The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Vibrio parahaemolyticus

被引:70
|
作者
Prompamorn, P. [1 ]
Sithigorngul, P. [1 ]
Rukpratanporn, S. [2 ]
Longyant, S. [1 ]
Sridulyakul, P. [1 ]
Chaivisuthangkura, P. [1 ]
机构
[1] Srinakharinwirot Univ, Fac Sci, Dept Biol, Bangkok 10110, Thailand
[2] Chulalongkorn Univ, Natl Ctr Genet Engn & Biotechnol BIOTEC, Ctr Excellence Marine Biotechnol, Bangkok, Thailand
关键词
loop-mediated isothermal amplification (LAMP); PCR; tlh gene; Vibrio parahaemolyticus; THERMOSTABLE DIRECT HEMOLYSIN; RAPID DETECTION; SENSITIVE DETECTION; GENE; TDH; SHELLFISH; CHOLERAE; STRAINS; O3-K6; ASSAY;
D O I
10.1111/j.1472-765X.2011.03007.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Aims: The current study was aimed to develop a loop-mediated isothermal amplification (LAMP) combined with amplicon detection by chromatographic lateral flow dipstick (LFD) assay for rapid and specific detection of Vibrio parahaemolyticus. Methods and Results: Biotinylated LAMP amplicons were produced by a set of four designed primers that recognized specifically the V. parahaemolyticus thermolabile haemolysin (tlh) gene followed by hybridization with an FITC-labelled probe and LFD detection. The optimized time and temperature conditions for the LAMP assay were 90 min at 65 degrees C. The LAMP-LFD method accurately identified 28 isolates of V. parahaemolyticus but did not detect 24 non-parahaemolyticus Vibrio isolates and 35 non-Vibrio bacterial isolates. The sensitivity of LAMP-LFD for V. parahaemolyticus detection in pure cultures was 120 CFU ml-1. In the case of spiked shrimp samples without enrichment, the detection limit for V. parahaemolyticus was 1 center dot 8 x 103 CFU g-1 or equivalent to 3 CFU per reaction while that of conventional PCR was 30 CFU per reaction. Conclusions: The established LAMP-LFD assay targeting tlh gene was specific, rapid and sensitive for identification of V. parahaemolyticus. Significance and Impact of the Study: The developed LAMP-LFD assay provided a valuable tool for detection of V. parahaemolyticus and can be used effectively for identification of V. parahaemolyticus in contaminated food sample.
引用
收藏
页码:344 / 351
页数:8
相关论文
共 50 条
  • [21] Rapid and Sensitive Detection of Salmonella in Chickens Using Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick
    Liu, Zhi-Ke
    Zhang, Qiu-Yu
    Yang, Ning-Ning
    Xu, Ming-Guo
    Xu, Jin-Feng
    Jing, Ming-Long
    Wu, Wen-Xing
    Lu, Ya-Dong
    Shi, Feng
    Chen, Chuang-Fu
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2019, 29 (03) : 454 - 464
  • [22] Loop-Mediated Isothermal Amplification Combined With Lateral-Flow Dipstick for Detection of Centrocestus formosanus in Ornamental Fish
    Sabaijai, Metawee
    Tejangkura, Thanawan
    Chontananarth, Thapana
    JOURNAL OF FISH DISEASES, 2025, 48 (04)
  • [23] Application of loop-mediated isothermal amplification combined with lateral flow dipstick to rapid and sensitive detection of Alexandrium catenella
    Wang, Liang
    Chen, Guofu
    Zhang, Chunyun
    Wang, Yuanyuan
    Sun, Rui
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (04) : 4246 - 4257
  • [24] Improvement and evaluation of loop-mediated isothermal amplification combined with a chromatographic flow dipstick assay and utilization in detection of Vibrio cholerae
    Jia Yu
    Feixue Wang
    Xijing Zhan
    Xin Wang
    Feng Zuo
    Yuxi Wei
    Jun Qi
    Yin Liu
    Analytical and Bioanalytical Chemistry, 2019, 411 : 647 - 658
  • [25] Improvement and evaluation of loop-mediated isothermal amplification combined with a chromatographic flow dipstick assay and utilization in detection of Vibrio cholerae
    Yu, Jia
    Wang, Feixue
    Zhan, Xijing
    Wang, Xin
    Zuo, Feng
    Wei, Yuxi
    Qi, Jun
    Liu, Yin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (03) : 647 - 658
  • [26] Rapid and sensitive detection of Vibrio harveyi by loop-mediated isothermal amplification combined with lateral flow dipstick targeted to vhhP2 gene
    Thongkao, Kanittada
    Longyant, Siwaporn
    Silprasit, Kun
    Sithigorngul, Paisarn
    Chaivisuthangkura, Parin
    AQUACULTURE RESEARCH, 2015, 46 (05) : 1122 - 1131
  • [27] Development of the Visual Loop-Mediated Isothermal Amplification Combined with Lateral Flow Dipstick (LAMP-LFD) Method for Rapid Detection of Vibrio harveyi in Aquatic Animals
    Cai, S. H.
    Chen, Z.
    Sun, L. J.
    Zhong, J.
    Huang, Y. C.
    Yang, S. P.
    Lu, Y. S.
    APPLIED BIOCHEMISTRY AND MICROBIOLOGY, 2024, 60 (04) : 749 - 756
  • [28] A loop-mediated isothermal amplification method for rapid detection of Vibrio parahaemolyticus in seafood
    Xiaohong Sun
    Qian Xu
    Yingjie Pan
    Weiqing Lan
    Yong Zhao
    Vivian C. H. Wu
    Annals of Microbiology, 2012, 62 : 263 - 271
  • [29] A loop-mediated isothermal amplification method for rapid detection of Vibrio parahaemolyticus in seafood
    Sun, Xiaohong
    Xu, Qian
    Pan, Yingjie
    Lan, Weiqing
    Zhao, Yong
    Wu, Vivian C. H.
    ANNALS OF MICROBIOLOGY, 2012, 62 (01) : 263 - 271
  • [30] Development and Application of in Situ Loop-Mediated Isothermal Amplification Method for Detection of Vibrio Parahaemolyticus in Foods
    Wang, Li
    Zhong, Qingping
    Qiu, Haiqiang
    Shi, Lei
    ISBE 2011: 2011 INTERNATIONAL CONFERENCE ON BIOMEDICINE AND ENGINEERING, VOL 4, 2011, : 278 - 281