The mechanical behavior of as received and retrieved nickel titanium orthodontic archwires

被引:14
作者
Lombardo, Luca [1 ]
Toni, Giorgia [1 ]
Mazzanti, Valentina [2 ]
Mollica, Francesco [2 ]
Spedicato, Giorgio Alfredo [1 ]
Siciliani, Giuseppe [1 ]
机构
[1] Univ Ferrara, Postgrad Sch Orthodont, Via Borsari 46, I-44121 Ferrara, Italy
[2] Univ Ferrara, Dept Engn, Ferrara, Italy
关键词
Retrieved NiTi archwire; Fatigue; Mechanical behavior; LOAD-DEFLECTION CHARACTERISTICS; NI-TI WIRES; TEMPERATURE; FAILURE; FATIGUE;
D O I
10.1186/s40510-018-0251-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesThe aim of this study is to investigate and compare the characteristics of as received and retrieved NiTi archwires at a constant temperature by plotting their load/deflection graphs and quantifying three parameters describing the discharge plateau phase.Materials and methodsTwo hundred four NiTi archwires, traditional and heat-activated, of various cross sections, were obtained from 5 different manufacturers. Specimens prepared from the selected wires were subjected to a three-point bending test where 92 were retrieved through an in vivo retrieval protocol (crowding group C1 and group C2), 56 went through an in vitro retrieval protocol, and 56 were as received. The in vitro retrieval protocol was performed by a gear motor connected to a stainless steel support that performed fatigue cycles to the bent wires in artificial saliva. The load/deflection graphs of as received and retrieved wires were described through three parameters and the results were analyzed with classification and regression trees (CART) and analysis of variance (ANOVA).ResultsStatistically significant differences between as received and retrieved wires were found only for the parameter plateau slope which represents the constancy of force expressed by the wire.ConclusionsThe aging of NiTi archwires influences the force constancy expressed. The behavior of the wires changes depending on the size, brand, and type of retrieval protocol. In terms of performance, the poorest is represented by all wires retrieved in vitro and in vivo group C2 (moderate to severe crowding).
引用
收藏
页数:8
相关论文
共 26 条
  • [1] Load-deflection characteristics of superelastic nickel-titanium wires
    Bartzela, Theodosia N.
    Senn, Christiane
    Wichelhaus, Andrea
    [J]. ANGLE ORTHODONTIST, 2007, 77 (06) : 991 - 998
  • [2] Estimating arch length discrepancy through Little's Irregularity Index for epidemiological use
    Bernabe, Eduardo
    Flores-Mir, Carlos
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2006, 28 (03) : 269 - 273
  • [3] Phase transformation changes in thermocycled nickel-titanium orthodontic wires
    Berzins, David W.
    Roberts, Howard W.
    [J]. DENTAL MATERIALS, 2010, 26 (07) : 666 - 674
  • [4] Fatigue failure of as-received and retrieved NiTi orthodontic archwires
    Bourauel, C.
    Scharold, W.
    Jaeger, A.
    Eliades, T.
    [J]. DENTAL MATERIALS, 2008, 24 (08) : 1095 - 1101
  • [5] Surface characterization of retrieved NiTi orthodontic archwires
    Eliades, T
    Eliades, G
    Athanasiou, AE
    Bradley, TG
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2000, 22 (03) : 317 - 326
  • [6] Eliades T., 2001, ORTHODONTIC MAT SCI
  • [7] Ernst Claus-Peter, 2004, Clin Oral Investig, V8, P130
  • [8] Surface analysis of nickel-titanium archwire used in vivo
    Grimsdottir, MR
    Hensten-Pettersen, A
    [J]. DENTAL MATERIALS, 1997, 13 (03) : 163 - 167
  • [9] Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires having different transformation temperatures
    Iijima, M
    Ohno, H
    Kawashima, I
    Endo, K
    Mizoguchi, I
    [J]. DENTAL MATERIALS, 2002, 18 (01) : 88 - 93
  • [10] MECHANICAL-PROPERTIES AND CLINICAL-APPLICATIONS OF ORTHODONTIC WIRES
    KAPILA, S
    SACHDEVA, R
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1989, 96 (02) : 100 - 109