摘要
An optimized single-channel phoswich well detector design has been proposed and assessed in order to improve beta-gamma coincidence measurement sensitivity of xenon radioisotopes. This newly designed phoswich well detector consists of a plastic beta counting cell (BC404) embedded in a CsI(Tl) crystal coupled to a photomultiplier tube. The BC404 is configured in a cylindrical pipe shape to minimise light collection deterioration. The CsI(Tl) crystal consists of a rectangular part and a semicylindrical scintillation part as a light reflector to increase light gathering. Compared with a PhosWatch detector, the final optimized detector geometry showed 15% improvement in the energy resolution of a Xe-131m 129.4 keV conversion electron peak. The predicted betagamma coincidence efficiencies of xenon radioisotopes have also been improved accordingly.
引用
收藏
页数:5
相关论文
共 10 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Single-channel beta-gamma coincidence detection of radioactive xenon using digital pulse shape analysis of phoswich detector signals [J].
Hennig, W ;
Tan, H ;
Warburton, WK ;
McIntyre, JI .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (02) :620-624
[3]  
Hennig W., 2008, MONITORING RES REV G
[4]  
Innocente V., 2003, CERN VERSION1 0
[5]   Monte Carlo simulation of a PhosWatch detector using Geant4 for xenon isotope beta-gamma coincidence spectrum profile and detection efficiency calculations [J].
Mekarski, P. ;
Zhang, W. ;
Ungar, K. ;
Bean, M. ;
Korpach, E. .
APPLIED RADIATION AND ISOTOPES, 2009, 67 (10) :1957-1963
[6]  
Popov Y. S., 2000, CTBTOSIWS6PR15
[7]   Beta-gamma counting system for Xe fission products [J].
Reeder, PL ;
Bowyer, TW ;
Perkins, RW .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 235 (1-2) :89-94
[8]   SAUNA - a system for automatic sampling, processing, and analysis of radioactive xenon [J].
Ringbom, A ;
Larson, T ;
Axelsson, A ;
Elmgren, K ;
Johansson, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 508 (03) :542-553
[9]   Notes on radioxenon measurements for CTBT verification purposes [J].
Saey, PRJ ;
De Geer, LE .
APPLIED RADIATION AND ISOTOPES, 2005, 63 (5-6) :765-773
[10]  
Zhang W., 2010, APPL RAD ISOTOPES