Separation and Quantification of 1,4-benzodiazepines: HPLC versus CZE

被引:4
作者
Kalikova, Kveta [1 ]
Riesova, Martina [1 ]
Chudoba, Richard [1 ]
Schmid, Martin G. [2 ]
Tesarova, Eva [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Dept Phys & Macromol Chem, Prague 12843 2, Czech Republic
[2] Karl Franzens Univ Graz, Inst Pharmaceut Sci, Dept Pharmaceut Chem, A-8010 Graz, Austria
关键词
RP-HPLC; CZE; benzodiazepines; pharmaceuticals; CAPILLARY-ZONE-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; BACKGROUND ELECTROLYTES; MASS-SPECTROMETRY; BIOLOGICAL-FLUIDS; BENZODIAZEPINES; PHARMACEUTICALS; PLASMA; SERUM; METABOLITES;
D O I
10.5562/cca1738
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The goal of the present study was to separate a set of benzodiazepines, namely bromazepam, oxazepam, nitrazepam, chlordiazepoxide, flunitrazepam, lormetazepam and diazepam by analytical scale HPLC and CZE. The both methods for separation of these seven compounds from the 1,4-benzodiazepine group were optimized and compared. LODs and LOQs were determined under the optimized conditions in the both methods. The corresponding LOD and LOQ values are approximately three orders of magnitude lower in HPLC than in CZE. As expected, elution order was found to be different for the both techniques. As a result of a critical collation of all the parameters considered, RP-HPLC was found to be more suitable for determination of the set of benzodiazepines. A real sample analysis was performed under optimized conditions to demonstrate applicability of the proposed analytical methods. (doi: 10.5562/cca1738)
引用
收藏
页码:367 / 373
页数:7
相关论文
共 26 条
[1]   Why robust background electrolytes containing multivalent ionic species can fail in capillary zone electrophoresis [J].
Beckers, JL ;
Gebauer, P ;
Bocek, P .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :41-49
[2]   BIOPHARMACOLOGICAL DATA AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF 1,4-BENZODIAZEPINES IN BIOLOGICAL-FLUIDS - A REVIEW [J].
BERRUETA, LA ;
GALLO, B ;
VICENTE, F .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (2-3) :109-136
[3]   IMMUNOLOGICAL DETERMINATION OF BENZODIAZEPINES - INFLUENCE OF MOLECULAR-STRUCTURES ON THE CROSS-REACTIVITY [J].
BEYER, KH ;
MARTZ, S .
ARCHIV DER PHARMAZIE, 1991, 324 (11) :933-935
[4]   Methods for the measurement of benzodiazepines in biological samples [J].
Drummer, OH .
JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (01) :201-225
[5]   High-performance liquid chromatographic method for the determination of benzodiazepines in plasma or serum using the column-switching technique [J].
El Mahjoub, A ;
Staub, C .
JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (02) :381-390
[6]   DETERMINATION OF 1,4-BENZODIAZEPINES IN DRUG-DOSAGE FORMS BY DIFFERENCE SPECTROPHOTOMETRY [J].
ELBRASHY, A ;
ALY, FA ;
BELAL, F .
MIKROCHIMICA ACTA, 1993, 110 (1-3) :55-60
[7]  
Es'haghi Z, 2009, CHEMIJA, V20, P180
[8]  
Gas B, 2005, LC GC EUR, V18, P282
[9]   System zones in capillary zone electrophoresis [J].
Gas, B ;
Kenndler, E .
ELECTROPHORESIS, 2004, 25 (23-24) :3901-3912
[10]   Prediction and understanding system peaks in capillary zone electrophoresis [J].
Gas, Bohuslav ;
Hruska, Vlastimil ;
Dittmann, Monika ;
Bek, Fritz ;
Witt, Klaus .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (10) :1435-1445