Treatment of a traumatic carotid-cavernous fistula by the sole use of a flow diverting stent

被引:35
作者
Nadarajah, Mahendran [1 ]
Power, Mark [2 ]
Barry, Bryan [3 ]
Wenderoth, Jason [1 ]
机构
[1] Prince Wales Hosp, INR, Sydney, NSW, Australia
[2] Liverpool Hosp, Dept Radiol, Liverpool, NSW, Australia
[3] Prince Wales Hosp, Dept Med, Sydney, NSW, Australia
关键词
PIPELINE EMBOLIZATION DEVICE; DURAL ARTERIOVENOUS-FISTULAS; PARENT ARTERY-OCCLUSION; OF-THE-LITERATURE; SINUS FISTULA; TRANSVENOUS EMBOLIZATION; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; COVERED STENT; RECONSTRUCTION;
D O I
10.1136/neurintsurg-2011-010000
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Direct caroticocavernous fistula (CCF) has traditionally been treated by detachable balloon placement within the affected cavernous sinus. We describe a case of a direct CCF treated solely with flow-diverting stents. These novel devices may offer a simpler and potentially safer vessel-sparing option in this rare condition.
引用
收藏
页数:4
相关论文
共 41 条
[1]   Infectious Aneurysm of the Cavernous Carotid Artery in a Child Treated With a New-Generation of Flow-Diverting Stent Graft: Case Report [J].
Appelboom, Geoffrey ;
Kadri, Khaled ;
Hassan, Farouk ;
Leclerc, Xavier .
NEUROSURGERY, 2010, 66 (03) :E623-U214
[2]  
Biondi A, 2003, AM J NEURORADIOL, V24, P1240
[3]   The treatment of carotid cavernous arteriovenous aneurysm [J].
Dandy, WE .
ANNALS OF SURGERY, 1935, 102 :916-926
[4]   TREATMENT OF 54 TRAUMATIC CAROTID-CAVERNOUS FISTULAS [J].
DEBRUN, G ;
LACOUR, P ;
VINUELA, F ;
FOX, A ;
DRAKE, CG ;
CARON, JP .
JOURNAL OF NEUROSURGERY, 1981, 55 (05) :678-692
[5]   DETACHABLE BALLOON AND CALIBRATED-LEAK BALLOON TECHNIQUES IN TREATMENT OF CEREBRAL VASCULAR-LESIONS [J].
DEBRUN, G ;
LACOUR, P ;
CARON, JP ;
HURTH, M ;
COMOY, J ;
KERAVEL, Y .
JOURNAL OF NEUROSURGERY, 1978, 49 (05) :635-649
[6]   Traumatic carotid-cavernous fistula: Pathophysiology and treatment [J].
Fattahi, TT ;
Brandt, MT ;
Jenkins, WS ;
Steinberg, B .
JOURNAL OF CRANIOFACIAL SURGERY, 2003, 14 (02) :240-246
[7]   Treatment of extracranial and intracranial aneurysms and arteriovenous fistulae using stent grafts [J].
Felber, S ;
Henkes, H ;
Weber, W ;
Miloslavski, E ;
Brew, S ;
Kühne, D .
NEUROSURGERY, 2004, 55 (03) :631-638
[8]   Reconstruction of the right anterior circulation with the Pipeline embolization device to achieve treatment of a progressively symptomatic, large carotid aneurysm [J].
Fiorella, D. ;
Albuquerque, F. ;
Gonzalez, F. ;
McDougall, C. G. ;
Nelson, P. K. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2010, 2 (01) :31-37
[9]   Definitive reconstruction of circumferential fusiform intracranial aneurysms with the pipeline embolization device [J].
Fiorella, David ;
Woo, Henry H. ;
Albuquerque, Felipe C. ;
Nelson, Peter K. .
NEUROSURGERY, 2008, 62 (05) :1115-1120
[10]   CURATIVE RECONSTRUCTION OF A GIANT MIDBASILAR TRUNK ANEURYSM WITH THE PIPELINE EMBOLIZATION DEVICE [J].
Fiorella, David ;
Kelly, Michael E. ;
Albuquerque, Felipe C. ;
Nelson, Peter K. .
NEUROSURGERY, 2009, 64 (02) :212-217