Hematocrit and standardization in DBS analysis: A practical approach for hormones mainly present in the plasma fraction

被引:19
作者
Ackermans, Mariette T. [1 ]
de Kleijne, Vera [1 ]
Martens, Frans [1 ,2 ]
Heijboer, Annemieke C. [2 ]
机构
[1] Univ Amsterdam, Amsterdam UMC, Dept Clin Chem, Endocrine Lab, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Amsterdam UMC, Dept Clin Chem, Endocrine Lab, Amsterdam, Netherlands
关键词
DRIED BLOOD SPOTS; QUANTITATIVE-ANALYSIS; BIAS; QUANTIFICATION; BIOANALYSIS; PREDICTION; MATRIX;
D O I
10.1016/j.cca.2021.06.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background and aim: Dried blood spot (DBS) sampling has many advantages over conventionally used blood samples, but is thought to suffer from hematocrit related issues. The aim of our research was to investigate whether reliable results can be obtained without bothering about hematocrit effects in DBS analysis of analytes that are mainly present in the plasma compartment. Materials and Methods: Venous blood samples with variation in hematocrit and spotted volume were prepared. Spot diameter and 25-OH Vitamin D3 and testosterone concentrations were measured. Moreover, DBS and plasma concentrations of 25-OH Vitamin D3, testosterone and hematocrit were determined in random patient samples. Results: DBS spot size was linearly related to hematocrit. Measured DBS concentrations of 25-OH Vitamin D3 and testosterone were independent of hematocrit and spotted volume. Determining the relation between plasma and DBS concentration resulted in a factor that can be used to convert DBS concentrations to standardized plasma concentrations. Conclusion: Addressing the hematocrit issue is not necessary for hormones that are mainly present in the plasma compartment. The relation between plasma and DBS concentration can be used to convert DBS concentrations to standardized plasma concentrations which makes interpretation of DBS concentrations easier.
引用
收藏
页码:179 / 185
页数:7
相关论文
共 28 条
  • [1] Investigation of Different Approaches to Incorporating Internal Standard in DBS Quantitative Bioanalytical Workflows and Their Effect on Nullifying Hematocrit-Based Assay Bias
    Abu-Rabie, Paul
    Denniff, Philip
    Spooner, Neil
    Chowdhry, Babur Z.
    Pullen, Frank S.
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (09) : 4996 - 5003
  • [2] Determination of a steroid profile in heel prick blood using LC-MS/MS
    Boelen, Anita
    Ruiter, An F. C.
    Claahsen-van der Grinten, Hedi L.
    Endert, Erik
    Ackermans, Mariette T.
    [J]. BIOANALYSIS, 2016, 8 (05) : 375 - 384
  • [3] Comparison of eight routine unpublished LC-MS/MS methods for the simultaneous measurement of testosterone and androstenedione in serum
    Buttler, Rahel M.
    Martens, Frans
    Ackermans, Mariette T.
    Davison, Andrew S.
    van Herwaarden, Antonius E.
    Kortz, Linda
    Krabbe, Johannes G.
    Lentjes, Eef G. W.
    Syme, Charlotte
    Webster, Rachel
    Blankenstein, Marinus A.
    Heijboer, Annemieke C.
    [J]. CLINICA CHIMICA ACTA, 2016, 454 : 112 - 118
  • [4] Correction for the Hematocrit Bias in Dried Blood Spot Analysis Using a Nondestructive, Single-Wavelength Reflectance-Based Hematocrit Prediction Method
    Capiau, Sara
    Wilk, Leah S.
    De Kesel, Pieter M. M.
    Aalders, Maurice C. G.
    Stove, Christophe P.
    [J]. ANALYTICAL CHEMISTRY, 2018, 90 (03) : 1795 - 1804
  • [5] Prediction of the Hematocrit of Dried Blood Spots via Potassium Measurement on a Routine Clinical Chemistry Analyzer
    Capiau, Sara
    Stove, Veronique V.
    Lambert, Willy E.
    Stove, Christophe P.
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (01) : 404 - 410
  • [6] Potassium-based algorithm allows correction for the hematocrit bias in quantitative analysis of caffeine and its major metabolite in dried blood spots
    De Kesel, Pieter M. M.
    Capiau, Sara
    Stove, Veronique V.
    Lambert, Willy E.
    Stove, Christophe P.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (26) : 6749 - 6755
  • [7] De Kesel PM, 2013, BIOANALYSIS, V5, P2023, DOI [10.4155/BIO.13.156, 10.4155/bio.13.156]
  • [8] The effect of hematocrit on bioanalysis of DBS: results from the EBF DBS-microsampling consortium
    de Vries, Ronald
    Barfield, Matthew
    van de Merbel, Nico
    Schmid, Bernhard
    Siethoff, Christoph
    Ortiz, Jordi
    Verheij, Elwin
    van Baar, Ben
    Cobb, Zoe
    White, Steve
    Timmerman, Philip
    [J]. BIOANALYSIS, 2013, 5 (17) : 2147 - 2160
  • [9] Denniff P, 2010, BIOANALYSIS, V2, P1385, DOI [10.4155/bio.10.103, 10.4155/BIO.10.103]
  • [10] Evaluation of the Performance and Hematocrit Independence of the HemaPEN as a Volumetric Dried Blood Spot Collection Device
    Deprez, Sigrid
    Paniagua-Gonzalez, Lucia
    Velghe, Sofie
    Stove, Christophe P.
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (22) : 14467 - 14475