Investigation of heat loss from a solar cavity receiver

被引:33
作者
Abbasi-Shavazi, E. [1 ]
Hughes, G. O. [2 ]
Pye, J. D. [1 ]
机构
[1] Australian Natl Univ, Res Sch Engn, Solar Thermal Grp, Canberra, ACT 0200, Australia
[2] Australian Natl Univ, Res Sch Earth Sci, Canberra, ACT 0200, Australia
来源
INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, SOLARPACES 2014 | 2015年 / 69卷
关键词
Experimental heat transfer; Convection heat loss; Receiver design; NATURAL-CONVECTION;
D O I
10.1016/j.egypro.2015.03.031
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study examines experimentally the heat loss from a model solar cavity receiver. For this purpose, laboratory-scale cylindrical cavity models with geometric aspect ratios (cavity length to diameter) of 1 and 2, and aperture opening ratios (aperture diameter to cavity diameter) of 0.5 and 1, were built. Each cavity was subjected to constant boundary heat input via heating cables, and was operated at various downward inclinations. A carefully-applied coating of Pyromark-2500 heat resistant paint on the cavity surface, in conjunction with steady-state experimental temperatures, enabled accurate calculation of the radiative loss from the cavities. The experimental technique allowed precise control of the operating parameters, resulting in determination of the conduction loss, and subsequently, the convection heat loss. Operation at temperatures up to 650 degrees C allowed for a better understanding of the interaction between radiation and convection heat loss mechanisms. Experimental data obtained in this study are shown to be consistent with the concept of stagnation and convection zone development in cavities, with increasing cavity inclination angle. A qualitative assessment of the impact of these zones on the cavity surface temperatures is presented. Whereas thermocouples located in stagnation region show uniform temperature distribution, the surfaces which are exposed to convective flows exhibit larger temperature variations. The temperature distribution along the cavity walls and its effect on radiative loss calculation is also investigated in this work. It is seen that radiative loss predictions which consider an average cavity temperature in their model can overestimate the losses due to this mechanism by up to 20%, in comparison to models which use experimental temperatures along the cavity interior. Convection loss from the cavity is calculated and compared with results from correlations proposed in the literature. It is seen that correlations based on surface areas of the stagnation and convection zones are better at predicting the experimental results. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:269 / 278
页数:10
相关论文
共 21 条
[1]   NATURAL-CONVECTION FROM ISOTHERMAL CUBICAL CAVITIES WITH A VARIETY OF SIDE-FACING APERTURES [J].
CLAUSING, AM ;
WALDVOGEL, JM ;
LISTER, LD .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1987, 109 (02) :407-412
[2]   AN ANALYSIS OF CONVECTIVE LOSSES FROM CAVITY SOLAR CENTRAL RECEIVERS [J].
CLAUSING, AM .
SOLAR ENERGY, 1981, 27 (04) :295-300
[3]  
Eyler L.L., 1980, P CENT 2 SOL EN C SA
[4]   THERMAL PERFORMANCE OF SOLAR CONCENTRATOR CAVITY RECEIVER SYSTEMS [J].
HARRIS, JA ;
LENZ, TG .
SOLAR ENERGY, 1985, 34 (02) :135-142
[5]  
Ho CK, 2012, 6 INT C EN SUST 10 F
[6]  
Jilte R.D., 2013, Mechanical Engineering Research, V3, P25, DOI DOI 10.5539/MER.V3N1P25
[7]  
Le Quere P., 1981, Sandia Laboratory Report No. SAND81-8014
[8]   CONVECTIVE HEAT-LOSS FROM UPWARD AND DOWNWARD-FACING CAVITY SOLAR RECEIVERS - MEASUREMENTS AND CALCULATIONS [J].
LEIBFRIED, U ;
ORTJOHANN, J .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (02) :75-84
[9]  
McDonlad CG, 1985, SAND952939 SAND NAT
[10]  
NREL, 2012, DOEGO1020123037 NREL