Pseudo-dynamic tests on full-scale two storeys RC frames with different infill-to-structure connections

被引:9
作者
Del Vecchio, C. [1 ]
Di Ludovico, M. [2 ]
Verderame, G. M. [2 ]
Prota, A. [2 ]
机构
[1] Univ Sannio, Dept Engn, Piazza Roma 21, I-82100 Benevento, Italy
[2] Univ Napoli Feder II, Dept Struct Engn & Architecture, Via Claudio 21, I-80125 Naples, Italy
关键词
Seismicassessment; Existingbuildings; Infilled; Shear; Experimental; Fragility; SHEAR-STRENGTH; DAMAGE ASSESSMENT; REPAIR COSTS; MASONRY; BEHAVIOR; MODEL;
D O I
10.1016/j.engstruct.2022.114608
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Field surveys showed that the fabrication of infill, with particular emphasis on the connection with the sur-rounding reinforced concrete (RC) frame, may have a significant influence on the global response, earthquake damage and on the actions transmitted to the surrounding RC members.This study reports and discusses the outcomes of an experimental program on three two-storeys full-scale infilled RC frames varying the concrete strength and infill-to-structure connection. The specimens were subjected to pseudo-dynamic tests at increasing intensity to characterize the frame response and the related damage states. The results showed that the strength and stiffness of the frame increase by increasing the infill-to-structures connection. The enhanced connection allows to have a better loading transfer from the structure to the infill with a strength increase ranging between 10% and 30%. This resulted in a reduction of the displacement demand and in an increase of the shear force transmitted to the top of the column. The results are compared with the damage observed during post-earthquake field survey at building level and with available fragility functions showing a good matching. A non-linear FEM model is proposed to capture the lateral response of the tested frames and the results are compared and discussed. The comparison outlines the reliability of a three-strut model to accurately reproduce the infill response and the shear actions transmitted at the top of the columns.
引用
收藏
页数:16
相关论文
共 39 条
[21]   Repair Costs of Existing RC Buildings Damaged by the L'Aquila Earthquake and Comparison with FEMA P-58 Predictions [J].
Del Vecchio, Ciro ;
Di Ludovico, Marco ;
Pampanin, Stefano ;
Prota, Andrea .
EARTHQUAKE SPECTRA, 2018, 34 (01) :237-263
[22]  
Kowalsky MJ, 2000, ACI STRUCT J, V97, P388
[23]   In-plane response of masonry infill walls: Comprehensive experimentally-based equivalent strut model for deterministic and probabilistic analysis [J].
Liberatore, Laura ;
Noto, Fabrizio ;
Mollaioli, Fabrizio ;
Franchin, Paolo .
ENGINEERING STRUCTURES, 2018, 167 :533-548
[24]  
Magenes G., 2004, P 13 WORLD C EARTHQ
[25]  
Mainstone RJ, 1971, P I CIVIL ENG, P57
[26]  
Ministry of Health Kenya, 2018, National Family Planning Guidelines for Service Providers, P1
[27]  
Molitierno C., 2021, 2 FIB IT YMG S CONCR, P109
[28]   Performance-based interpretation of in-plane cyclic tests on RC frames with strong masonry infills [J].
Morandi, Paolo ;
Hak, Sanja ;
Magenes, Guido .
ENGINEERING STRUCTURES, 2018, 156 :503-521
[29]  
Negro P, 1996, EARTHQUAKE ENG STRUC, V25, P753
[30]  
New Zealand Society for Earthquake Engineering (NZSEE), 2017, Technical Guidelines for Installing Elevators in Existing Multi-Storey Residential Buildings in Shenzhen