Liquid-phase microextraction as an attractive tool for multielement trace analysis in combination with X-ray fluorescence spectrometry: an example of simultaneous determination of Fe, Co, Zn, Ga, Se and Pb in water samples

被引:30
作者
Sitko, Rafal [1 ]
Kocot, Karina [1 ]
Zawisza, Beata [1 ]
Feist, Barbara [1 ]
Pytlakowska, Katarzyna [1 ]
机构
[1] Univ Silesia, Inst Chem, PL-40006 Katowice, Poland
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; SINGLE-DROP MICROEXTRACTION; BIOLOGICAL SAMPLES; EXTRACTION; LEAD; PRECONCENTRATION; GENERATION; METALS; CD;
D O I
10.1039/c1ja10143a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In recent years, liquid-phase microextraction (LPME) has become one of the most valuable techniques for the preconcentration and separation of trace and ultratrace elements. LPME can be combined with an atomic technique which requires only a few microlitres of liquid to perform a measurement, e. g. electrothermal atomic absorption spectrometry. In this study, combining LPME with X-ray fluorescence spectrometry (XRF), a dried-spot technique is proposed. Since the X-ray beam can be focused on a small spot size and simultaneously LPME produces a very small drop of a volume ranging from 2 to 30 mu L, the combination of these two techniques is a very promising tool for multielement trace and ultratrace analyses. The present research was performed using dispersive liquid-liquid microextraction (DLLME) with APDC as a chelating agent. Nevertheless, any LPME technique, e. g. single-drop microextraction (SDME), can be applied in combination with XRF. Because XRF measurement follows the microextraction, deposition and drying of the small drop, the influence of the diameter of the dried residue on the intensity of fluorescent radiation is discussed in detail. Pipetting and spray-on techniques are proposed for the deposition of the small drop onto the substrate (membrane filter or Mylar foil). Under the optimized conditions, the detection limits were 2.8, 1.6, 2.5, 1.7, 2.1 and 4.1 ng mL(-1) for Fe, Co, Zn, Ga, Se and Pb, respectively, with a preconcentration factor of 250 for 5 mL of the water sample.
引用
收藏
页码:1979 / 1985
页数:7
相关论文
共 45 条
[11]   Picoliter Droplet Deposition Using a Prototype Picoliter Pipette: Control Parameters and Application in Micro X-ray Fluorescence [J].
Fittschen, Ursula E. A. ;
Havrilla, George J. .
ANALYTICAL CHEMISTRY, 2010, 82 (01) :297-306
[12]   Optimization of a single-drop microextraction method for multielemental determination by electrothermal vaporization inductively coupled plasma mass spectrometry following in situ vapor generation [J].
Gil, Sandra ;
de Loos-Vollebregt, Margaretha T. C. ;
Bendicho, Carlos .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (03) :208-214
[13]   Homogeneous liquid-liquid extraction followed by X-ray fluorescence spectrometry of a microdroplet on filter-paper for the simultaneous determination of small amounts of metals [J].
Igarashi, S ;
Takahashi, A ;
Ueki, Y ;
Yamaguchi, H .
ANALYST, 2000, 125 (05) :797-798
[14]   Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry - Ultra trace determination of cadmium in water samples [J].
Jahromi, Elham Zeini ;
Bidari, Araz ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani ;
Jamali, Mohammad Reza .
ANALYTICA CHIMICA ACTA, 2007, 585 (02) :305-311
[15]  
Janssens K.H. A., 2000, MICROSCOPIC XRAY FLU
[16]  
Klockenkamper R., 1997, Total Reflection X-ray Fluorescence Analysis
[17]  
Kregsamer P., 2002, Handbook of X-ray Spectrometry-Revised and Expanded, P559
[18]   Determination of trace Cd and Pb in environmental and biological samples by ETV-ICP-MS after single-drop microextraction [J].
Li, Li ;
Hu, Bin ;
Xia, Linbo ;
Jiang, Zucheng .
TALANTA, 2006, 70 (02) :468-473
[19]   Development of microwave-assisted drying methods for sample preparation for dried spot micro-X-ray fluorescence analysis [J].
Link, DD ;
Kingston, HM ;
Havrilla, GJ ;
Colletti, LP .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1165-+
[20]   A RENEWABLE LIQUID DROPLET AS A SAMPLER AND A WINDOWLESS OPTICAL-CELL - AUTOMATED SENSOR FOR GASEOUS CHLORINE [J].
LIU, HH ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4221-4228