Effects of Temperature and Blinking on Contact Lens Dehydration of Contemporary Soft Lens Materials Using an In Vitro Blink Model

被引:4
作者
Chan, Vivian W. Y. [1 ]
Phan, Chau-Minh [1 ,2 ]
Walther, Hendrik [1 ]
Ngo, William [1 ,2 ]
Jones, Lyndon [1 ,2 ]
机构
[1] Univ Waterloo, Sch Optometry & Vis Sci, Ctr Ocular Res & Educ CORE, Waterloo, ON, Canada
[2] Ctr Eye & Vis Res CEVR, Hong Kong, Peoples R China
关键词
contact lens; dehydration; in vitro; eye model; blinking; COMFORT; PERIODS; WATER;
D O I
10.1167/tvst.10.8.11
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to evaluate the effects of temperature and blink -ing on contact lens (CL) dehydration using an in vitro blink model. Methods: Three silicone hydrogel (delefilcon A, senofilcon A, and comfilcon A) and two conventional hydrogel (etafilcon A and omafilcon A) CL materials were evaluated at 1 and 16 hours. The water content (WC) of the CLs was measured using a gravimetric method. Lenses were incubated on a blink model, internally heated to achieve a clini-cally relevant surface temperature of 35 degrees C. An artificial tear solution (ATS) was delivered to the blink model at 4.5 mu L/min with a blink rate of 6 blinks/min. A comparison set of lenses were incubated in a vial containing either 2 mL of ATS or phosphate-buffered saline (PBS) at 35 degrees C. Results: Increasing temperature to 35 degrees C resulted in a decrease in WC for all tested CLs over time (P <= 0.0052). For most CLs, there was no significant difference in WC over time between ATS or PBS in the vial (P > 0.05). With the vial system, WC decreased and plateaued over time. However, on the blink model, for most CLs, the WC significantly decreased after 1 hour but returned toward initial WC levels after 16 hours (P > 0.05). Conclusions: The reduction in WC of CLs on the eye is likely due to both an increase in temperature and dehydration from air exposure and blinking. Translational Relevance: This study showed that the novel, heated, in vitro blink model could be used to provide clinical insights into CL dehydration on the eye.
引用
收藏
页数:12
相关论文
共 32 条
[21]   Ocular Discomfort Responses after Short Periods of Contact Lens Wear [J].
Papas, Eric ;
Tilia, Daniel ;
McNally, John ;
de la Jara, Percy Lazon .
OPTOMETRY AND VISION SCIENCE, 2015, 92 (06) :665-670
[22]  
Pruitt J, 2013, DEV DAILIES TOTAL1 W
[23]  
Quesnel N M, 2001, Cont Lens Anterior Eye, V24, P88, DOI 10.1016/S1367-0484(01)80022-9
[24]   Characterisation of hydrogels: Linking the nano to the microscale [J].
Raghuwanshi, Vikram Singh ;
Garnier, Gil .
ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2019, 274
[25]  
Ramamoorthy P, 2010, OPHTHAL PHYSL OPT, V30, P160, DOI [10.1111/j.1475-1313.2009.00705.x, 10.1111/J.1475-1313.2009.00705.X]
[26]   Effect of Short Recovery Periods on Ocular Comfort During Daily Lens Wear [J].
Stahl, Ulrike ;
Keir, Nancy J. ;
Landers, Alan ;
Jones, Lyndon W. .
OPTOMETRY AND VISION SCIENCE, 2016, 93 (08) :861-871
[27]   Automated study of ocular thermal images: Comprehensive analysis of corneal health with different age group subjects and validation [J].
Tan, Jen-Hong ;
Ng, E. Y. K. ;
Acharya, Rajendra U. ;
Chee, C. .
DIGITAL SIGNAL PROCESSING, 2010, 20 (06) :1579-1591
[28]  
Tighe B, 2018, CONTACT LENS MAT CON
[29]  
Tranoudis Ioannis, 2004, Cont Lens Anterior Eye, V27, P193, DOI 10.1016/j.clae.2004.08.003
[30]   Differential Deposition of Fluorescently Tagged Cholesterol on Commercial Contact Lenses Using a Novel In Vitro Eye Model [J].
Walther, Hendrik ;
Chau-Minh Phan ;
Subbaraman, Lakshman N. ;
Jones, Lyndon .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (02)