Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective

被引:37
作者
Fabry, Christian [1 ]
Langlois, Jean [2 ]
Hamadouche, Moussa [2 ]
Bader, Rainer [1 ]
机构
[1] Univ Med Rostock, Biomech & Implant Technol Res Lab, Dept Orthopaed, Doberaner Str 142, D-18057 Rostock, Germany
[2] Univ Paris 05, Hop Cochin, AP HP, Dept Orthopaed & Reconstruct Surg, 27 Rue Faubourg St Jacques, F-75014 Paris, France
关键词
Total hip arthroplasty; Wear; Dual mobility socket; Implant failure; Bousquet system; IPD; FOLLOW-UP; INTRAPROSTHETIC DISLOCATION; REPLACEMENT; SOCKET; STABILITY; REVISION; MOTION; HEAD; SYSTEM; RANGE;
D O I
10.1007/s00264-015-3000-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Recurrent dislocation of total hip arthroplasty is a frequent indication for revision surgery. Hip joint stability depends on implant design, cup position and crucially on femoral head diameter. Due to an effective ultra-large diameter femoral head, dual-mobility cups are considered an attractive solution to prevent dislocation in unstable conditions. Although patients obviously benefit for many years in terms of mobility and pain, an increase of intra-prosthetic dislocation reports using dual-mobility cups has been recently observed. However, the failure mechanism of this implant-specific complication, which is characterized by the loss of the positive-locking between the femoral head and the mobile liner, is not yet completely understood. Methods A comprehensive search was performed with the PubMed database and a search engine to overview this topic and to identify potential causes for this implant-specific failure from a clinical and biomechanical perspective. Results Peri-operative findings indicate extensive fibrosis at the large articulation as well as cup loosening as potential causes. In addition, current research has shown that the failure mechanism is affected by the surface topography of the femoral neck and in particular by the design of the mobile liner. Discussion In clinical practice it is necessary to differentiate a classic dislocation between the mobile liner and the metallic shell from an intra-prosthetic dislocation between the femoral head and the liner. Conclusion Due to the increasing popularity of dual-mobility cups in total hip arthroplasty, the understanding of which implant-specific features or tissue response may increase the risk of intra-prosthetic dislocation is of major importance for reduced revision rates by using optimized surgical techniques and implant designs.
引用
收藏
页码:901 / 906
页数:6
相关论文
共 36 条
[1]   Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies [J].
Abu-Amer, Yousef ;
Darwech, Isra ;
Clohisy, John C. .
ARTHRITIS RESEARCH & THERAPY, 2007, 9 (Suppl 1)
[2]  
[Anonymous], 2011, ANN REPORT
[3]   The influence of head and neck geometry on stability of total hip replacement - A mechanical test study [J].
Bader, R ;
Scholz, R ;
Steinhauser, E ;
Zimmermann, S ;
Busch, R ;
Mittelmeier, W .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (04) :415-421
[4]   Experimental analysis of standard, asymmetric and constraint liners for total hip replacement: Investigation of range of motion and stability against dislocation [J].
Bader, R ;
Steinhauser, E ;
Scholz, R ;
Simnacher, M ;
Mittelmeier, W .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2004, 142 (05) :577-585
[5]   Early Intraprosthetic Dislocation in a Revision Dual-mobility Hip Prosthesis [J].
Banka, Trevor R. ;
Ast, Michael P. ;
Parks, Michael L. .
ORTHOPEDICS, 2014, 37 (04) :E395-E397
[6]   Dislocation following total hip replacement: the Avon Orthopaedic Centre experience [J].
Blom, Ashley W. ;
Rogers, Mark ;
Taylor, Adrian H. ;
Pattison, Giles ;
Whitehouse, Sarah ;
Bannister, Gordon C. .
ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2008, 90 (08) :658-662
[7]   Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes - An in vitro study [J].
Burroughs, BR ;
Hallstrom, B ;
Golladay, GJ ;
Hoeffel, D ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :11-19
[8]   A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess wether a dual mobility cup has a decreased dislocation risk [J].
Caton, Jacques H. ;
Prudhon, Jean Louis ;
Ferreira, Andr ;
Aslanian, Thierry ;
Verdier, Regis .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (06) :1125-1129
[9]   Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis [J].
Chen, QS ;
Lazennec, JY ;
Guyen, O ;
Kinbrum, A ;
Berry, DJ ;
An, KN .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (06) :505-512
[10]   Low Rate of Dislocation of Dual-mobility Cups in Primary Total Hip Arthroplasty [J].
Combes, Antoine ;
Migaud, Henri ;
Girard, Julien ;
Duhamel, Alain ;
Fessy, Michel Henri .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (12) :3891-3900