In silico comparison of the reproducibility of full-arch implant provisional restorations to final restoration between a 3D Scan/CAD/CAM technique and the conventional method

被引:16
作者
Mino, Takuya [1 ]
Maekawa, Kenji [2 ]
Ueda, Akihiro [2 ]
Higuchi, Shizuo [3 ]
Sejima, Junichi [2 ]
Takeuchi, Tetsuo [2 ]
Hara, Emilio Satoshi [1 ]
Kimura-Ono, Aya [1 ]
Sonoyama, Wataru [1 ]
Kuboki, Takuo [1 ]
机构
[1] Okayama Univ, Dept Oral Rehabil & Regenerat Med, Grad Sch Med Dent & Pharmaceut Sci, Okayama 7008525, Japan
[2] Okayama Univ Hosp, Hosp Med Technol Part, Dent Labs, Okayama, Japan
[3] Wada Precis Dent Labs, Tokyo, Japan
基金
日本学术振兴会;
关键词
Accurate transfer; Implant final restoration; In silico analysis; Provisional restoration; Scan/CAD/CAM technique; CAST;
D O I
10.1016/j.jpor.2014.12.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this article was to investigate the accuracy in the reproducibility of full-arch implant provisional restorations to final restorations between a 3D Scan/CAD/CAM technique and the conventional method. Methods: We fabricated two final restorations for rehabilitation of maxillary and mandibular complete edentulous area and performed a computer-based comparative analysis of the accuracy in the reproducibility of the provisional restoration to final restoration between a 3D scanning and CAD/CAM (Scan/CAD/CAM) technique and the conventional silicone-mold transfer technique. Final restorations fabricated either by the conventional or Scan/CAD/CAM method were successfully installed in the patient. The total concave/convex volume discrepancy observed with the Scan/CAD/CAM technique was 503.50 mm(3) and 338.15 mm(3) for maxillary and mandibular implant-supported prostheses (ISPs), respectively. On the other hand, total concave/convex volume discrepancy observed with the conventional method was markedly high (1106.84 mm(3) and 771.23 mm(3) for maxillary and mandibular ISPs, respectively). Conclusions: The results of the present report suggest that Scan/CAD/CAM method enables a more precise and accurate transfer of provisional restorations to final restorations compared to the conventional method. (C) 2014 Japan Prosthodontic Society. Published by Elsevier Ireland. All rights reserved.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 7 条
  • [1] Transfer of gingival contours to a master cast
    Breeding, LC
    Dixon, DL
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (03) : 341 - 343
  • [2] Buskin R, 1998, Pract Periodontics Aesthet Dent, V10, P1171
  • [3] Buskin R, 1998, PRACT PERIODONTICS A, V10, P1180
  • [4] Accurate transfer of peri-implant soft tissue emergence profile from the provisional crown to the final prosthesis using an emergence profile cast
    Elian, Nicolas
    Tabourian, Gerard
    Jalbout, Ziad N.
    Classi, Anthony
    Cho, Sang-Choon
    Froum, Stuart
    Tarnow, Dennis P.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2007, 19 (06) : 306 - 314
  • [5] Gonzalez-Martin O, 2014, J JPN SOC DENT PROD, V34, P673
  • [6] CAD/CAM FABRICATED COMPLETE DENTURES: CONCEPTS AND CLINICAL METHODS OF OBTAINING REQUIRED MORPHOLOGICAL DATA
    Goodacre, Charles J.
    Garbacea, Antoanela
    Naylor, W. Patrick
    Daher, Tony
    Marchack, Christopher B.
    Lowry, Jean
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (01) : 34 - 46
  • [7] Moscovitch M S, 1996, Int J Oral Maxillofac Implants, V11, P395