Reproducibility and repeatability of same-day two sequential FDG PET/MR and PET/CT

被引:12
作者
Groshar, David [1 ,2 ]
Bernstine, Hanna [1 ,2 ]
Goldberg, Natalia [1 ]
Nidam, Meital [1 ]
Stein, Dan [1 ]
Abadi-Korek, Ifat [1 ]
Domachevsky, Liran [1 ]
机构
[1] Assuta Med Ctr, Dept Nucl Med, 20 Habarzel St, IL-6971028 Tel Aviv, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
来源
CANCER IMAGING | 2017年 / 17卷
关键词
PET/MR; SUV; Reproducibility; Repeatability; Reliability; CELL LUNG-CANCER; CLINICAL-EXPERIENCE; VOLUME MEASUREMENTS; LESION DETECTION; F-18-FDG PET/MR; QUANTIFICATION; QUANTITATION; PERFORMANCE; MULTICENTER;
D O I
10.1186/s40644-017-0113-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To determine PET/CT and PET/MR reproducibility and PET/MR repeatability of fluorine 18 fluorodeoxyglucose (FDG) uptake measurements in tumors in cancer patients. Methods: This IRB approved prospective study was performed between October 2015 and February 2016 in consecutive patients who performed same day PET/CT and two sequential PET/MR. Thirty three patients with visible tumors (N=63) were included. SUV for body weight (SUV) and lean body mass (SUL) were obtained. Volume of interest (VOI) with a threshold of 40% was used and SUV/L's, metabolic tumor volume (MTV) and tumor to liver ratio (T/L) were calculated. Measurements were plotted in a scattered diagram to visually identify correlation, a regression line was drawn and the equation of the line was calculated. Bland-Altman plots expressed as percentages were constructed to assess the agreement between measurements. The maximal clinically acceptable limits range was defined as +/- 30%. Results: Lesional SUV's, SUL's and MTV corrected to body weight (BW) and lean body mass (LBM) demonstrated strong positive linear correlation between PET/CT and PET/MR and between two sequential PET/MR. The 95% limits of agreement ranged from -27.7 to 17.5 with a mean of -5.1 and -27.6 to 17.9 with a mean of -4.9 for SUVpeak and SULpeak, respectively for sequential PET/MR. Other PET metrics demonstrated limits range that is above +/- 30% between PET/CT and PET/MR and between two sequential PET/MR. Conclusion: PET/MR SUV/L peak has a clinically acceptable repeatability performance and can be used to evaluate the response to treatment.
引用
收藏
页数:9
相关论文
共 20 条
  • [1] Qualitative and Quantitative Comparison of PET/CT and PET/MR Imaging in Clinical Practice
    Al-Nabhani, Khalsa Z.
    Syed, Rizwan
    Michopoulou, Sofia
    Alkalbani, Jokha
    Afaq, Asim
    Panagiotidis, Emmanouil
    O'Meara, Celia
    Groves, Ashley
    Ell, Peter
    Bomanji, Jamshed
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (01) : 88 - 94
  • [2] Staging and response assessment in lymphomas: the new Lugano classification
    Cheson, Bruce D.
    [J]. CHINESE CLINICAL ONCOLOGY, 2015, 4 (01)
  • [3] Repeatability of 18F-FDG Uptake Measurements in Tumors: A Metaanalysis
    de Langen, Adrianus J.
    Vincent, Andrew
    Velasquez, Linda M.
    van Tinteren, Harm
    Boellaard, Ronald
    Shankar, Lalitha K.
    Boers, Maarten
    Smit, Egbert F.
    Stroobants, Sigrid
    Weber, Wolfgang A.
    Hoekstra, Otto S.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (05) : 701 - 708
  • [4] Survival Prognostic Value of Morphological and Metabolic variables in Patients with Stage I and II Non-Small Cell Lung Cancer
    Domachevsky, L.
    Groshar, D.
    Galili, R.
    Saute, M.
    Bernstine, H.
    [J]. EUROPEAN RADIOLOGY, 2015, 25 (11) : 3361 - 3367
  • [5] First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses
    Drzezga, Alexander
    Souvatzoglou, Michael
    Eiber, Matthias
    Beer, Ambros J.
    Fuerst, Sebastian
    Martinez-Moeller, Axel
    Nekolla, Stephan G.
    Ziegler, Sibylle
    Ganter, Carl
    Rummeny, Ernst J.
    Schwaiger, Markus
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) : 845 - 855
  • [6] Performance of Whole-Body Integrated 18F-FDG PET/MR in Comparison to PET/CT for Evaluation of Malignant Bone Lesions
    Eiber, Matthias
    Takei, Toshiki
    Souvatzoglou, Michael
    Mayerhoefer, Marius E.
    Fuerst, Sebastian
    Gaertner, Florian C.
    Loeffelbein, Denys J.
    Rummeny, Ernst J.
    Ziegler, Sibylle I.
    Schwaiger, Markus
    Beer, Ambros J.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (02) : 191 - 197
  • [7] Repeatability of Metabolically Active Tumor Volume Measurements with FDG PET/CT in Advanced Gastrointestinal Malignancies: A Multicenter Study
    Frings, Virginie
    van Velden, Floris H. P.
    Velasquez, Linda M.
    Hayes, Wendy
    van de Ven, Peter M.
    Hoekstra, Otto S.
    Boellaard, Ronald
    [J]. RADIOLOGY, 2014, 273 (02) : 539 - 548
  • [8] Repeatability of Metabolically Active Volume Measurements with 18F-FDG and 18F-FLT PET in Non-Small Cell Lung Cancer
    Frings, Virginie
    de Langen, Adrianus J.
    Smit, Egbert F.
    van Velden, Floris H. P.
    Hoekstra, Otto S.
    van Tinteren, Harm
    Boellaard, Ronald
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (12) : 1870 - 1877
  • [9] Quantitative comparison of PET performance-Siemens Biograph mCT and mMR
    Karlberg, Anna M.
    Saether, Oddbjorn
    Eikenes, Live
    Goa, Pal Erik
    [J]. EJNMMI PHYSICS, 2016, 3 (01):
  • [10] Quantitative assessment of atherosclerotic plaques on 18F-FDG PET/MRI: comparison with a PET/CT hybrid system
    Li, Xiang
    Heber, Daniel
    Rausch, Ivo
    Beitzke, Dietrich
    Mayerhoefer, Marius E.
    Rasul, Sazan
    Kreissl, Michael
    Mitthauser, Markus
    Wadsak, Wolfgang
    Hartenbach, Markus
    Haug, Alexander
    Zhang, Xiaoli
    Loewe, Christian
    Beyer, Thomas
    Hacker, Marcus
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (08) : 1503 - 1512