MPTS-silica coated capillary microextraction on line hyphenated with inductively coupled plasma atomic emission spectrometry for the determination of Cu, Hg and Pb in biological samples

被引:46
作者
Zheng, Fei [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
MPTS-silica coating; capillary microextraction; lCP-AES; cu; hg and ph; biological samples;
D O I
10.1016/j.talanta.2007.03.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel sol-gel 3-mercaptopropyltrimethoxysilane (MPTS) modified silica coating was developed for capillary microextraction (CME) of trace Cu, Hg and Pb prior to their on line determination by inductively coupled plasma-atomic emission spectrometry (ICP-AES). This organic-inorganic hybrid coating was in situ created on the inner walls of fused silica capillary using a sol solution containing TMOS (tetramethoxysilane) as a precursor, MPTS as a co-precursor, ethanol as the solvent and hydrochloric acid as a catalyst. The structure of the capillary coating was characterized by FF-IR spectroscopy, Raman spectroscopy, SEM and TEM. The factors affecting on the capillary microextraction of analytes such as pH, sample flow rate and volume, elution solution and interfering ions had been investigated, and the optimized experimental parameters were obtained. Under the optimized conditions, the absorption capacity of MPTS-silica coated capillary was found to be 1. 17, 1.96 and 1. 19 mu g m(-1) for Cu, Hg and Pb, and the limits of detection were as low as 0. 17 0.22 and 0.52 ng mL(-1), respectively. With a sampling frequency of 12 h(-1), the relative standard deviations (R.S.D.s) were 4.2, 2.6 and 3.8% (C=4 ng mL(-1), n = 7, sample volume = 1 mL) for Cu, Hg and Pb, respectively. The proposed method had been successfully applied to the determination of Cu, Hg and Pb in human urine, human serum and preserved egg. To validate the proposed method, certified reference materials of BCR151 milk powder, GBW07601 (GSH-1) human hair, GSBZ 50016-90 and GSB 07-1183-2000 water samples were analyzed and the determined values were in a good agreement with the certified values. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:372 / 379
页数:8
相关论文
共 29 条
[1]   Sorption of arsenic, bismuth, mercury, antimony, selenium and tin on dithiocarbamate loaded polyurethane foam as a preconcentration method for their determination in water samples by simultaneous inductively coupled plasma atomic emission spectrometry and electrothermal atomic absorption spectrometry [J].
Arpadjan, S ;
Vuchkova, L ;
Kostadinova, E .
ANALYST, 1997, 122 (03) :243-246
[2]   Direct analysis of beer by ICP-AES: A very simple method for the determination of Cu, Mn and Fe [J].
Asfaw, A ;
Wibetoe, G .
MICROCHIMICA ACTA, 2005, 152 (1-2) :61-68
[3]   Sol-gel capillary microextraction [J].
Bigham, S ;
Medlar, J ;
Kabir, A ;
Shende, C ;
Alli, A ;
Malik, A .
ANALYTICAL CHEMISTRY, 2002, 74 (04) :752-761
[4]  
Chen JJ, 2004, J FOOD DRUG ANAL, V12, P332
[5]   ICP-AES determination of trace elements after preconcentrated with p-dimethylaminobenzaldehyde-modified nanometer SiO2 from sample solution [J].
Cui, Yuemei ;
Chang, Xijun ;
Zhai, Yiinhui ;
Zhu, Xiangbing ;
Zheng, Hong ;
Lian, Ning .
MICROCHEMICAL JOURNAL, 2006, 83 (01) :35-41
[6]   A low-powered microwave thermospray nebulizer for inductively coupled plasma atomic emission spectrometry [J].
Ding, L ;
Liang, F ;
Huan, YF ;
Cao, YB ;
Zhang, HQ ;
Jin, QH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (03) :293-296
[7]   Poly (methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary for in-tube solid phase microextraction coupled to high performance liquid chromatography and its application to determination of basic drugs in human serum [J].
Fan, Y ;
Feng, YQ ;
Da, SL ;
Shi, ZG .
ANALYTICA CHIMICA ACTA, 2004, 523 (02) :251-258
[8]   Rapid determination of mercury in plant and soil samples using inductively coupled plasma atomic emission spectroscopy, a comparative study [J].
Han, FXX ;
Patterson, WD ;
Xia, YJ ;
Sridhar, BB ;
Su, Y .
WATER AIR AND SOIL POLLUTION, 2006, 170 (1-4) :161-171
[9]   Fluorous ionic liquids as solvents for the liquid-liquid extraction of metal ions by macrocyclic polyethers [J].
Heitzman, H ;
Young, BA ;
Rausch, DJ ;
Rickert, P ;
Stepinski, DC ;
Dietz, ML .
TALANTA, 2006, 69 (02) :527-531
[10]   The application of chemical modification in electrothermal vaporization-inductively coupled plasma atomic emission spectrometry [J].
Hu, B ;
Jiang, ZC ;
Peng, TY ;
Qin, YC .
TALANTA, 1999, 49 (02) :357-365