Reproducibility and repeatability of same-day two sequential FDG PET/MR and PET/CT

被引:12
作者
Groshar, David [1 ,2 ]
Bernstine, Hanna [1 ,2 ]
Goldberg, Natalia [1 ]
Nidam, Meital [1 ]
Stein, Dan [1 ]
Abadi-Korek, Ifat [1 ]
Domachevsky, Liran [1 ]
机构
[1] Assuta Med Ctr, Dept Nucl Med, 20 Habarzel St, IL-6971028 Tel Aviv, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
来源
CANCER IMAGING | 2017年 / 17卷
关键词
PET/MR; SUV; Reproducibility; Repeatability; Reliability; CELL LUNG-CANCER; CLINICAL-EXPERIENCE; VOLUME MEASUREMENTS; LESION DETECTION; F-18-FDG PET/MR; QUANTIFICATION; QUANTITATION; PERFORMANCE; MULTICENTER;
D O I
10.1186/s40644-017-0113-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To determine PET/CT and PET/MR reproducibility and PET/MR repeatability of fluorine 18 fluorodeoxyglucose (FDG) uptake measurements in tumors in cancer patients. Methods: This IRB approved prospective study was performed between October 2015 and February 2016 in consecutive patients who performed same day PET/CT and two sequential PET/MR. Thirty three patients with visible tumors (N=63) were included. SUV for body weight (SUV) and lean body mass (SUL) were obtained. Volume of interest (VOI) with a threshold of 40% was used and SUV/L's, metabolic tumor volume (MTV) and tumor to liver ratio (T/L) were calculated. Measurements were plotted in a scattered diagram to visually identify correlation, a regression line was drawn and the equation of the line was calculated. Bland-Altman plots expressed as percentages were constructed to assess the agreement between measurements. The maximal clinically acceptable limits range was defined as +/- 30%. Results: Lesional SUV's, SUL's and MTV corrected to body weight (BW) and lean body mass (LBM) demonstrated strong positive linear correlation between PET/CT and PET/MR and between two sequential PET/MR. The 95% limits of agreement ranged from -27.7 to 17.5 with a mean of -5.1 and -27.6 to 17.9 with a mean of -4.9 for SUVpeak and SULpeak, respectively for sequential PET/MR. Other PET metrics demonstrated limits range that is above +/- 30% between PET/CT and PET/MR and between two sequential PET/MR. Conclusion: PET/MR SUV/L peak has a clinically acceptable repeatability performance and can be used to evaluate the response to treatment.
引用
收藏
页数:9
相关论文
共 20 条
[1]   Qualitative and Quantitative Comparison of PET/CT and PET/MR Imaging in Clinical Practice [J].
Al-Nabhani, Khalsa Z. ;
Syed, Rizwan ;
Michopoulou, Sofia ;
Alkalbani, Jokha ;
Afaq, Asim ;
Panagiotidis, Emmanouil ;
O'Meara, Celia ;
Groves, Ashley ;
Ell, Peter ;
Bomanji, Jamshed .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (01) :88-94
[2]   Staging and response assessment in lymphomas: the new Lugano classification [J].
Cheson, Bruce D. .
CHINESE CLINICAL ONCOLOGY, 2015, 4 (01)
[3]   Repeatability of 18F-FDG Uptake Measurements in Tumors: A Metaanalysis [J].
de Langen, Adrianus J. ;
Vincent, Andrew ;
Velasquez, Linda M. ;
van Tinteren, Harm ;
Boellaard, Ronald ;
Shankar, Lalitha K. ;
Boers, Maarten ;
Smit, Egbert F. ;
Stroobants, Sigrid ;
Weber, Wolfgang A. ;
Hoekstra, Otto S. .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (05) :701-708
[4]   Survival Prognostic Value of Morphological and Metabolic variables in Patients with Stage I and II Non-Small Cell Lung Cancer [J].
Domachevsky, L. ;
Groshar, D. ;
Galili, R. ;
Saute, M. ;
Bernstine, H. .
EUROPEAN RADIOLOGY, 2015, 25 (11) :3361-3367
[5]   First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses [J].
Drzezga, Alexander ;
Souvatzoglou, Michael ;
Eiber, Matthias ;
Beer, Ambros J. ;
Fuerst, Sebastian ;
Martinez-Moeller, Axel ;
Nekolla, Stephan G. ;
Ziegler, Sibylle ;
Ganter, Carl ;
Rummeny, Ernst J. ;
Schwaiger, Markus .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) :845-855
[6]   Performance of Whole-Body Integrated 18F-FDG PET/MR in Comparison to PET/CT for Evaluation of Malignant Bone Lesions [J].
Eiber, Matthias ;
Takei, Toshiki ;
Souvatzoglou, Michael ;
Mayerhoefer, Marius E. ;
Fuerst, Sebastian ;
Gaertner, Florian C. ;
Loeffelbein, Denys J. ;
Rummeny, Ernst J. ;
Ziegler, Sibylle I. ;
Schwaiger, Markus ;
Beer, Ambros J. .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (02) :191-197
[7]   Repeatability of Metabolically Active Tumor Volume Measurements with FDG PET/CT in Advanced Gastrointestinal Malignancies: A Multicenter Study [J].
Frings, Virginie ;
van Velden, Floris H. P. ;
Velasquez, Linda M. ;
Hayes, Wendy ;
van de Ven, Peter M. ;
Hoekstra, Otto S. ;
Boellaard, Ronald .
RADIOLOGY, 2014, 273 (02) :539-548
[8]   Repeatability of Metabolically Active Volume Measurements with 18F-FDG and 18F-FLT PET in Non-Small Cell Lung Cancer [J].
Frings, Virginie ;
de Langen, Adrianus J. ;
Smit, Egbert F. ;
van Velden, Floris H. P. ;
Hoekstra, Otto S. ;
van Tinteren, Harm ;
Boellaard, Ronald .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (12) :1870-1877
[9]   Quantitative comparison of PET performance-Siemens Biograph mCT and mMR [J].
Karlberg, Anna M. ;
Saether, Oddbjorn ;
Eikenes, Live ;
Goa, Pal Erik .
EJNMMI PHYSICS, 2016, 3 (01)
[10]  
Li X, 2016, EUR J NUCL MED MOL I, V43, P1503, DOI 10.1007/s00259-016-3308-6