Induction of hypocalcaemia and evaluation of reticuloruminal motility using a three-axis accelerometer

被引:0
作者
Choi, Woojae [1 ]
Ro, Younghye [1 ]
Kim, Dohee [1 ]
Hong, Leegon [1 ]
Kim, Danil [1 ,2 ]
机构
[1] Seoul Natl Univ, Coll Vet Med, Dept Farm Anim Med, Seoul 08826, South Korea
[2] Seoul Natl Univ, Inst Green Bio Sci & Technol, Farm Anim Clin Training & Res Ctr, Pyeongchang 25354, South Korea
基金
芬兰科学院;
关键词
dairy cows; detection of periparturient disease; calcium; forestomach motility in cattle; induced hypocalcaemia; remote sensing; smart farming; three-axis accelerometer; SUBCLINICAL HYPOCALCEMIA; METABOLIC PREDICTORS; EDTA INFUSION; CALCIUM; MAGNESIUM; BLOOD; RUMINATION; PHOSPHATE; RISK; COWS;
D O I
10.1071/AN21532
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Context Reticuloruminal motility, which is continuous and regular, is essential for digestive activity, but some functional abnormalities can appear in cattle with several metabolic disorders. Particularly in periparturient dairy cows, decreased blood calcium concentrations induce deterioration of rumen motility as well as the risk of reproductive disorders. Aims This study aimed to evaluate reticuloruminal motility using a bolus-type biosensor incorporated with a three-axis accelerometer (3XA) following induction of hypocalcaemia by infusion of ethylenediamine-tetraacetic acid disodium salt dihydrate (Na(2)EDTA) solution. Methods In the 2 x 2 crossover experiment, six non-pregnant and non-lactating cows were assigned to each of the treatment (TRE) and control (CON) groups and infused for 1 h with 13% Na(2)EDTA solution and physiological saline respectively. The cylindrical biosensor was fed and placed in the reticulum before the experiment, and the three acceleration values of each cow were recorded and transmitted wirelessly. Considering the device shape, the reticuloruminal motility was represented as the vector value (V-2) calculated with each change in X- and Z-axis acceleration over time. Key results Plasma calcium concentrations were measured to confirm hypocalcaemia, and the average was significantly decreased to 1.23 mmol/L at 1 h in TRE. The mean V-2 value was significantly decreased in TRE compared with CON, from 1 to 2 h after Na(2)EDTA infusion. Conclusion 3XA was able to detect a change in reticuloruminal motility caused by hypocalcaemia. The use of 3XA in cattle will allow for rapid treatment of hypocalcaemia or other metabolic disorders that reduce productivity. Implications The 3XA inserted into the reticulum of a dairy cow detected a decrease in reticuloruminal motility wirelessly caused by induced hypocalcaemia.
引用
收藏
页码:409 / 415
页数:7
相关论文
共 31 条
  • [21] Behavioral modeling of a monolithically integrated three-axis capacitive accelerometer based on the MetalMUMPs process
    Iqbal, Abid
    Bazaz, Shafaat A.
    SIMULATION-TRANSACTIONS OF THE SOCIETY FOR MODELING AND SIMULATION INTERNATIONAL, 2012, 88 (05): : 565 - 579
  • [22] Sensitivity calibration of a three-axis accelerometer under different temperature conditions using the hybrid GA-PSO-BPNN algorithm
    Du, Cuicui
    Kong, Deren
    SENSOR REVIEW, 2022, 42 (01) : 8 - 18
  • [23] Research on a physical activity tracking system based upon three-axis accelerometer for patients with leg ulcers
    Yan, Rongguo
    Zhao, Weibing
    Sun, Qi
    HEALTHCARE TECHNOLOGY LETTERS, 2019, 6 (05) : 147 - 152
  • [24] The First 3D-Printed and Wet-Metallized Three-Axis Accelerometer With Differential Capacitive Sensing
    Zega, Valentina
    Invernizzi, Marta
    Bernasconi, Roberto
    Cuneo, Federico
    Langfelder, Giacomo
    Magagnin, Luca
    Levi, Marinella
    Corigliano, Alberto
    IEEE SENSORS JOURNAL, 2019, 19 (20) : 9131 - 9138
  • [25] Using Three-axis Acceleration Sensor to Measure the Frequency of the Precession Vortex Signal
    Xu, Ying
    Wei, Chuan-Shun
    Yuan, Chao
    Cao, Lin-Fei
    Zuo, Rong-Ji
    Liu, Ye
    Ba, Xi-Li
    2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [26] Development of a three-axis accelerometer and large-scale particle image velocimetry (LSPIV) to enhance surface velocity measurements in rivers
    Liu, Wen-Cheng
    Huang, Wei-Che
    COMPUTERS & GEOSCIENCES, 2021, 155
  • [27] Magnetic Anomaly Detection Using Continuous Angle Alignment of Three-Axis Magnetic Signal
    Kim, Kwang-Yul
    Jeong, Euicheol
    Kim, Seongil
    Shin, Yoan
    IEEE SENSORS JOURNAL, 2019, 19 (02) : 743 - 750
  • [28] Localization of Sliding Movements Using Soft Tactile Sensing Systems with Three-axis Accelerometers
    Trinh, Hiep Xuan
    Iwamoto, Yuki
    Van Anh Ho
    Shibuya, Koji
    SENSORS, 2019, 19 (09)
  • [29] The relationships between three-axis accelerometer measures of physical activity and motor symptoms in patients with Parkinson's disease: a single-center pilot study
    Ito, Hiroto
    Yokoi, Daichi
    Kobayashi, Rei
    Okada, Hisashi
    Kajita, Yasukazu
    Okuda, Satoshi
    BMC NEUROLOGY, 2020, 20 (01)
  • [30] Predicting a Fall Based on Gait Anomaly Detection: A Comparative Study of Wrist-Worn Three-Axis and Mobile Phone-Based Accelerometer Sensors
    Kocuvan, Primoz
    Hrastic, Aleksander
    Kareska, Andrea
    Gams, Matjaz
    SENSORS, 2023, 23 (19)