Ultrasound dilution evaluation of pediatric hemodialysis vascular access

被引:3
作者
Goldstein, SL
Allsteadt, A
机构
[1] Texas Childrens Hosp, Houston, TX 77030 USA
[2] Baylor Coll Med, Houston, TX USA
关键词
venogram; dialysis access; stenosis; blood flow; thrombosis; noninvasive measurement; children and dialysis;
D O I
10.1046/j.1523-1755.2001.00753.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background. Hemodialysis access thrombosis is a significant cause of morbidity for hemodialysis patients and results from decreased access flow caused by venous outflow tract stenosis. Ultrasound dilution (UD) is a practical, noninvasive, and reliable indicator of access flow and is effective in predicting venous stenosis in adult patients receiving hemodialysis. Methods. The current study is the first to our knowledge to evaluate the accuracy of UD in predicting hemodialysis access stenosis in a pediatric hemodialysis population. Thirteen pediatric patients receiving hemodialysis via permanent access (4 AVF and 9 AVG) received 73 UD measurements over three months. Results. Mean raw access flow (QA) was 720 +/- 428 mL/ min, and mean corrected access flow (QAcorr) was 886 +/- 537 mL/min/1.73 m(2). QAcorr was significantly lower in accesses with stenosis (401 +/- 176 mL/min/1.73 m(2)) versus accesses with out stenosis (1158 +/- 330 mL/min/1.73 m(2), P < 0.0001). Unlike flow values reported by raw QA, there was no overlap in flow values reported by QAcorr in accesses with stenosis (174 to 579 mL/min/1.73 m(2)) versus accesses without stenosis (708 to 1711 mL/min/1.73 m(2)). Two patients with an AVG who had QAcorr less than 600 mL/min/1.73 m(2) developed an access thrombosis within one week after UD measurement. No patients with QAcorr greater than 700 mL/min/1.73 m(2) developed access thrombosis in the 30 days following UD measurement. Conclusions. The current study supports the use of monthly UD measurement to prevent access thrombosis in children receiving hemodialysis.
引用
收藏
页码:2357 / 2360
页数:4
相关论文
共 20 条
[1]  
Albers F J, 1994, Adv Ren Replace Ther, V1, P107
[2]   The relationship of recirculation to access blood flow [J].
Besarab, A ;
Sherman, R .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 29 (02) :223-229
[3]   A prospective evaluation of PTFE graft patency and surveillance techniques in hemodialysis access [J].
Cinat, ME ;
Hopkins, J ;
Wilson, SE .
ANNALS OF VASCULAR SURGERY, 1999, 13 (02) :191-198
[4]  
DAUGIRDAS JT, 1993, J AM SOC NEPHROL, V4, P1205
[5]   HEMODIALYSIS GRAFTS - COLOR DOPPLER FLOW IMAGING CORRELATED WITH DIGITAL SUBTRACTION ANGIOGRAPHY AND FUNCTIONAL STATUS [J].
DOUSSET, V ;
GRENIER, N ;
DOUWS, C ;
SENUITA, P ;
SASSOUSTE, G ;
ADA, L ;
POTAUX, L .
RADIOLOGY, 1991, 181 (01) :89-94
[6]   Natural logarithmic estimates of Kt/V in the pediatric hemodialysis population [J].
Goldstein, SL ;
Sorof, JM ;
Brewer, ED .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 33 (03) :518-522
[7]   Logarithmic extrapolation of a 15-minute postdialysis BUN to predict equilibrated BUN and calculate double-pool Kt/V in the pediatric hemodialysis population [J].
Goldstein, SL ;
Brewer, ED .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 36 (01) :98-104
[8]   The impact of the Dialysis Outcomes Quality Initiative Guidelines on the care of the pediatric end-stage renal disease patient [J].
Jabs, K ;
Warady, BA .
ADVANCES IN RENAL REPLACEMENT THERAPY, 1999, 6 (01) :97-106
[9]   DIALYSIS ACCESS GRAFTS - ANATOMIC LOCATION OF VENOUS STENOSIS AND RESULTS ANGIOPLASTY [J].
KANTERMAN, RY ;
VESELY, TM ;
PILGRAM, TK ;
GUY, BW ;
WINDUS, DW ;
PICUS, D .
RADIOLOGY, 1995, 195 (01) :135-139
[10]   THEORY AND VALIDATION OF ACCESS FLOW MEASUREMENT BY DILUTION TECHNIQUE DURING HEMODIALYSIS [J].
KRIVITSKI, NM .
KIDNEY INTERNATIONAL, 1995, 48 (01) :244-250