EEG signals for brain source localization. However, they show a severe degradation at small signal-to-noise ratios on the EEG sensors and for large amounts of brain sources. Inspired on the SEAD method, this article introduces a new method that analyses the eigenvalues of a modified spatial covariance matrix of the EEG signals to produce a two-dimensional spectrum whose peaks more robustly estimate the source positions on a horizontal section of the brain. The key approach is to select the eigenvalues that are less affected by the noise and use them to produce the spectrum. To assess the accuracy and robustness of the proposed method, we compared its root-mean-square-error performance at different noise conditions to those of MUSIC and NSF. The proposed method showed the lowest estimation errors for different amounts of brain sources and grid densities.
引用
收藏
页码:271 / 274
页数:4
相关论文
共 11 条
  • [1] Ferreira Y. R., 2005, P 8 INT S SIGN PROC, V1
  • [2] Two decades of array signal processing research - The parametric approach
    Krim, H
    Viberg, M
    [J]. IEEE SIGNAL PROCESSING MAGAZINE, 1996, 13 (04) : 67 - 94
  • [3] Kunzler J. A., 2015, P IEEE LAT AM S CIRC, P1, DOI [10.1109/LASCAS.2015.7250423, DOI 10.1109/LASCAS.2015.7250423]
  • [4] Malmivuo J., 2012, Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields
  • [5] Murzin V., 2011, ANATOMICALLY CONSTRA
  • [6] AN IMPROVED METHOD FOR LOCALIZING ELECTRIC BRAIN DIPOLES
    SALU, Y
    COHEN, LG
    ROSE, D
    SATO, S
    KUFTA, C
    HALLETT, M
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (07) : 699 - 705
  • [7] Schuele S., 2008, LANCET NEUROL
  • [8] EEG SIGNAL ANALYSIS FOR BCI INTERFACE: A REVIEW
    Vaid, Swati
    Singh, Preeti
    Kaur, Chamandeep
    [J]. 2015 5TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING & COMMUNICATION TECHNOLOGIES ACCT 2015, 2015, : 143 - 147
  • [9] Vergallo P, 2012, I CONF SENS TECHNOL, P497, DOI 10.1109/ICSensT.2012.6461729
  • [10] Vergallo P., 2013, BRAIN SOURCE LOCALIZ