MPTS-silica coated capillary microextraction on line hyphenated with inductively coupled plasma atomic emission spectrometry for the determination of Cu, Hg and Pb in biological samples

被引:46
作者
Zheng, Fei [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
MPTS-silica coating; capillary microextraction; lCP-AES; cu; hg and ph; biological samples;
D O I
10.1016/j.talanta.2007.03.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel sol-gel 3-mercaptopropyltrimethoxysilane (MPTS) modified silica coating was developed for capillary microextraction (CME) of trace Cu, Hg and Pb prior to their on line determination by inductively coupled plasma-atomic emission spectrometry (ICP-AES). This organic-inorganic hybrid coating was in situ created on the inner walls of fused silica capillary using a sol solution containing TMOS (tetramethoxysilane) as a precursor, MPTS as a co-precursor, ethanol as the solvent and hydrochloric acid as a catalyst. The structure of the capillary coating was characterized by FF-IR spectroscopy, Raman spectroscopy, SEM and TEM. The factors affecting on the capillary microextraction of analytes such as pH, sample flow rate and volume, elution solution and interfering ions had been investigated, and the optimized experimental parameters were obtained. Under the optimized conditions, the absorption capacity of MPTS-silica coated capillary was found to be 1. 17, 1.96 and 1. 19 mu g m(-1) for Cu, Hg and Pb, and the limits of detection were as low as 0. 17 0.22 and 0.52 ng mL(-1), respectively. With a sampling frequency of 12 h(-1), the relative standard deviations (R.S.D.s) were 4.2, 2.6 and 3.8% (C=4 ng mL(-1), n = 7, sample volume = 1 mL) for Cu, Hg and Pb, respectively. The proposed method had been successfully applied to the determination of Cu, Hg and Pb in human urine, human serum and preserved egg. To validate the proposed method, certified reference materials of BCR151 milk powder, GBW07601 (GSH-1) human hair, GSBZ 50016-90 and GSB 07-1183-2000 water samples were analyzed and the determined values were in a good agreement with the certified values. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:372 / 379
页数:8
相关论文
共 29 条
[21]   Solid phase extraction vis-a-vis coprecipitation preconcentration of cadmium and lead from soils onto 5,7-dibromoquinoline-8-ol embedded benzophenone and determination by FAAS [J].
Prasad, K. ;
Gopikrishna, P. ;
Kala, R. ;
Rao, T. Prasada ;
Naidu, G. R. K. .
TALANTA, 2006, 69 (04) :938-945
[22]   γ-MPTMS modified nanometer-sized alumina micro-column separation and preconcentration of trace amounts of Hg, Cu, Au and Pd in biological, environmental and geological samples and their determination by inductively coupled plasma mass spectrometry [J].
Pu, XL ;
Jiang, ZC ;
Hu, B ;
Wang, HB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (08) :984-989
[23]   Use of flow injection cold vapour generation and preconcentration on silica functionalized with methylthiosalicylate for the determination of mercury in biological samples and sea-water by inductively coupled plasma atomic emission spectrometry [J].
Rudner, PC ;
Pavon, JMC ;
Rojas, FS ;
de Torres, AG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (10) :1167-1171
[24]   Direct filter vaporization with induction heating-electrothermal vaporization (IH-ETV) and a foam carbon surface [J].
Salin, ED ;
Ren, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (08) :953-954
[25]   Determination of lead in tap water by ICP-AES with flow-injection on-line adsorption preconcentration using a knotted reactor and ultrasonic nebulization [J].
Salonia, JA ;
Wuilloud, RG ;
Gásquez, JA ;
Olsina, RA ;
Martinez, LD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1239-1243
[26]   Rapid determination of bromide in seawater samples by capillary ion chromatography using monolithic silica columns modified with cetyltrimethylammonium ion [J].
Suzuki, Atsushi ;
Lim, Lee Wah ;
Hiroi, Toshiya ;
Takeuchi, Toyohide .
TALANTA, 2006, 70 (01) :190-193
[27]   Sol-gel column technology for single-step deactivation, coating, and stationary-phase immobilization in high-resolution capillary gas chromatography [J].
Wang, DX ;
Chong, SL ;
Malik, A .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4566-4576
[28]   Speciation of organoarsenic compounds by polypyrrole-coated capillary in-tube solid phase microextraction coupled with liquid chromatography/electrospray ionization mass spectrometry [J].
Wu, JC ;
Mester, Z ;
Pawliszyn, J .
ANALYTICA CHIMICA ACTA, 2000, 424 (02) :211-222
[29]   A pre-enrichment procedure using diethyldithiocarbamate-modified TiO2 nanoparticles for the analysis of biological and natural water samples by ICP-AES [J].
Zheng, H ;
Chang, X ;
Lian, N ;
Wang, S ;
Cui, Y ;
Zhai, Y .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2006, 86 (06) :431-441