Lanthanum-selective membrane electrode based on 2,2′-dithiodipyridine

被引:40
作者
Akhond, M [1 ]
Najafi, MB [1 ]
Tashkhourian, J [1 ]
机构
[1] Shiraz Univ, Dept Chem, Shiraz 71454, Iran
关键词
lanthanum ion-selective electrode; 2,2 '-dithiodipyridine; PVC membrane; potentiometry; fluoride determination;
D O I
10.1016/j.aca.2004.09.089
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a new poly(vinyl chloride) (PVC) membrane sensor for La3+ ion based on 2,2'-dithiodipyridine as an ion carrier was prepared. This electrode revealed good selectivity for La3+ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, the amount of additive and concentration of internal solution on the potential response of La3+ sensor were investigated. The electrode exhibited a Nernstian slope of 20.0 +/- 1.0 mV per decade of La3+ over a concentration range of 7.1 x 10(-6) to 2.2 x 10(-2) M of La3+ in the pH range 3.3-8.0. The response time was about 7 s and the detection limit was 3.1 x 10(-6) M. The electrode can be used for at least 2 months without a considerable divergence in potential. The proposed electrode was used as an indicator electrode in potentiometric titration of oxalate and fluoride ions and was applied for determination of F- ion in mouthwash solution. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 37 条
[1]  
Amarchand S, 2000, ELECTROANAL, V12, P522, DOI 10.1002/(SICI)1521-4109(200005)12:7<522::AID-ELAN522>3.0.CO
[2]  
2-D
[3]  
AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
[4]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[5]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[6]   TRANSDUCTION OF SELECTIVE RECOGNITION OF HEAVY-METAL IONS BY CHEMICALLY MODIFIED FIELD-EFFECT TRANSISTORS (CHEMFETS) [J].
COBBEN, PLHM ;
EGBERINK, RJM ;
BOMER, JG ;
BERGVELD, P ;
VERBOOM, W ;
REINHOUDT, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (26) :10573-10582
[7]   DETERMINATION OF RARE-EARTH ELEMENTS IN GEOLOGICAL-MATERIALS BY INDUCTIVELY COUPLED ARGON PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CROCK, JG ;
LICHTE, FE .
ANALYTICAL CHEMISTRY, 1982, 54 (08) :1329-1332
[8]   SELECTIVITY-MODIFYING INFLUENCE OF ANIONIC SITES IN NEUTRAL-CARRIER-BASED MEMBRANE ELECTRODES [J].
EUGSTER, R ;
GEHRIG, PM ;
MORF, WE ;
SPICHIGER, UE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2285-2289
[9]   MEMBRANE MODEL FOR NEUTRAL-CARRIER-BASED MEMBRANE ELECTRODES CONTAINING IONIC SITES [J].
EUGSTER, R ;
SPICHIGER, UE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1993, 65 (06) :689-695
[10]   PVC-based hexathia-18-crown-6-tetraone sensor for mercury(II) ions [J].
Fakhari, AR ;
Ganjali, MR ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3693-3696