Plasmonic Fluor-Enhanced Antigen Arrays for High-Throughput, Serological Studies of SARS-CoV-2

被引:0
作者
Qavi, Abraham J. [1 ]
Wu, Chao [1 ]
Lloyd, Matthew [1 ]
Zaman, Mohammad Mahabub-Uz [2 ]
Luan, Jingyi [2 ,3 ]
Ballman, Claire [1 ]
Leung, Daisy W. [4 ]
Crick, Scott L. [2 ]
Farnsworth, Christopher W. [1 ]
Amarasinghe, Gaya K. [1 ]
机构
[1] Washington Univ Sch Med, Dept Pathol & Immunol, St Louis, MO 63110 USA
[2] Auragent Biosci, St Louis, MO 63108 USA
[3] Harvard Univ, Wyss Inst Biolog Inspired Engn, Boston, MA 02115 USA
[4] Washington Univ Sch Med, Dept Internal Med, St Louis, MO 63110 USA
来源
ACS INFECTIOUS DISEASES | 2022年 / 8卷 / 08期
关键词
plasmonics; serology; screening; SARS-CoV-2; diagnostics; RECOMMENDATIONS; IDENTIFICATION; BIOMARKERS; ANTIBODIES; INFECTION;
D O I
10.1021/acsinfecdis.2c000861468
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Serological testing for acute infection or prior exposure is critical for patient management and coordination of public health decisions during outbreaks. Current methods have several limitations, including variable performance, relatively low analytical and clinical sensitivity, and poor detection due to antigenic drift. Serological methods for SARS-CoV-2 detection for the ongoing COVID-19 pandemic suffer from several of these limitations and serves as a reminder of the critical need for new technologies. Here, we describe the use of ultrabright fluorescent reagents, Plasmonic Fluors, coupled with antigen arrays that address a subset of these limitations. We demonstrate its application using patient samples in SARS-CoV-2 serological assays. In our multiplexed assay, SARS-CoV-2 antigens were spotted into 48-plex arrays within a single well of a 96-well plate and used to evaluate remnant laboratory samples of SARS-CoV-2 positive patients. Signal-readout was performed with Auragent Bioscience's Empower microplate reader, and microarray analysis software. Sample volumes of 1 mu L were used. High sensitivity of the Plasmonic Fluors combined with the array format enabled us to profile patient serological response to eight distinct SARS-CoV-2 antigens and evaluate responses to IgG, IgM, and IgA. Sensitivities for SARS-CoV-2 antigens during the symptomatic state ranged between 72.5 and 95.0%, specificity between 62.5 and 100%, and the resulting area under the curve values between 0.76 and 0.97. Together, these results highlight the increased sensitivity for low sample volumes and multiplex capability. These characteristics make Plasmonic Fluor-enhanced antigen arrays an attractive technology for serological studies for the COVID-19 pandemic and beyond.
引用
收藏
页码:1468 / 1479
页数:12
相关论文
共 63 条
  • [1] Amanat F, 2020, NAT MED, V26, P1033, DOI [10.1038/s41591-020-0913-5, 10.1101/2020.03.17.20037713]
  • [2] Seasonal human coronavirus antibodies are boosted upon SARS-CoV-2 infection but not associated with protection
    Anderson, Elizabeth M.
    Goodwin, Eileen C.
    Verma, Anurag
    Arevalo, Claudia P.
    Bolton, Marcus J.
    Weirick, Madison E.
    Gouma, Sigrid
    McAllister, Christopher M.
    Christensen, Shannon R.
    Weaver, JoEllen
    Hicks, Philip
    Manzoni, Tomaz B.
    Oniyide, Oluwatosin
    Ramage, Holly
    Mathew, Divij
    Baxter, Amy E.
    Oldridge, Derek A.
    Greenplate, Allison R.
    Wu, Jennifer E.
    Alanio, Cecile
    D'Andrea, Kurt
    Kuthuru, Oliva
    Dougherty, Jeanette
    Pattekar, Ajinkya
    Kim, Justin
    Han, Nicholas
    Apostolidis, Sokratis A.
    Huang, Alex C.
    Vella, Laura A.
    Kuri-Cervantes, Leticia
    Pampena, M. Betina
    Betts, Michael R.
    Wherry, E. John
    Meyer, Nuala J.
    Cherry, Sara
    Bates, Paul
    Rader, Daniel J.
    Hensley, Scott E.
    [J]. CELL, 2021, 184 (07) : 1858 - +
  • [3] Enhancement and quenching of single-molecule fluorescence
    Anger, P
    Bharadwaj, P
    Novotny, L
    [J]. PHYSICAL REVIEW LETTERS, 2006, 96 (11)
  • [4] Agreement between self-report and medical records on signs and symptoms of respiratory illness
    Barbara, Angela M.
    Loeb, Mark
    Dolovich, Lisa
    Brazil, Kevin
    Russell, Margaret
    [J]. PRIMARY CARE RESPIRATORY JOURNAL, 2012, 21 (02): : 145 - 152
  • [5] Diagnostic accuracy of serological tests for covid-19: systematic review and meta-analysis
    Bastos, Mayara Lisboa
    Tavaziva, Gamuchirai
    Abidi, Syed Kunal
    Campbell, Jonathon R.
    Haraoui, Louis -Patrick
    Johnston, James C.
    Lan, Zhiyi
    Law, Stephanie
    MacLean, Emily
    Trajman, Anete
    Menzies, Dick
    Benedetti, Andrea
    Khan, Faiz Ahmad
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2020, 370
  • [6] Diagnosing infections--current and anticipated technologies for point-of-care diagnostics and home-based testing
    Bissonnette, L.
    Bergeron, M. G.
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2010, 16 (08) : 1044 - 1053
  • [7] Branson BM., 2014, LAB TEST DIAGN HIV I, DOI DOI 10.15620/CDC.23447
  • [8] Evaluation of Dried Blood Spot Testing for SARS-CoV-2 Serology Using a Quantitative Commercial Assay
    Brinc, Davor
    Biondi, Mia J.
    Li, Daniel
    Sun, Heng
    Capraru, Camelia
    Smookler, David
    Zahoor, Muhammad Atif
    Casey, Julia
    Kulasingam, Vathany
    Feld, Jordan J.
    [J]. VIRUSES-BASEL, 2021, 13 (06):
  • [9] Anemia, transfusion, and phlebotomy practices in critically ill patients with prolonged ICU length of stay: a cohort study
    Chant, Clarence
    Wilson, Gail
    Friedrich, Jan O.
    [J]. CRITICAL CARE, 2006, 10 (05):
  • [10] Diagnostic Testing for Severe Acute Respiratory Syndrome-Related Coronavirus 2 A Narrative Review
    Cheng, Matthew P.
    Papenburg, Jesse
    Desjardins, Michael
    Kanjilal, Sanjat
    Quach, Caroline
    Libman, Michael
    Dittrich, Sabine
    Yansouni, Cedric P.
    [J]. ANNALS OF INTERNAL MEDICINE, 2020, 172 (11) : 726 - +