Comparison of Signal Detection of GaAsP and GaAs PMTs for Multiphoton Microscopy at the 1700-nm window

被引:13
作者
Wang, Yuxin [1 ]
Wang, Kai [1 ]
Wen, Wenhui [1 ]
Qiu, Ping [2 ]
Wang, Ke [1 ]
机构
[1] Shenzhen Univ, Coll Optoelect Engn, Key Lab Optoelect Devices & Syst, Minist Educ & Guangdong Prov, Shenzhen 518060, Peoples R China
[2] Shenzhen Univ, Coll Phys & Energy, Shenzhen 518060, Peoples R China
来源
IEEE PHOTONICS JOURNAL | 2016年 / 8卷 / 03期
基金
中国国家自然科学基金;
关键词
Fluorescence microscopy; nonlinear microscopy; multiphoton processes; IN-VIVO; DEEP TISSUE; MU-M; RESOLUTION; NEURONS;
D O I
10.1109/JPHOT.2016.2570005
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Multiphoton microscopy (MPM) enables noninvasive optical imaging into the deep tissue in animal models in vivo. Recently, 1700 nm has been demonstrated as a promising excitation window for deeper penetration. Signal depletion is currently the limiting factor for imaging depth at the 1700-nm window in MPM. As a result, efficient signal detection is an effective means to further boost imaging depth. GaAsP and GaAs photo-ultiplier tubes (PMTs) are commonly used for signal detection in MPM. Here, we demonstrate a comparison investigation of signal detection of a GaAsP and a GaAs PMT for several modalities of MPM at 1700 nm. The two PMTs are identical in structure, connected to the same electronics, and mounted at exactly the same place in the microscope, facilitating a fair comparison. Our results show that with a 1667-nm excitation, GaAsP PMT is more efficient for signal detection of a 3-photon fluorescence of quantum dot Qtracker 655, third-harmonic generation signal, and a 4-photon fluorescence of fluorescein, whereas GaAs PMT is far superior in detecting a second-harmonic generation signal. The measured results are in good agreement with theoretical calculations based on wavelength-dependent cathode radiant sensitivities. We expect that our results will offer guidelines for PMT selection for MPM at the 1700-nm window.
引用
收藏
页数:6
相关论文
共 26 条
[1]   Ultra-deep two-photon fluorescence excitation in turbid media [J].
Beaurepaire, E ;
Oheim, M ;
Mertz, J .
OPTICS COMMUNICATIONS, 2001, 188 (1-4) :25-29
[2]   Measurements of multiphoton action cross sections for multiphoton microscopy [J].
Cheng, Li-Chung ;
Horton, Nicholas G. ;
Wang, Ke ;
Chen, Shean-Jen ;
Xu, Chris .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (10) :3427-3433
[3]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[4]   Functional imaging of hippocampal place cells at cellular resolution during virtual navigation [J].
Dombeck, Daniel A. ;
Harvey, Christopher D. ;
Tian, Lin ;
Looger, Loren L. ;
Tank, David W. .
NATURE NEUROSCIENCE, 2010, 13 (11) :1433-U180
[5]  
Hell S W, 1996, J Biomed Opt, V1, P71, DOI 10.1117/12.229062
[6]  
Horton Nicholas G., 2013, 2013 Conference on Lasers & Electro-Optics. Europe & International Quantum Electronics Conference (CLEO EUROPE/IQEC), DOI 10.1109/CLEOE-IQEC.2013.6801501
[7]  
Horton NG, 2013, NAT PHOTONICS, V7, P205, DOI [10.1038/nphoton.2012.336, 10.1038/NPHOTON.2012.336]
[8]  
Ji N, 2009, NAT METHODS, V6, P179, DOI [10.1038/nmeth0209-179, 10.1038/nmeth.1411]
[9]   Visualizing hippocampal neurons with in vivo two-photon microscopy using a 1030 nm picosecond pulse laser [J].
Kawakami, Ryosuke ;
Sawada, Kazuaki ;
Sato, Aya ;
Hibi, Terumasa ;
Kozawa, Yuichi ;
Sato, Shunichi ;
Yokoyama, Hiroyuki ;
Nemoto, Tomomi .
SCIENTIFIC REPORTS, 2013, 3
[10]   Imaging in vivo:: watching the brain in action [J].
Kerr, Jason N. D. ;
Denk, Winfried .
NATURE REVIEWS NEUROSCIENCE, 2008, 9 (03) :195-205