Induction of hypocalcaemia and evaluation of reticuloruminal motility using a three-axis accelerometer

被引:0
作者
Choi, Woojae [1 ]
Ro, Younghye [1 ]
Kim, Dohee [1 ]
Hong, Leegon [1 ]
Kim, Danil [1 ,2 ]
机构
[1] Seoul Natl Univ, Coll Vet Med, Dept Farm Anim Med, Seoul 08826, South Korea
[2] Seoul Natl Univ, Inst Green Bio Sci & Technol, Farm Anim Clin Training & Res Ctr, Pyeongchang 25354, South Korea
基金
芬兰科学院;
关键词
dairy cows; detection of periparturient disease; calcium; forestomach motility in cattle; induced hypocalcaemia; remote sensing; smart farming; three-axis accelerometer; SUBCLINICAL HYPOCALCEMIA; METABOLIC PREDICTORS; EDTA INFUSION; CALCIUM; MAGNESIUM; BLOOD; RUMINATION; PHOSPHATE; RISK; COWS;
D O I
10.1071/AN21532
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Context Reticuloruminal motility, which is continuous and regular, is essential for digestive activity, but some functional abnormalities can appear in cattle with several metabolic disorders. Particularly in periparturient dairy cows, decreased blood calcium concentrations induce deterioration of rumen motility as well as the risk of reproductive disorders. Aims This study aimed to evaluate reticuloruminal motility using a bolus-type biosensor incorporated with a three-axis accelerometer (3XA) following induction of hypocalcaemia by infusion of ethylenediamine-tetraacetic acid disodium salt dihydrate (Na(2)EDTA) solution. Methods In the 2 x 2 crossover experiment, six non-pregnant and non-lactating cows were assigned to each of the treatment (TRE) and control (CON) groups and infused for 1 h with 13% Na(2)EDTA solution and physiological saline respectively. The cylindrical biosensor was fed and placed in the reticulum before the experiment, and the three acceleration values of each cow were recorded and transmitted wirelessly. Considering the device shape, the reticuloruminal motility was represented as the vector value (V-2) calculated with each change in X- and Z-axis acceleration over time. Key results Plasma calcium concentrations were measured to confirm hypocalcaemia, and the average was significantly decreased to 1.23 mmol/L at 1 h in TRE. The mean V-2 value was significantly decreased in TRE compared with CON, from 1 to 2 h after Na(2)EDTA infusion. Conclusion 3XA was able to detect a change in reticuloruminal motility caused by hypocalcaemia. The use of 3XA in cattle will allow for rapid treatment of hypocalcaemia or other metabolic disorders that reduce productivity. Implications The 3XA inserted into the reticulum of a dairy cow detected a decrease in reticuloruminal motility wirelessly caused by induced hypocalcaemia.
引用
收藏
页码:409 / 415
页数:7
相关论文
共 31 条
  • [1] A monolithic three-axis accelerometer with symmetric properties
    Rödjegård, H
    Andersson, G
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 442 - 445
  • [2] Motion Recognition Based on a Three-Axis Accelerometer
    Chen Yang
    Xu Lin
    Zhao Lulu
    Yang Yuliang
    Fu Anqi
    Wang Meng
    2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 3703 - 3708
  • [3] Ambulatory balance monitoring using a wireless attachable three-axis accelerometer
    Kim, Soo-Chan
    Kim, Mi Joo
    Kim, Nambeom
    Hwang, Jong Hyun
    Han, Gyu Cheol
    JOURNAL OF VESTIBULAR RESEARCH-EQUILIBRIUM & ORIENTATION, 2013, 23 (4-5): : 217 - 225
  • [4] Development of a System for Measurement and Analysis of Tremor Using a Three-axis Accelerometer
    Mamorita, N.
    Iizuka, T.
    Takeuchi, A.
    Shirataka, M.
    Ikeda, N.
    METHODS OF INFORMATION IN MEDICINE, 2009, 48 (06) : 589 - 594
  • [5] Benchmarking 'Radio Exercises' Recognition with a Three-axis Accelerometer
    Terumoto, Akio
    Inoue, Sozo
    Hattori, Yuichi
    2011 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2011, : 41 - 45
  • [6] Estimate activity for M-health using one three-axis accelerometer
    Akahori, Akimitsu
    Kishimoto, Yoshifumi
    Oguri, Koji
    2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS, 2006, : 122 - +
  • [7] A differential capacitive three-axis SOI accelerometer using vertical comb electrodes
    Hamaguchi, H.
    Sugano, K.
    Tsuchiya, T.
    Tabata, O.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [8] Noise and reliability measurement of a three-axis micro-accelerometer
    Mohd-Yasin, F.
    Zaiyadi, N.
    Nagel, D. J.
    Ong, D. S.
    Korman, C. E.
    Faidz, A. R.
    MICROELECTRONIC ENGINEERING, 2009, 86 (4-6) : 991 - 995
  • [9] The establishment and application of a novel spherical sensor based on three-axis accelerometer
    Li, Hengjun
    Ma, Shaojian
    Yang, Xiaojing
    Zhu, Pengyan
    Wang, Dingzheng
    Li, Yuan
    Yang, Jinlin
    ADVANCED POWDER TECHNOLOGY, 2025, 36 (04)
  • [10] Design and Fabrication of a Differential Capacitive Three-Axis SOI Accelerometer Using Vertical Comb Electrodes
    Tsuchiya, Toshiyuki
    Hamaguchi, Hiroyuki
    Sugano, Koji
    Tabata, Osamu
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2009, 4 (03) : 345 - 351