Chiral separation of beta-adrenergic antagonists, profen non-steroidal anti-inflammatory drugs and chlorophenoxypropionic acid herbicides using teicoplanin as the chiral selector in capillary liquid chromatography

被引:34
作者
Kafková, B
Bosáková, Z
Tesarová, E
Coufal, P
机构
[1] Charles Univ Prague, Fac Sci, Dept Analyt Chem, Prague 12840 2, Czech Republic
[2] Charles Univ Prague, Fac Sci, Dept Phys & Macromol Chem, Prague 12840 2, Czech Republic
关键词
chiral stationary phases; LC; enantiomer separation; teicoplanin; beta-adrenergic antagonists; profen NSAIDs; chlorophenoxypropionic acids;
D O I
10.1016/j.chroma.2005.02.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three groups of structurally diverse chiral compounds were used to study the interaction mechanism responsible for stereoselective recognition with teicoplanin as chiral selector in capillary liquid chromatography. Teicoplanin-based chiral stationary phase (CSP) was used. The effect of the variation of mobile phase composition on retention and enantioselective separation was studied. The mobile phase composition suitable for enantioresolution of the various chiral compounds differed according to the interaction forces needed for chiral recognition. Mobile phases with high buffer portion (70-90vol.%) were preferred for separation of enantiomers of profen non-steroidal anti-inflammatory drugs and chlorophenoxypropionic acid herbicides that require hydrophobic interactions, inclusion and pi-pi interactions for stereoselective recognition with teicoplanin. Higher concentration triethylamine in the buffer (0.5-1.0%) increased resolution of these acids. On the other hand, H-bonding and electrostatic interactions are important in stereoselective interaction mechanism of beta-adrenergic antagonists with teicoplanin. These interaction types predominate in the reversed phase separation mode with high organic modifier content (95% methanol) and in polar organic mobile phases. For this reason beta-adrenergic antagonists were best enantioresolved in the polar organic mode. The mobile phase composed of methanol/acetic acid/triethylamine, 100/0.01/0.01 (v/v/v), provided enantioresolution values of all the studied beta-adrenergic antagonists in the range 1.1-1.9. Addition of teicoplanin to the mobile phase, which was suitable for enantio separation of certain compounds on the CSP, was also investigated. This system was used to dispose of nonstereoselective interactions of analytes with silica gel support that often participate in the interaction with CSPs. Very low concentration of teicoplanin in the mobile phase (0.1 mM) resulted in enantioselective separation of 2,2- and 2,4-chlorophenoxypropionic acids. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 93
页数:12
相关论文
empty
未找到相关数据