The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Vibrio parahaemolyticus

被引:70
|
作者
Prompamorn, P. [1 ]
Sithigorngul, P. [1 ]
Rukpratanporn, S. [2 ]
Longyant, S. [1 ]
Sridulyakul, P. [1 ]
Chaivisuthangkura, P. [1 ]
机构
[1] Srinakharinwirot Univ, Fac Sci, Dept Biol, Bangkok 10110, Thailand
[2] Chulalongkorn Univ, Natl Ctr Genet Engn & Biotechnol BIOTEC, Ctr Excellence Marine Biotechnol, Bangkok, Thailand
关键词
loop-mediated isothermal amplification (LAMP); PCR; tlh gene; Vibrio parahaemolyticus; THERMOSTABLE DIRECT HEMOLYSIN; RAPID DETECTION; SENSITIVE DETECTION; GENE; TDH; SHELLFISH; CHOLERAE; STRAINS; O3-K6; ASSAY;
D O I
10.1111/j.1472-765X.2011.03007.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Aims: The current study was aimed to develop a loop-mediated isothermal amplification (LAMP) combined with amplicon detection by chromatographic lateral flow dipstick (LFD) assay for rapid and specific detection of Vibrio parahaemolyticus. Methods and Results: Biotinylated LAMP amplicons were produced by a set of four designed primers that recognized specifically the V. parahaemolyticus thermolabile haemolysin (tlh) gene followed by hybridization with an FITC-labelled probe and LFD detection. The optimized time and temperature conditions for the LAMP assay were 90 min at 65 degrees C. The LAMP-LFD method accurately identified 28 isolates of V. parahaemolyticus but did not detect 24 non-parahaemolyticus Vibrio isolates and 35 non-Vibrio bacterial isolates. The sensitivity of LAMP-LFD for V. parahaemolyticus detection in pure cultures was 120 CFU ml-1. In the case of spiked shrimp samples without enrichment, the detection limit for V. parahaemolyticus was 1 center dot 8 x 103 CFU g-1 or equivalent to 3 CFU per reaction while that of conventional PCR was 30 CFU per reaction. Conclusions: The established LAMP-LFD assay targeting tlh gene was specific, rapid and sensitive for identification of V. parahaemolyticus. Significance and Impact of the Study: The developed LAMP-LFD assay provided a valuable tool for detection of V. parahaemolyticus and can be used effectively for identification of V. parahaemolyticus in contaminated food sample.
引用
收藏
页码:344 / 351
页数:8
相关论文
共 50 条
  • [1] Development of Vibrio parahaemolyticus sensitive and specific loop-mediated isothermal amplification combined with lateral flow device
    Liang, Xiaoheng
    Zhan, Dan
    Huang, Xin
    Bi, Jinli
    Li, Jinghan
    Meng, Liqin
    Xie, Li
    Li, Taijie
    BIOMEDICAL PAPERS-OLOMOUC, 2025,
  • [2] The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Karlodinium veneficum
    Huang, Hai-Long
    Zhu, Peng
    Zhou, Cheng-Xu
    He, Shan
    Yan, Xiao-Jun
    HARMFUL ALGAE, 2017, 62 : 20 - 29
  • [3] Improvement and evaluation of loop-mediated isothermal amplification combined with chromatographic flow dipstick assays for Vibrio parahaemolyticus
    Xing, Jiahua
    Yu, Jia
    Liu, Yin
    JOURNAL OF MICROBIOLOGICAL METHODS, 2020, 171
  • [4] Development of Duplex Loop-Mediated Isothermal Amplification (dLAMP) Combined with Lateral Flow Dipstick (LFD) for the Rapid and Specific Detection of Vibrio vulnificus and V. parahaemolyticus
    Pasookhush, Phongthana
    Longyant, Siwaporn
    Sithigorngul, Paisarn
    Chaivisuthangkura, Parin
    NORTH AMERICAN JOURNAL OF AQUACULTURE, 2016, 78 (04) : 327 - 336
  • [5] Detection of Skeletonema costatum based on loop-mediated isothermal amplification combined with lateral flow dipstick
    Huang, Hai-Long
    Zhu, Peng
    Zhou, Cheng-Xu
    Yan, Xiao-Jun
    Zou, Yi-Xin
    Lv, Pei-Wen
    MOLECULAR AND CELLULAR PROBES, 2017, 36 : 36 - 42
  • [6] Rapid and Sensitive Detection of Vibrio alginolyticus by Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick Targeted to the rpoX Gene
    Plaon, Saranya
    Longyant, Siwaporn
    Sithigorngul, Paisarn
    Chaivisuthangkura, Parin
    JOURNAL OF AQUATIC ANIMAL HEALTH, 2015, 27 (03) : 156 - 163
  • [7] Rapid and sensitive detection of Vibrio vulnificus by loop-mediated isothermal amplification combined with lateral flow dipstick targeted to rpoS gene
    Surasilp, Thanai
    Longyant, Siwaporn
    Rukpratanporn, Sombat
    Sridulyakul, Pattarin
    Sithigorngul, Paisarn
    Chaivisuthangkura, Parin
    MOLECULAR AND CELLULAR PROBES, 2011, 25 (04) : 158 - 163
  • [8] Detection of Roundup Ready soybean by loop-mediated isothermal amplification combined with a lateral-flow dipstick
    Wang, Xiumin
    Teng, Da
    Guan, Qingfeng
    Tian, Fang
    Wang, Jianhua
    FOOD CONTROL, 2013, 29 (01) : 213 - 220
  • [9] Repaid and Accurate Detection of Khuskia oryzae by Loop-mediated isothermal Amplification Combined with a Lateral Flow Dipstick
    Xiong Yun
    Yang Hao
    Zhu Peng
    Huang Hailong
    He Qianqian
    Zhou Jian
    IAEDS15: INTERNATIONAL CONFERENCE IN APPLIED ENGINEERING AND MANAGEMENT, 2015, 46 : 877 - 882
  • [10] Rapid and sensitive detection of Karenia mikimotoi by loop-mediated isothermal amplification combined with a lateral flow dipstick
    Han, Xiaotian
    Zhao, Ting
    Yan, Tian
    Yu, Rencheng
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (17) : 24696 - 24703