Augmented Reality Guidance System for Peripheral Nerve Blocks

被引:0
作者
Wedlake, Chris [1 ]
Moore, John [1 ]
Rachinsky, Maxim [2 ]
Bainbridge, Daniel [2 ]
Wiles, Andrew D. [1 ,3 ,4 ]
Peters, Terry M. [1 ,4 ,5 ]
机构
[1] Robarts Res Inst, Imaging Res Lab, London, ON N6A 5C1, Canada
[2] Univ Western Ontario, Dept Anesthesia & Perioperat Med, London, ON, Canada
[3] Northern Digital Inc, Waterloo, ON, Canada
[4] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[5] CSTAR, London, ON, Canada
来源
MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING | 2010年 / 7625卷
关键词
augmented reality; nerve block; tracking system; tracked ultrasound; tracked needle; needle bending; GUIDED REGIONAL ANESTHESIA; ULTRASOUND; VISUALIZATION;
D O I
10.1117/12.844410
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Peripheral nerve block treatments are ubiquitous in hospitals and pain clinics worldwide. State of the art techniques use ultrasound (US) guidance and/or electrical stimulation to verify needle tip location. However, problems such as needle-US beam alignment, poor echogenicity of block needles and US beam thickness can make it difficult for the anesthetist to know the exact needle tip location. Inaccurate therapy delivery raises obvious safety and efficacy issues. We have developed and evaluated a needle guidance system that makes use of a magnetic tracking system (MTS) to provide an augmented reality (AR) guidance platform to accurately localize the needle tip as well as its projected trajectory. Five anesthetists and five novices performed simulated nerve block deliveries in a polyvinyl alcohol phantom to compare needle guidance under US alone to US placed in our AR environment. Our phantom study demonstrated a decrease in targeting attempts, decrease in contacting of critical structures, and an increase in accuracy of 0.68 mm compared to 1.34mm RMS in US guidance alone. Currently, the MTS uses 18 and 21 gauge hypodermic needles with a 5 degree of freedom sensor located at the needle tip. These needles can only be sterilized using an ethylene oxide process. In the interest of providing clinicians with a simple and efficient guidance system, we also evaluated attaching the sensor at the needle hub as a simple clip-on device. To do this, we simultaneously performed a needle bending study to assess the reliability of a hub-based sensor.
引用
收藏
页数:8
相关论文
共 6 条
[1]   Needle Visualization in Ultrasound-Guided Regional Anesthesia: Challenges and Solutions [J].
Chin, Ki Ann ;
Perlas, Anahi ;
Chan, Vincent W. S. ;
Brull, Richard .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2008, 33 (06) :532-544
[2]  
Gobbi DG, 1999, LECT NOTES COMPUT SC, V1679, P920
[3]   Ultrasound-guided regional anesthesia - Current state of the art [J].
Gray, AT .
ANESTHESIOLOGY, 2006, 104 (02) :368-373
[4]   Ultrasound-Guided Regional Anesthesia and Analgesia A Qualitative Systematic Review [J].
Liu, Spencer S. ;
Ngeow, Justin E. ;
YaDeau, Jacques T. .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (01) :47-59
[5]  
Moore J, 2009, LECT NOTES COMPUT SC, V5761, P516, DOI 10.1007/978-3-642-04268-3_64
[6]   Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging [J].
Surry, KJM ;
Austin, HJB ;
Fenster, A ;
Peters, TM .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (24) :5529-5546