Structural performance of rotationally restrained steel columns in fire

被引:98
|
作者
Ali, F [1 ]
O'Connor, D [1 ]
机构
[1] Univ Ulster, Ctr Fire Res, Jordanstown BT37 0QB, Antrim, North Ireland
关键词
steel columns; steel frames; fire; rotational restraint; effective length;
D O I
10.1016/S0379-7112(01)00017-0
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper represents the outcomes of a parametric experimental investigation on the performance of rotationally restrained steel columns in fire. This experimental programme is a part of major research project performed at the Fire Research Center, University of Ulster in collaboration with the University of Sheffield. As a part of steel frames, half scale steel columns were tested in fire under two values of rotational restraint 0.18 and 0.93 and one value of axial restraint of approximately 0.29. Each case of rotational restraint was tested under five loading levels 0, 0.2, 0.4, 0.6 and 0.8. The paper includes a comparison with the behavior of a steel column previously tested in fire under axial restraint only. The paper represents also a method of estimating the effective length of fixed end (partial fixity) columns tested under fire. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:679 / 691
页数:13
相关论文
共 50 条
  • [1] Structural fire performance of axially and rotationally restrained stainless steel columns
    Pournaghshband, A.
    Afshan, S.
    Foster, A. S. J.
    THIN-WALLED STRUCTURES, 2019, 137 (561-572) : 561 - 572
  • [2] Dynamic performance of axially and rotationally restrained steel columns under fire
    Jiang, Binhui
    Li, Guo-Qiang
    Izzuddin, B. A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 : 308 - 315
  • [3] Fire performance of restrained welded steel box columns
    Yang, Kuo Chen
    Yang, Fang Chieh
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 107 : 173 - 181
  • [4] Thermal buckling of rotationally restrained steel columns
    Cai, Jianguo
    Feng, Jian
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (06) : 835 - 841
  • [5] Fire performance of axially restrained steel reinforced concrete columns
    Zheng C.
    Wang G.
    Li Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (08): : 154 - 161
  • [6] The behaviour of rotationally restrained concrete filled tubular columns in fire
    School of Mechanical, Aerospace and Civil Engineering , University of Manchester, PO Box 88, Manchester, M60 1QD, United Kingdom
    Weld. World, SPEC. ISS. (379-385):
  • [7] Coupled Structural-thermal Calculations for Restrained Steel Columns in Fire
    Kwasniewski, Laslaw
    Ali, Faris
    Balcerzak, Marcin
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2013, 4 (01) : 59 - 70
  • [8] The performance in fire of restrained steel columns in multi-storey construction
    Shepherd, PG
    Burgess, IW
    Plank, RJ
    O'Connor, DJ
    STRUCTURES IN THE NEW MILLENNIUM, 1997, : 333 - 340
  • [9] On the buckling of axially restrained steel columns in fire
    Shepherd, P. G.
    Burgess, I. W.
    ENGINEERING STRUCTURES, 2011, 33 (10) : 2832 - 2838
  • [10] Buckling of restrained steel columns due to fire conditions
    Hozjan, Tomaz
    Planinc, Igor
    Saje, Miran
    Srpcic, Stanislav
    STEEL AND COMPOSITE STRUCTURES, 2008, 8 (02): : 159 - 178