Effects of Temperature and Blinking on Contact Lens Dehydration of Contemporary Soft Lens Materials Using an In Vitro Blink Model

被引:4
作者
Chan, Vivian W. Y. [1 ]
Phan, Chau-Minh [1 ,2 ]
Walther, Hendrik [1 ]
Ngo, William [1 ,2 ]
Jones, Lyndon [1 ,2 ]
机构
[1] Univ Waterloo, Sch Optometry & Vis Sci, Ctr Ocular Res & Educ CORE, Waterloo, ON, Canada
[2] Ctr Eye & Vis Res CEVR, Hong Kong, Peoples R China
关键词
contact lens; dehydration; in vitro; eye model; blinking; COMFORT; PERIODS; WATER;
D O I
10.1167/tvst.10.8.11
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to evaluate the effects of temperature and blink -ing on contact lens (CL) dehydration using an in vitro blink model. Methods: Three silicone hydrogel (delefilcon A, senofilcon A, and comfilcon A) and two conventional hydrogel (etafilcon A and omafilcon A) CL materials were evaluated at 1 and 16 hours. The water content (WC) of the CLs was measured using a gravimetric method. Lenses were incubated on a blink model, internally heated to achieve a clini-cally relevant surface temperature of 35 degrees C. An artificial tear solution (ATS) was delivered to the blink model at 4.5 mu L/min with a blink rate of 6 blinks/min. A comparison set of lenses were incubated in a vial containing either 2 mL of ATS or phosphate-buffered saline (PBS) at 35 degrees C. Results: Increasing temperature to 35 degrees C resulted in a decrease in WC for all tested CLs over time (P <= 0.0052). For most CLs, there was no significant difference in WC over time between ATS or PBS in the vial (P > 0.05). With the vial system, WC decreased and plateaued over time. However, on the blink model, for most CLs, the WC significantly decreased after 1 hour but returned toward initial WC levels after 16 hours (P > 0.05). Conclusions: The reduction in WC of CLs on the eye is likely due to both an increase in temperature and dehydration from air exposure and blinking. Translational Relevance: This study showed that the novel, heated, in vitro blink model could be used to provide clinical insights into CL dehydration on the eye.
引用
收藏
页数:12
相关论文
共 32 条
[1]  
BRENNAN NA, 1988, AM J OPTOM PHYS OPT, V65, P277
[2]   INVIVO DEHYDRATION OF DISPOSABLE (ACUVUE) CONTACT-LENSES [J].
BRENNAN, NA ;
LOWE, R ;
EFRON, N ;
HARRIS, MG .
OPTOMETRY AND VISION SCIENCE, 1990, 67 (03) :201-203
[3]   The role of tear physiology in ocular surface temperature [J].
Craig, JP ;
Singh, I ;
Tomlinson, A ;
Morgan, PB ;
Efron, N .
EYE, 2000, 14 (4) :635-641
[4]   The TFOS International Workshop on Contact Lens Discomfort: Report of the Subcommittee on Epidemiology [J].
Dumbleton, Kathy ;
Caffery, Barbara ;
Dogru, Murat ;
Hickson-Curran, Sheila ;
Kern, Jami ;
Kojima, Takashi ;
Morgan, Philip B. ;
Purslow, Christine ;
Robertson, Danielle M. ;
Nelson, J. Daniel .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (11) :20-36
[5]   DEHYDRATION OF HYDROGEL CONTACT-LENSES INVITRO AND INVIVO [J].
EFRON, N ;
YOUNG, G .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1988, 8 (03) :253-256
[6]  
EFRON N, 1989, CURR EYE RES, V8, P901
[7]   Hydrogel lens dehydration and subjective comfort and dryness ratings in symptomatic and asymptomatic contact lens wearers [J].
Fonn, D ;
Situ, P ;
Simpson, T .
OPTOMETRY AND VISION SCIENCE, 1999, 76 (10) :700-704
[8]  
Hall Brenda, 1999, CLAO Journal, V25, P233
[9]   POLY(VINYL ALCOHOL) HYDROGELS AS SOFT CONTACT-LENS MATERIAL [J].
HYON, SH ;
CHA, WI ;
IKADA, Y ;
KITA, M ;
OGURA, Y ;
HONDA, Y .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1994, 5 (05) :397-406
[10]  
Jones L, 2002, Cont Lens Anterior Eye, V25, P147, DOI 10.1016/S1367-0484(02)00033-4