Use of an inclinometer to measure flexibility of the iliotibial band using the. Ober test and the modified Ober test: Differences in magnitude and reliability of measurements

被引:62
作者
Reese, NB
Bandy, WD
机构
[1] Univ Cent Arkansas, Dept Phys Therapy, Conway, AR 72035 USA
[2] Univ Cent Arkansas, Dept Anaesthesia, Conway, AR 72035 USA
关键词
D O I
10.2519/jospt.2003.33.6.326
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Test-retest design to evaluate the reliability of the measurement of iliotibial (IT) band flexibility using an inclinometer to measure the hip adduction angle. Objectives: The primary objective was to determine the intrarater reliability of the Ober test and the modified Ober test for the assessment of IT band flexibility using an inclinometer to measure the hip adduction angle. A secondary objective was to determine if a difference existed between the measurements of IT band flexibility between the Ober and modified Ober test. Background: The Ober test and the modified Ober test are frequently used for the measurement of IT band flexibility. To date, data documenting the objective measurement of flexibility of the IT band is scarce in the literature. Methods and Measures: Sixty-one subjects, with a mean age of 24.2 (SD = 4.3) years, were measured during 2 measurement sessions over 2 consecutive days. During each measurement session, subjects were positioned on their left side and, with an inclinometer at the lateral epicondyle of the femur, hip adduction was measured during the Ober test (knee at 90degrees of flexion) and the modified Ober test (knee extended). If the limb was horizontal, it was considered to be at 0degrees, if below horizontal (adducted), it was recorded as a positive number, and if above horizontal (abducted), it was recorded as a negative number. Results: The ICC values calculated for the intrarater reliability of the repeated measurement were 0.90 for the Ober test and 0.91 for the modified Ober test. Results of the dependent t test indicated a significantly greater range of motion of the hip in adduction using the modified Ober test as compared to the Ober test. Discussion and Conclusion: The use of an inclinometer to measure hip adduction using both the Ober test and the modified Ober test appears to be a reliable method for the measurement of IT band flexibility, and the technique is quite easy to use. However, given that the modified Ober test allows significantly greater hip adduction range of motion than the Ober test, the 2 examination procedures should not be used interchangeably for the measurement of the flexibility of the IT band.
引用
收藏
页码:326 / 330
页数:5
相关论文
共 27 条
  • [1] [Anonymous], 2002, Joint Range of Motion and Muscle Length Testing
  • [2] Clemente C.D., 1985, GRAYS ANATOMY
  • [3] CURRIER DP, 1984, ELEMENTS RES PHYSL T
  • [4] THE EFFECT OF EXERCISE ON PATELLAR TRACKING IN LATERAL PATELLAR COMPRESSION SYNDROME
    DOUCETTE, SA
    GOBLE, EM
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (04) : 434 - 440
  • [5] MAGNETIC-RESONANCE-IMAGING OF ILIOTIBIAL BAND SYNDROME
    EKMAN, EF
    POPE, T
    MARTIN, DF
    CURL, WW
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (06) : 851 - 854
  • [6] GONIOMETRIC RELIABILITY IN A CLINICAL SETTING - SUBTALAR AND ANKLE JOINT MEASUREMENTS
    ELVERU, RA
    ROTHSTEIN, JM
    LAMB, RL
    [J]. PHYSICAL THERAPY, 1988, 68 (05): : 672 - 677
  • [7] EQUIVALENCE OF WEIGHTED KAPPA AND INTRACLASS CORRELATION COEFFICIENT AS MEASURES OF RELIABILITY
    FLEISS, JL
    COHEN, J
    [J]. EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1973, 33 (03) : 613 - 619
  • [8] Gajdosik RL, 2003, CLIN BIOMECH, V18, P77
  • [9] GOSE J C, 1989, Journal of Orthopaedic and Sports Physical Therapy, V10, P399
  • [10] Hilyard A., 1990, PHYSIOTHERAPY, V76, P559, DOI [10.1016/S0031-9406(10)63047-7, DOI 10.1016/S0031-9406(10)63047-7]