Automatic tracking of medial gastrocnemius fascicle length during human locomotion

被引:176
作者
Cronin, Neil J. [1 ]
Carty, Christopher P. [1 ]
Barrett, Rod S. [1 ]
Lichtwark, Glen [2 ]
机构
[1] Griffith Univ, Griffith Hlth Inst, Musculoskeletal Res Program, Nathan, Qld 4111, Australia
[2] Univ Queensland, Sch Human Movement Studies, Brisbane, Qld 4072, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
ultrasonography; affine flow; muscle fascicle; walking; running; IN-VIVO; ACHILLES-TENDON; MUSCLE-TENDON; ULTRASOUND; GAIT; REPEATABILITY; BEHAVIOR; WALKING;
D O I
10.1152/japplphysiol.00530.2011
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Cronin NJ, Carty CP, Barrett RS, Lichtwark G. Automatic tracking of medial gastrocnemius fascicle length during human locomotion. J Appl Physiol 111: 1491-1496, 2011. First published August 11, 2011; doi: 10.1152/japplphysiol.00530.2011.-During human locomotion lower extremity muscle-tendon units undergo cyclic length changes that were previously assumed to be representative of muscle fascicle length changes. Measurements in cats and humans have since revealed that muscle fascicle length changes can be uncoupled from those of the muscle-tendon unit. Ultrasonography is frequently used to estimate fascicle length changes during human locomotion. Fascicle length analysis requires time consuming manual methods that are prone to human error and experimenter bias. To bypass these limitations, we have developed an automatic fascicle tracking method based on the Lucas-Kanade optical flow algorithm with an affine optic flow extension. The aims of this study were to compare gastrocnemius fascicle length changes during locomotion using the automated and manual approaches and to determine the repeatability of the automated approach. Ultrasound was used to examine gastrocnemius fascicle lengths in eight participants walking at 4, 5, 6, and 7 km/h and jogging at 7 km/h on a treadmill. Ground reaction forces and three dimensional kinematics were recorded simultaneously. The level of agreement between methods and the repeatability of the automated method were quantified using the coefficient of multiple correlation (CMC). Regardless of speed, the level of agreement between methods was high, with overall CMC values of 0.90 +/- 0.09 (95% CI: 0.86-0.95). Repeatability of the algorithm was also high, with an overall CMC of 0.88 +/- 0.08 (95% CI: 0.79-0.96). The automated fascicle tracking method presented here is a robust, reliable, and time-efficient alternative to the manual analysis of muscle fascicle length during gait.
引用
收藏
页码:1491 / 1496
页数:6
相关论文
共 30 条
  • [1] Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo
    Aggeloussis, Nickos
    Giannakou, Erasmia
    Albracht, Kirsten
    Arampatzis, Adamantios
    [J]. GAIT & POSTURE, 2010, 31 (01) : 73 - 77
  • [2] Lucas-Kanade 20 years on: A unifying framework
    Baker, S
    Matthews, I
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 2004, 56 (03) : 221 - 255
  • [3] ANATOMICAL INFORMATION IS NEEDED IN ULTRASOUND IMAGING OF MUSCLE TO AVOID POTENTIALLY SUBSTANTIAL ERRORS IN MEASUREMENT OF MUSCLE GEOMETRY
    Benard, Menno R.
    Becher, Jules G.
    Harlaar, Jaap
    Huijing, Peter A.
    Jaspers, Richard T.
    [J]. MUSCLE & NERVE, 2009, 39 (05) : 652 - 665
  • [4] Repeatability of gait data using a functional hip joint centre and a mean helical knee axis
    Besier, TF
    Sturnieks, DL
    Alderson, JA
    Lloyd, DG
    [J]. JOURNAL OF BIOMECHANICS, 2003, 36 (08) : 1159 - 1168
  • [5] Differential displacement of the human soleus and medial gastrocnemius aponeuroses during isometric plantar flexor contractions in vivo
    Bojsen-Moller, J
    Hansen, P
    Aagaard, P
    Svantesson, U
    Kjaer, M
    Magnusson, SP
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2004, 97 (05) : 1908 - 1914
  • [6] Ultrasonography as a tool to study afferent feedback from the muscle-tendon complex during human walking
    Cronin, Neil J.
    af Klint, Richard
    Grey, Michael J.
    Sinkjaer, Thomas
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2011, 21 (02) : 197 - 207
  • [7] Achilles tendon length changes during walking in long-term diabetes patients
    Cronin, Neil J.
    Peltonen, Jussi
    Ishikawa, Masaki
    Komi, Paavo V.
    Avela, Janne
    Sinkjaer, Thomas
    Voigt, Michael
    [J]. CLINICAL BIOMECHANICS, 2010, 25 (05) : 476 - 482
  • [8] OpenSim: open-source software to create and analyze dynamic Simulations of movement
    Delp, Scott L.
    Anderson, Frank C.
    Arnold, Allison S.
    Loan, Peter
    Habib, Ayman
    John, Chand T.
    Guendelman, Eran
    Thelen, Darryl G.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (11) : 1940 - 1950
  • [9] AN INTERACTIVE GRAPHICS-BASED MODEL OF THE LOWER-EXTREMITY TO STUDY ORTHOPEDIC SURGICAL-PROCEDURES
    DELP, SL
    LOAN, JP
    HOY, MG
    ZAJAC, FE
    TOPP, EL
    ROSEN, JM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (08) : 757 - 767
  • [10] A new formulation of the coefficient of multiple correlation to assess the similarity of waveforms measured synchronously by different motion analysis protocols
    Ferrari, Alberto
    Cutti, Andrea Giovanni
    Cappello, Angelo
    [J]. GAIT & POSTURE, 2010, 31 (04) : 540 - 542