A first and second law analysis of a thermoresponsive polymer desiccant dehumidification and cooling cycle

被引:14
|
作者
Kocher, Jordan D. [1 ,2 ]
Yee, Shannon K. [2 ,3 ]
Wang, Robert Y. [1 ]
机构
[1] Arizona State Univ, Sch Engn Matter Transport & Energy, Tempe, AZ 85287 USA
[2] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[3] Natl Renewable Energy Lab, Golden, CO 80401 USA
关键词
Cooling; Air Conditioning; Dehumidification; Desiccant; Thermoresponsive; LCST; N-ISOPROPYLACRYLAMIDE; BEHAVIOR; TRANSITION; HYDROGELS;
D O I
10.1016/j.enconman.2021.115158
中图分类号
O414.1 [热力学];
学科分类号
摘要
We present a theoretical description for a new desiccant air conditioning cycle that uses thermoresponsive polymers instead of traditional desiccants. We use a combined first and second law analysis to demonstrate that this new cycle has three major advantages relative to the traditional case: (i) it can regenerate at lower temperatures, (ii) it can harvest liquid water and (iii) it has significantly higher coefficients of performance (COPs). For example, this new cycle can achieve a COP of 5.1 when regenerated at 95 degrees C, whereas the traditional desiccant cycle is limited to a COP of similar to 1. The fundamental origins of these advantages can be traced to the method of regeneration. The traditional desiccant cycle regenerates by flowing hot air over the desiccant, which provides a medium for gaseous water desorption. However, this also generates entropy and places a minimum temperature constraint on the hot air. In contrast, the thermoresponsive polymer cycle regenerates through a polymer phase transition. The polymer absorbs water vapor in humid air, and then it expels liquid water when raised above its transition temperature. This regeneration method generates liquid water that can be harvested and relaxes constraints on entropy generation and minimum temperature. The minimum regeneration temperature of the thermoresponsive cycle is only limited by the transition temperature of the polymer, which can be tuned through materials science. Due to its liquid water harvesting capability, the new cycle potentially eliminates water consumption when used with evaporative cooling, or it can be directly used for atmospheric water harvesting.
引用
收藏
页数:14
相关论文
共 14 条
  • [1] Effect of ambient conditions on the first and second law performance of an open desiccant cooling process
    Kanoglu, Mehmet
    Bolatturk, Ali
    Altuntop, Necdet
    RENEWABLE ENERGY, 2007, 32 (06) : 931 - 946
  • [2] Effect of operation conditions on the second law analysis of a desiccant cooling system
    Uckan, Irfan
    Yilmaz, Tuncay
    Buyukalaca, Orhan
    APPLIED THERMAL ENGINEERING, 2017, 113 : 1256 - 1265
  • [3] Development of a novel rotary desiccant cooling cycle with isothermal dehumidification and regenerative evaporative cooling using thermodynamic analysis method
    La, D.
    Li, Y.
    Dai, Y. J.
    Ge, T. S.
    Wang, R. Z.
    ENERGY, 2012, 44 (01) : 778 - 791
  • [4] Generalization of second law efficiency for next-generation cooling and dehumidification systems
    Lu, Zechao
    Fix, Andrew J.
    Warsinger, David M.
    Braun, James E.
    Ziviani, Davide
    ENERGY CONVERSION AND MANAGEMENT, 2024, 300
  • [5] Thermal analysis of a direct evaporative cooling system enhancement with desiccant dehumidification for vehicular air conditioning
    Alahmer, Ali
    APPLIED THERMAL ENGINEERING, 2016, 98 : 1273 - 1285
  • [6] Second law analysis of chemical dehumidification systems
    Marletta, L
    Evola, G
    Sicurella, F
    Garozzo, R
    ENERGY FOR BUILDINGS, 2004, : 312 - 319
  • [7] Performance analysis of air cycle refrigerator integrated desiccant system for cooling and dehumidifying warehouse
    Elsayed, S. S.
    Miyazaki, T.
    Hamamoto, Y.
    Akisawa, A.
    Kashiwagi, T.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (02): : 189 - 196
  • [8] Analysis of a novel solid desiccant evaporative cooling system integrated with a humidification-dehumidification desalination unit
    Lai, Lanbo
    Wang, Xiaolin
    Kefayati, Gholamreza
    Hu, Eric
    DESALINATION, 2023, 550
  • [9] Numerical Analysis of Optimising Liquid Desiccant Dehumidification for Sustainable Building Cooling: A Data-Driven Method Using Response Surface Methodology
    Hilal, Mohammed Azeez
    Abbas, Saleem Jasim
    PROCESSES, 2024, 12 (11)
  • [10] Thermodynamic analysis of an open cycle solid desiccant cooling system using Artificial Neural Network
    Koronaki, I. P.
    Rogdakis, E.
    Kakatsiou, T.
    ENERGY CONVERSION AND MANAGEMENT, 2012, 60 : 152 - 160