MPTS-silica coated capillary microextraction on line hyphenated with inductively coupled plasma atomic emission spectrometry for the determination of Cu, Hg and Pb in biological samples

被引:46
作者
Zheng, Fei [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
MPTS-silica coating; capillary microextraction; lCP-AES; cu; hg and ph; biological samples;
D O I
10.1016/j.talanta.2007.03.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel sol-gel 3-mercaptopropyltrimethoxysilane (MPTS) modified silica coating was developed for capillary microextraction (CME) of trace Cu, Hg and Pb prior to their on line determination by inductively coupled plasma-atomic emission spectrometry (ICP-AES). This organic-inorganic hybrid coating was in situ created on the inner walls of fused silica capillary using a sol solution containing TMOS (tetramethoxysilane) as a precursor, MPTS as a co-precursor, ethanol as the solvent and hydrochloric acid as a catalyst. The structure of the capillary coating was characterized by FF-IR spectroscopy, Raman spectroscopy, SEM and TEM. The factors affecting on the capillary microextraction of analytes such as pH, sample flow rate and volume, elution solution and interfering ions had been investigated, and the optimized experimental parameters were obtained. Under the optimized conditions, the absorption capacity of MPTS-silica coated capillary was found to be 1. 17, 1.96 and 1. 19 mu g m(-1) for Cu, Hg and Pb, and the limits of detection were as low as 0. 17 0.22 and 0.52 ng mL(-1), respectively. With a sampling frequency of 12 h(-1), the relative standard deviations (R.S.D.s) were 4.2, 2.6 and 3.8% (C=4 ng mL(-1), n = 7, sample volume = 1 mL) for Cu, Hg and Pb, respectively. The proposed method had been successfully applied to the determination of Cu, Hg and Pb in human urine, human serum and preserved egg. To validate the proposed method, certified reference materials of BCR151 milk powder, GBW07601 (GSH-1) human hair, GSBZ 50016-90 and GSB 07-1183-2000 water samples were analyzed and the determined values were in a good agreement with the certified values. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:372 / 379
页数:8
相关论文
共 29 条
[11]   Separation and determination of L-tyrosine and its metabolites by capillary zone electrophoresis with a wall-jet amperometric detection [J].
Huang, Ying ;
Jiang, Xiuyan ;
Wang, Wei ;
Duan, Jianping ;
Chen, Guonan .
TALANTA, 2006, 70 (05) :1157-1163
[12]   Determination of Ti, V, Zr, Nb, Mo and Ta in high-purity iron using cupferron co-precipitation separation by axially viewed ICP-AES with ultrasonic nebulization system and a long torch [J].
Ide, K ;
Nakamura, Y .
MATERIALS TRANSACTIONS, 2002, 43 (06) :1409-1414
[13]   Determination of trace elements in pumpkin seed oils and pumpkin seeds by ICP-AES [J].
Juranovic, I ;
Breinhoelder, P ;
Steffan, I .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (01) :54-58
[14]   Parts per quadrillion level ultra-trace determination of polar and nonpolar compounds via solvent-free capillary microextraction on surface-bonded sol-gel polytetrahydrofuran coating and gas chromatography-flame ionization detection [J].
Kabir, A ;
Hamlet, C ;
Malik, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1047 (01) :1-13
[15]   Automated in tube solid-phase microextraction coupled with liquid chromatography/electrospray ionization mass spectrometry for the determination of β-blockers and metabolites in urine and serum samples [J].
Kataoka', H ;
Narimatsu, S ;
Lord, HL ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4237-4244
[16]   High pH-resistant, surface-bonded sol-gel titania hybrid organic-inorganic coating for effective on-line hyphenation of capillary microextraction (in-tube solid-phase microextraction) with high-performance liquid chromatography [J].
Kim, TY ;
Alhooshani, K ;
Kabir, A ;
Fries, DP ;
Malik, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1047 (02) :165-174
[17]   A review on solid phase microextraction - High performance liquid chromatography as a novel tool for the analysis of toxic metal ions [J].
Malik, AK ;
Kaur, V ;
Verma, N .
TALANTA, 2006, 68 (03) :842-849
[18]  
Mester Z, 1999, RAPID COMMUN MASS SP, V13, P1999, DOI 10.1002/(SICI)1097-0231(19991030)13:20<1999::AID-RCM744>3.3.CO
[19]  
2-3
[20]   New preservation method for inorganic arsenic speciation in acid mine drainage samples [J].
Oliveira, V. ;
Sarmiento, A. M. ;
Gomez-Ariza, J. L. ;
Nieto, J. M. ;
Sanchez-Rodas, D. .
TALANTA, 2006, 69 (05) :1182-1189